• 제목/요약/키워드: Tricuspid valve, replacement

검색결과 141건 처리시간 0.021초

선천성 삼첨판 협착증의 수술치험 1례 (Surgical Experience of Congenital Tricuspid Stenosis - A Report of Case -)

  • 김진국;안혁;오병희
    • Journal of Chest Surgery
    • /
    • 제21권4호
    • /
    • pp.700-705
    • /
    • 1988
  • A case of congenital tricuspid stenosis in 24 year old male patient is presented. The lesion was successfully corrected with prosthetic valve replacement and closure of atrial and ventricular septal defects. Especially, this is the first reported case of successful large prosthetic valve replacement to a small annulus in tricuspid valve.

  • PDF

심장다판치환술의 임상적 고찰 (Clinical Evaluation of Multiple Valve Replacement)

  • 오상기
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.160-166
    • /
    • 2000
  • Background: The purpose of this study is to evaluate and analyze the surgical results in patients undergoing operations for multiple for multiple valvular heart diseases. Material and method: From April 1982 to June 1997 multiple valve replacement was performed in 150 patients mitral and aortic valve replacement were done in 135 patients mitral and tricuspid valve replacements in 10 patients triple replacements in 4 patients and aortic and tricuspid valve replacement in 1 patient. Of the valves implanted 157 were St. Jude 104 Duromedics 20 Carpenter-Edwards 6 Bjork-Shiley 6 Ionescu-Shiley and 2 Medtronics. Result: The hospital mortality rate was 10.7% (16/150) and the late mortality rate was 7.2% (8/134) The mortality rate was high in early operative period but decreased with time. The causes of death were low cardiac output in 9 sudden death in 3 congestive heart failure in 3 bleeding in 2 cerebral thrombosis in 1 leukemia in 1 multiorgan failure in 1 and so on . The actuarial survival rate excluding operative death was 83.1% at 15 years. Conclusion: With a follow-up now extending to 15 years the multiple valve replacement continues to be reliable procedure with relatively low mortality and morbidity.

  • PDF

확장된 경중격 접근방식을 통한 승모판수술 (Mitral Valve Operation Via Extended Transseptal Approach)

  • 김학제
    • Journal of Chest Surgery
    • /
    • 제26권12호
    • /
    • pp.909-914
    • /
    • 1993
  • Complete and optimal visualization of the mitral apparatus is a prerequisite for accurate repair or replacement of the mitral valve. A vertical left atriotomy just posterior to the interatrial groove is the most commonly used approach. However,exposure can be difficult under certain circumstances,such as small left atrium or reoperation. Other approaches have been advocated to deal with this difficult situations. We used an extended transseptal approach in 10 patients and good clinical results and excellent educational effects were obtained. The extended transseptal approach combines two semicircular atrial incisions circumscribing the tricuspid and mitral annuli anteriorly and superiorly,allowing exposure of the mitral valve by deflecting the ventricular side using stay sutures. The right atrium is opened anteriorly along the atrioventricular sulcus. The atrial septum is incised vertically through the fossa ovalis. Right atrial and septal incisions are joined at the superior end of the interatrial septum and extended across the dome of the left atrium to the left atrial appendage. The mitral valve was replaced in all 10 patients. Four of 10 patients had other simultaneous valve procedure: one had aortic valve replacement: 2 underwent tricuspid annuloplasty: 1 had aortic valve replacement and tricuspid annuloplasty. There was no hospital death and complication. Among the 5 patients who had atrial fibrillation preoperatively,4 had atrial fibrillation postoperatively,1 converted to sinus rhythm. The five patients who were in normal sinus rhythm preoperatively remained in sinus rhythm after replacement. A review of our results with this approach confirms the efficacy and safty of this method. So we recommanded this approach for routine mitral valve procedure,especially difficult situations,such as a small left atrium or the redo operation.

  • PDF

후천성 삼첨판폐쇄부전증의 외과적 치료에 대한 연구 (Clinical Study of Surgical Treatment of Acquired Tricuspid Regurgitation)

  • 이형렬;김종원
    • Journal of Chest Surgery
    • /
    • 제26권3호
    • /
    • pp.196-203
    • /
    • 1993
  • Fourty-five cases of operation were performed for the correction of tricuspid regurgitation [TR] in Pusan National University Hospital between 1982 and 1991.The mean age of the patients was 32.6 years and female was dominant[M:F=1:2.2].Isolated tricuspid regurgitation was rare and 43 patients underwent concomitant other valvular operation including mitral valve replacement. Functional cause was in 39 cases and organic lesions were found in 6 cases. Operative methods were Kay annuloplasty[29], De Vega annuloplasty[12], and tricuspid valve replacement[4]. Ring annuloplasty was not performed. Operative mortality rate was 11.1%[5/45] and late mortality rate was 6.7%[2/30]. The tricuspid valve surgery itself was not a serious risk factor for hospital death and no heart block nor thrombosis was complicated. By echocardiogram early[within 30 days] and late [mean:4.9years] changes of postoperative TR were evaluated. De Vega annuloplasty seemed to bring better late result than Kay annuloplasty[p<0.05]. In four patients with late severe TR,previously replaced tissue valve degeneration[2], pulmonary hypertension[1] and rheumatic TR[1] were the possible causes. This experience suggests that De Vega annuloplasty can be a reliable method in the majority of patients with moderate-to-severe functional TR.

