• 제목/요약/키워드: Triangular groove

검색결과 27건 처리시간 0.022초

삼각피판법을 이용한 편측 불완전 구순열 환자의 구순 교정 수술-증례 보고 (Repair of the Cleft Lip using Triangular Cheiloplasty-A Case Report)

  • 송인석;홍종락;정필훈;서병무
    • 대한구순구개열학회지
    • /
    • 제10권2호
    • /
    • pp.67-74
    • /
    • 2007
  • After Tennison introduced a triangular flap method which, for the first time, preserved the Cupid's bow, Randall gave this method a sound mathematical basis. This method is also called as an inferior triangular cheiloplasty which is characterized by making a small triangular flap from the lateral border of cleft destined to be fitted into an incision on the medial side of cleft. He postulated that the height obtained was equal to the sum of the median of the two triangles used in the cheiloplasty. Using this technique, a 22 month-old male patient with incomplete unilateral cleft lip was corrected primarily. The deviation of the columella and flattening of the nostril on the cleft side were minimal. The operation was done under general anesthesia and patient was healed uneventfully. We tried to improve the symmetry and esthetic feature of philtrum, nostril sill, alar-facial groove, preventing the notch formation on the nostril floor, and to reconstruct the muscle sling in the upper part of lip. The shape of Cupid's bow was restored, and the symmetry of columella was regained as a result. In summary, the inferior triangular cheiloplasty is effective to correct the primary unilateral cleft lip, results in the restoration of favorable anatomy and function.

  • PDF

유압용 액셜 피스톤 펌프의 유량맥동 계측에 관한 연구 (A Study on the Measurement of Delivery Flow Ripple Generated by Hydraulic Axial Piston Pumps)

  • 이상기
    • 한국생산제조학회지
    • /
    • 제8권2호
    • /
    • pp.35-43
    • /
    • 1999
  • The paper describes an approach for measuring delivery flow ripple generated by oil hydraulic axial piston pumps. In order to reduce pressure ripple which cause to undesirable noise. vibration and fatigue in hydraulic systems it is indispensible measure a delivery flow ripple from pumps. Since the flow ripple measurement of flow pumps is independent of the dynamic characteristics of the connected hydraulic circuit the measurement of flow ripple is most suitable for pump fluid-borne noise rating. The measurement of flow ripple with high frequencies from axial piston pumps is made by applying the remote instantaneous flow rate measurement method which is based on the dynamic characteristics between pressure and flow rate in hydraulic pipeline. The measured flow ripple waveforms are influenced by the configuration of V-shaped triangular relief groove in the valve plate. It can be seen that the appropriate relief groove in valve plate reduces the pressure and flow ripple amplitude and frequency spectrum for high harmonics.

  • PDF

Gynogonadinium aequatoriale gen. et sp. nov., a New Dinoflagellate from the Open Western Equatorial Pacific

  • Gomez, Fernando
    • ALGAE
    • /
    • 제22권1호
    • /
    • pp.11-15
    • /
    • 2007
  • A new genus and species of marine dinoflagellate from the open western equatorial Pacific Ocean, Gynogonadinium aequatoriale gen. et nov. sp., is described from light and scanning electron micrographs. This laterally compressed unarmoured taxon had a triangular cell body in lateral view with two different elongate extensions. The end of the apical extension was spherical with a groove that arises from the epicone in the ventral side of the cell. The antapical extension was longer. The dorsal part of the cingulum showed undulated lists in each margin. The nucleus was ellipsoidal and perpendicularly crossed the cingulum. Dimensions of cells were 90-110 μm long and 43-55 μm wide in lateral view at the level of the cingulum. Gynogonadinium is placed in the order Gymnodiniales, family uncertain.

사다리꼴 모양의 돌기나 V형 홈을 갖는 형상 환상압연에 대한 UBET 해석 (Analysis of profile ring rolling for rings having V-groove of trapezoidal protrusion by the upper-bound elemental technique)

  • 한영호;양동열
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.40-47
    • /
    • 1993
  • To diversify the area of application of UBET to the analysis of ring rolling which produces rings having more complex cross-sectional configuration, an element of triangular cross-section has been introduced and the corresponding kinematically admissible velocity field has been derived while considering the material flow between neighboring elements. The theoretical perdictions in roll torque and profile formation show good agreement with the experiments. The effect of process parameters such as feed rate and taper angle of the roll groove has been discussed.

  • PDF

점적관개용 디스크 여과기의 디스크 홈 단면 형상에 따른 수두 손실 특성 분석 (Analysis of Disk Filter Head Losses due to the Shapes of Disk Grooves in Drip Irrigation System)

  • 정승연;최원;최진용;김마가;이윤희
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.25-36
    • /
    • 2018
  • Drip irrigation system is a low energy cost method which can efficiently save and supply water by dropping water slowly on the crop's root zone during crop growth. In the drip irrigation system, disk filters take an important role to physically remove impurity (inorganic and suspended organic) particles present in agricultural water which can cause emitter clogging. For the purpose, both top-and-bottom surfaces of the disk are grooved in micron size flowing from outside to inside. However, many congested flow paths in disk filter media incur higher head loss of inflow water resulting in relatively decreasing velocities depending on operation time than sand and mesh filters. Therefore, it is important to optimize the structure of disk filter in micro irrigation system. The head loss of disk filter media takes also charge of more than 60 % of total head loss in whole disk filter. This study is to find the appropriate cross-sectional shape of the disk groove to minimize the head loss by executing the experiment. The experiment used three disk filters that have similar filter body but have a half-elliptic and two kinds of triangular cross sections. The experimental results showed that the disk filter with half-elliptic cross sections of disk grooves have less head loss than the disk filter with regular triangular one.

단결정 다이아몬드공구를 사용한 Cu 도금된 몰드의 미세 구조체 가공특성 (Machining Characteristics of Micro Structure using Single-Crystal Diamond Tool on Cu-plated Mold)

  • 김창의;전은채;제태진;강명창
    • 한국분말재료학회지
    • /
    • 제22권3호
    • /
    • pp.169-174
    • /
    • 2015
  • The optical film for light luminance improvement of BLU that is used in LCD/LED and retro-reflective film is used as luminous sign consist of square and triangular pyramid structure pattern based on V-shape micro prism pattern. In this study, we analyzed machining characteristics of Cu-plated flat mold by shaping with diamond tool. First, cutting conditions were optimizing as V-groove machining for the experiment of micro prism structure mold machining with prism pattern shape, cutting force and roughness. Second, the micro prism structure such as square and triangular pyramid pattern were machined by cross machining method with optimizing cutting conditions. Burr and chip shape were discussed with material properties and machining method.

Fine Structural Analysis on the Dry Adhesion System of the Jumping Spider Plexippus setipes (Araneae: Salticidae)

  • Moon, Myung-Jin;Park, Jong-Gu
    • Animal cells and systems
    • /
    • 제13권2호
    • /
    • pp.161-167
    • /
    • 2009
  • The cuticle of spider's exoskeleton is a hydrophobic and non-adhesive material, but the jumping spiders have the distinctive attachment apparatus for adhesion on smooth dry surface without sticky fluids. We have examined the whole tarsal appendages of the jumping spider, Plexippus setipes with using scanning electron microscope to reveal the fine structural characteristics of the dry adhesion system. All eight legs have the scopulae with a pair of claws on the tip of feet. Each scopula is composed of two groups of setae that are capable of dry adhesion on smooth surface, and the hook structure of the claw is advanced to move on the rough surface. The setae toward the bottom of the tarsal segment are densely covered by numerous setules on the underside which broadened from middle to distal portion. It has been revealed by this research that the contact area of the setule is always a triangular shape, and these cuticular surfaces are connected by the elongated stalks from the underlying setae. It is likely that the nano-scale structures including a triangular depression and a longitudinal groove on each setule could functionate when the spider detach its feet from the substrate.

영상처리식 온라인 품위판정을 위한 현미의 정렬공급장치 (Echelon Feeder of Brown Rice for On-line Inspection Using Image Processing)

  • 김태민;노상하
    • Journal of Biosystems Engineering
    • /
    • 제35권3호
    • /
    • pp.197-205
    • /
    • 2010
  • An automatic echelon feeder of brown rice was presented for quality inspection system using color image processing. A echelon feeder was developed with vibratory feeder and cylindrical indent singulator having oblique light. The vibratory feeder consisted of a hopper, electromagnetic vibrator and multichannel grooves and supply the grain sample to the singulator. The feeding performance such as feed rate, blocking frequency of the channel was dependent on the size of groove and vibration pattern. A cylindrical indent singulator consisted of a rotating cylinder, prisms and a tungsten-halogen light source. It delivered grain kernels under the camera in a echelon form and illuminate the kernels with oblique ray and ambient light. The size of the indents installed on the surface of the rotating cylinder was determined by the dimensions of the paddy and a small triangular prism was placed in each indent to apply $ 20^{\circ}$ oblique light to the grain kernel.

판형 열교환기의 맥동유동에 의한 열전달 향상에 관한 수치해석연구 (A NUMERICAL STUDY ON HEAT TRANSFER ENHANCEMENT BY PULSATILE FLOW IN A PLATE HEAT EXCHANGER)

  • 이명성;허남건;강병하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.93-96
    • /
    • 2006
  • The heat transfer enhancement by pulsatile flow in the plate heat exchanger has been investigated numerically in the present study. The numerical study was performed in the range of the mass flux from 0.04 to 0.12 kg/s. The results showed that the pulsatile flow produces resonating vortex shedding at the groove sharp edges and a strong transient vortex rotation within the grooved channels. As a result, the mixing between the trapped volume in the grooved cavity and the main stream was enhanced. Good agreements between the predictions and measured data are obtained in steady flow. And the heat transfer of pulsatile flow is about 2.4 times than steady flow when frequency is 10 Hz and the mass flux of cold side is 0.04 kg/s.

  • PDF

맥동유동에 의한 판형열교환기의 열전달 성능 향상에 관한 수치연구 (A Numerical Study on Heat Transfer Enhancement by Pulsatile Flow in a Plate Heat Exchanger)

  • 진상문;박종택;허남건;강병하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.85-90
    • /
    • 2005
  • The heat transfer enhancement by pulsatile flow in plate heat exchanger has been investigated numerically in the present study. The numerical study was performed ill the range of the Strouhal number from 0.04 to 2 and the Reynolds number from 370 to 730. The results showed that the pulsatile flow produces resonating vortex shedding at the groove sharp edges and a strong transient vortex rotation within the grooved channels. As a result, the mixing between the trapped volume in the grooved cavity and the main stream was enhanced. Good agreements between the predictions and measured data are obtained for the optimum frequency of pulsation and corresponding heat transfer enhancement

  • PDF