• Title/Summary/Keyword: Tributary discharge and water quality monitoring

Search Result 9, Processing Time 0.021 seconds

Selection of Priority Management Target Tributary for Effective Watershed Management in Nam-River Mid-watershed (남강 중권역의 효율적인 유역관리를 위한 중점관리 대상지류 선정)

  • Jung, Kang-Young;Kim, Gyeong-Hoon;Lee, Jae-Woon;Lee, In Jung;Yoon, Jong-Su;Lee, Kyung-Lak;Im, Tae-Hyo
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.514-522
    • /
    • 2013
  • The major 24 tributaries in Nam-River mid-watershed were monitored for discharge and water quality in order to understand the characteristics of the watershed and to select the tributary catchment for improving water quality. According to the analytical results of discharge and water quality monitoring data of 24 tributaries, the mean value of discharge below $0.1m^3/s$ was 62.5% among the monitored tributaries and it mostly exceeded the water quality standards of Nam-river mid-watershed ($BOD_5$ = 3 mg/L, T-P = 0.1 mg/L over). According to the stream grouping method and the water quality delivery load density ($kg/day/km^2$) based on the results of tributary discharge and water quality monitoring, the tributary watersheds for improving the water quality were selected. In the Nam-River mid-watershed, tributaries in the GaJwaCheon, HaChonCheon catchment (Group D, $BOD_5$ = 3 mg/L over) and in the UirYeongCheon, SeokGyoCheon catchment (Group A, T-P = 0.1 mg/L over), which have a small flow (and/or large flow) and a high concentrations of water pollutants. The various water quality improving scheme for tributaries, in accordance with the reduction of potential point source pollution by living sewage and livestock wastewater, should be established and implemented.

Water Quality Improvement Plans based on the Analysis of Pollutant Discharge Characteristics and Water Quality Modelling of Seokmun Reservoir Watershed (석문호 유역 오염물질 배출특성 분석 및 수질모델링에 기초한 수질개선방안 연구)

  • Choi, Moojin;Jung, Woohyeuk;Choi, Jaehun;Kim, Youngil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.581-590
    • /
    • 2017
  • For effective improvement of water quality in Seokmun reservoir, this study implemented various analyses including the tributary water quality and flowrate monitoring, contamination of sediment, investigation of pollution source, selection of priority management target tributary by stream grouping method. The COD concentration of the majority of tributaries in Seokmun reservoir watershed was relatively higher than BOD concentration. The concentration of water pollutants regardless of water quality parameters in Yeokcheon, Dangjincheon, Sigokcheon, Baekseokcheon, small stream in Jinkwanri and Janghangri were higher than the other tributaries. The pollution sources in the Seokmun reservoir watershed were mostly distributed in the population, livestock, and industry. The pollutants, which located in Yeokcheon, Dangjincheon, Baekseokcheon, and small stream in Janghangri selected as priority management target tributary, should be preferentially reduced for improving the water quality in Seokmun reservoir. As the evaluation results of water quality in Seokmun reservoir for the effect of water quality improvement according to various scenarios using water quality model, it was found that the water quality in Seokmun reservoir due to the construction of a wastewater treatment plant for management of pollutants in the watershed would be satisfied the class V of water environment standard in reservoir.

Hydrochemical Characteristics and Changes by Rainfall in the Jungrang River (강우에 의한 중랑천의 수질 특성 변화 연구)

  • Kim, Youn-Tae;Kim, Yu Lee;Woo, Nam-Chil;Hyun, Seung Gyu
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.666-671
    • /
    • 2006
  • Effects of a rainfall event (July 28, 2005) on the hydrochemical characteristics of the Jungrang river, the biggest tributary of the Han river, was investigated. Significant spatial variations in the hydrochemical characteristics were observed. At JR2 location, concentrations of T-N and T-P were relatively low indicating occurrence of active oxidation in the stepped drop structure. At JR3 location, concentrations of Na, K, Cl, $NH_4-N$ and EC were elevated suggesting increased discharge from the nearby waste-water treatment plant and tributaries. The rain event diluted major dissolved ion concentrations in the river by 12~52%. The $NO_3-N$ levels were preserved during the rain then increased about twofold after rainfall, suggesting increased discharge of nitrate-contaminated groundwater. Heavy metals including Cd, Co, Cr, Cu and Pb were not detected in all water samples and the leachates from surface sediment samples. Concentrations of Fe, Mn, Al and Zn were below the Korean Drinking Water Guideline. Results of this study suggested that establishment of water-quality monitoring protocols describing temporal and spatial variations in parameters sensitive to rainfall events, relatively steady factors, and contaminant sources is required.

Evaluation of Pollutant loads at Inflow Streams under Ara Waterway Basin

  • Han, Sangyun;Jung, Jongtai
    • Journal of Urban Science
    • /
    • v.10 no.1
    • /
    • pp.39-48
    • /
    • 2021
  • In this study, to evaluate the characteristics of the pollution in the major inflow tributaries and major environmental facilities in the watershed of Ara waterway, An inflow flow rate measurement and water quality analysis were conducted during dry and rainy seasons. In addition, the flow rate measurement, water quality analysis, and pollutant load at each monitoring point were compared and evaluated. Influx of BOD5, T-P and T-N into the tributaries of the ARA waterway watershed, excluding the Gulpo river watershed, during dry season were only 0.007%, 0.005% and 0.004% respectively of the incoming loads in the entire ARA waterway basin. In addition, it was confirmed that the discharge pollutant loads during rainfall event was about 440 times more for BOD5, about 545 times on T-P, and about 23 times on T-N in comparison to the pollutant loads during the dry days. When the Gulhyeon rubber dam was deflated, the discharged pollutant load during a rainfall was higher than the estimated load at the G7 monitoring point because the deposited pollutants from the upstream riverbed flowed down. Therefore, during a rainy season, it is necessary to manage the influx of high-load water pollutants from the overflow and deflation of the Gulhyun rubber dam as well as to find a strategy to reduce the pollutant loads in the Gulpo river watershed.

Water Pollution Source Tracing Using FDC and Correlation Analysis in Geumho River Basin (FDC 및 상관관계 분석을 이용한 금호강 유역에서의 오염원추적)

  • Park, Kyung Ok;Lee, Chang Hee;Cha, Il Geun
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.232-243
    • /
    • 2016
  • In order to establish the watershed water quality management strategy of Total Maximum Daily Load(TMDL), it is necessary to understand the relationship between water quality component impacts, and to identify the impacts on downstream target point of watershed water quality management of waste treatment plant(WTP) discharge and upstream/tributary loads. In this study, we determined the impacts between the water quality contaminants, and traced water pollution sources using monitoring data of ministry of environment in tributaries and main stream and WTP monitoring data. Test area is set to Geumho river basin which has characteristics of urban and rural area and composes of GeumhoA, GeumhoB, GeumhoC watershed units in TMDL. The clustering with five grades of discharge data and the correlation analysis were performed through the FDC(Flow duration curve) analysis, which more clearly identified the points and water contaminants deteriorating target water quality of downstream point. This can be used as a tool for tracing pollutants with FDC analysis, and will help us establish the watershed water quality management strategy for TMDL target point in watershed more effectively.

A Study on the Assessment of Pollution Loads at Small Stream in Yeongsan River Watershed (영산강수계 소하천의 오염부하량 평가에 관한 연구)

  • Ha, Don-Woo;Shim, Hongbin;Kim, Haesung;Kim, Yoonsoo;Cho, Sohyun;Song, Chang-Soo;Kang, Taegu;Kim, Yeong-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, the load of the river was calculated by using the actual data of the Yeong-bon C1, Yeong-bon C2, Yeong-bon C3 monitoring points of the Yeong-san river watershed to determine the excess. As a result, the BOD is 75.83 % at the Yeong-bon C1 and the five-year average value is higher than at other points. The Yeong-bon C3 was 72.15 % and Yeong-bon C2 was analyzed as 68.78 %. The five-year average of the T-P was 71.95 % for the Yeong-bon C2 and 69.86 % for the Yeong-bon C3 and 69.16 % for Yeong-bon C1; these levels exceeded the target water quality standards of 50 %. As a result of analyzing the pollutant load, we found that the Yeong-bon C1 has been highly affected by the nonpoint pollution source because the excess rate is high in the upper section of the flow rate. The Yeong-bon C2 showed a high excess rate in the lower part of the flow rate, and it was estimated that the influence of the point pollution source was large. The excess rate of the Yeong-bon C3 is small in the interval deviation, and it was evaluated as being affected by both point and non-point pollution sources. The TMDL monitoring network data were used to estimate the exceed ratio for the target water quality assessment, and the implementation evaluation was made by the flow exceedance probability interval to analyze the monitoring data so that the data could be utilized according to the purpose of the measurement network.

Status and Causes of Cyanobacterial Blooming in the Downstream of Jecheon Stream (제천천 하류 지역에서 녹조 발생 현황 및 원인 분석)

  • Yu-Ho Jeon;Do-Hwan Kim;Kyoung-Hee Oh;Young-Cheol Cho
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.2
    • /
    • pp.111-119
    • /
    • 2022
  • The occurrence of cyanobacterial blooming and the contaminant sources were analyzed in the downstream of Jecheon Stream, a tributary of Chungju Reservoir. The concentrations of chlorophyll a at the Myungseo Fishing Point (GPS; 37°03'25.5"N, 128°03'13.6"E) were 399.2 and 184.8 mg m-3 on October 18, 2015 and September 25, 2016, respectively, and the concentrations of total microcystins, a cyanobacterial toxin mainly produced by Microcystis, were 124.09 and 79.71 ㎍ L-1, respectively. The occurrence of cyanobacterial blooming at the downstream of Jecheon Stream was closely related to the water level of Chungju Reservoir. The cyanobacterial blooming occurred after the increase of water level in Chungju Reservoir, when the water body stagnated. As a result of analyzing National Water Quality Monitoring Data of the upper region of Jecheon Stream, the main source of pollutant was Jangpyeong Stream, the tributary of Jecheon Stream, and the discharge water from Jecheon Wastewater Treatment Plant located in Jangpyeong Stream was considered to be the most important source of contaminant.

Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin (금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사)

  • Na, Seungmin;Kwon, Heongak;Kim, Gyeong Hoon;Shin, Dongseok;Im, Tae Hyo
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.363-377
    • /
    • 2016
  • This study was investigated the pollutant load, contamination properties, pollution condition of the fine parts of tributary, the influence of Nakdong river watershed and etc. in the tributaries. The contaminated tributaries were that among the Kumho and Nam river or were too far from site of water quality monitoring stations, regularly. As a result, the water quality level was almost similar between Nam and Kumho River, except for certain parameter including TN(Total Nitrogen), Chl-a(Chlorophyll-a) and SS(Suspended Solid) in which Kumho river were 20~120%. The point discharge load(kg/day) and load density ($kg/day/km^2$) of tributaries were different the pollution level according to the flow-rate ($m^3/sec$) and stream influence area($km^2$), and the difference of these was observed highly at Nam river. Specific contamination investigation of tributaries in Nam and Kumho river watershed was conducted from two to nine points of the fine parts of tributaries depending on the confluence sites and shapes. This result observed high at the Dalseocheon and Uriyeongcheon, respectively. Beside, the pollutant load contribution rate of Nakdong watershed was high about 10% at the Dalseocheon and Uiryeongcheon. This was due to the differences of the environments about the industrial complex, metropolis residence property, agricultural cultivation, livestock pen and the downstream of non-point source.

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.