  • PDF

연간 개심술 416례 보고 [1980 년도] (Annual Open Heart Surgery: Report of 416 Cases in 1980)

  • 이영균
    • Journal of Chest Surgery
    • /
    • 제14권1호
    • /
    • pp.17-25
    • /
    • 1981
  • In 1980, 416 cases of open heart surgery were done in this Department with over all operative mortality of 12.3%. 1. There were 288 congenital anomalies consisting of 174 acyanotic and 114 cyanotic varieties, which showed operative mortality of 6.9% and 25.4% respectively. 2. There were 128 cases of acquired lesions, 124 valvular disease and 3 myxoma being the main lesions. 3. There were 128 cases of valve replacement with operative mortality of 7.8%. 4. The most frequently operated anomaly was VSD, 90 pure VSD and 21 cases were associated with one or 2 cardiac anomalies. Over all operative mortality in 111 VSD cases was 8.1% but in 90 pure VSD cases it was 6.7%. 5. Tetralogy of Fallot showed the highest incidence in cyanotic group with 88 cases, consisting of 68 pure and 20 with other cardiac anomalies. Over all mortality in 88 cases was 19.3% but in pure form 16.2%. 6. In 128 valve replacement cases over all mortality was 9.4%. There were 85 mitral, 11 aortic, 2 tricuspid, 21 mitral with aortic, 6 mitral with tricuspid, 3 mitral, aortic, and tricuspid valve replacement cases. For mitral valve replacement operative mortality was 5.9%. 7. Twenty-one cases of babies under 10kg body weight were operated on with over all operative mortality of 28.6%. Sixteen cases of VSD were found with operative mortality of 25%. 8. Among 128 cases of valve replacement 7 were under the age of 15 years and 12 were between 15 and 20 years old. Five pediatric cases underwent mitral valve replacement without mortality, 9 year old boy was the youngest among them. In this Department open heart surgery for infancy and complex anomalies showed still hip operative risk which should be improved in the coming years. For open heart surgery Shiley oxygenators and 2 sets of A-O de-lux 5 head roller pump were utilized exclusively. For valve replacement Ionescu-Shiley bovine pericardial xenografts were mainly used. In pediatric and rural patients Persantin with aspirin regimen was satisfactorily administered for anticoagulation after valve replacement. Routinely Coumadin was administered for one year after valve replacement* In patients who had thrombus on valve sites, chronic atrial fibrillation, and giant left atrium Persantin-Aspirin regimen was used when one year coumadin administration was discontinued.

  • PDF

삼첨판막폐쇄부전증을 동반한 활로씨 4 증후군[1예 보고] (Tricuspid Valve Insufficiency Complicating Tetralogy Of Fallot)

  • 조대윤
    • Journal of Chest Surgery
    • /
    • 제13권3호
    • /
    • pp.229-232
    • /
    • 1980
  • Approximately 5 percent of infective endocarditis are limited to the right side of the heart, the tricuspid valve being the usual site of involvement. Usually there is no underlying cardiac disease, and the vegetations occur on previously normal tricuspid leaflets. This paper reports a case of bacterial endocarditis involving the bio-tricuspid valve in a patient with tetralogy of Fallot, and who required prosthetic valve replacement in addition to surgical therapy for the congenital lesions.

  • PDF

Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im;Kyung Hwan Kim;Suk Ho Sohn;Yoonjin Kang;Ji Seong Kim;Jae Woong Choi
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.435-444
    • /
    • 2023
  • Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.

1978년도 상반기 개심술 : 112례 보고 (Open Heart Surgery in the First Half of 1978: A Report of 112 Cases)

  • 이영균
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.281-295
    • /
    • 1978
  • Last year in this department 100 cases of open heart surgery were done annually. This year 200 cases of open heart surgery were scheduled. During the first 6 months of this year 112 open heart surgery cases were done with 13 deaths [11.6%]. There were 72 cases of cougenital malformation with 9 operative deaths [12.5%], consisting of 23 acyanotic cases with one death [4.5%] and 49 cases of cyanotic cases with 8 deaths [16.3%]. Out of 40 tetralogy of Fallot, 6 cases expired [15%]. For 39 cases of acquired valvular heart disease and one Ebstein anomaly valves were replaced with 4 operative deaths [10%]. Single valve replacement in 33 with 3 operative deaths and double valve replacement in 7 cases with one death were noted. Two patients expired among 28 mitral valve replacement cases [7.1%]. Among 7 double valve replacement patients, consisting of 3 mitral and aortic and 4 mitral and tricuspid valve replacement one case expired. In a case of Ebstein anomaly, tricuspid valve was replaced with plication of atrialized right ventricle successfully. The operative result was excellent.

  • PDF

Permanent Pacemaker Lead Induced Severe Tricuspid Regurgitation in Patient Undergoing Multiple Valve Surgery

  • Lee, Jung Hee;Kim, Tae Ho;Kim, Wook Sung
    • Journal of Chest Surgery
    • /
    • 제48권2호
    • /
    • pp.129-133
    • /
    • 2015
  • Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.

승모판막 대치이식술 238예 보고 (Mitral Valve Replacement : A Report of 238 cases)

  • 이영균;양기민
    • Journal of Chest Surgery
    • /
    • 제13권4호
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF