• 제목/요약/키워드: Triac-SCR

검색결과 4건 처리시간 0.021초

SCR 및 TRIAC PSPICE 모델에 관한 연구 (A Study on a PSPICE Model for the SCR and TRIAC)

  • 원충연;양승호;김세찬;김덕헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.357-361
    • /
    • 1990
  • PSPICE is a general purpose circuit program that can be applied to simulate and calculate the performance of electronic circuits. More recently, an ideal voltage controlled switch provided in it is proposed to develop simple computer models for SCR's and TRIAC's. These models enable designer to simulate the steady state and transient analysis of power electronics circuit.

  • PDF

Triac을 이용한 삼상유도전동기의 일차전압평형제어에 따른 특성 연구 (A study on characteristics of three phase induction motor with stator voltage control by symmetrically triggered triacs)

  • 노창주;유춘식;정경열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.72-84
    • /
    • 1984
  • In this paper, the characteristics relating to the stator voltage control of a small three phase squirrel cage induction motor by means of symmetrically trggered triacs instead of antiparallel SCR's is described. A complete model of the system with 220V, $3{\phi}$, 1HP motor and triac gate control circuit has been designed and tested in the laboratory, and the experimental results are compared with the numerical values. As a result of the above investigation, it is found that the range of induction motor speed control by stator voltage control is narrow.

  • PDF

Help of Microcontroller on Voltage Control to Reduce Transformer Inrush Current

  • Fard, Ali Asghar Fathollahi
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권1호
    • /
    • pp.12-15
    • /
    • 2014
  • At the moment of transformer energization by the supply voltage, a high current called transient inrush current, which may rise to ten times the transformer full load current, could be drawn by the primary winding. This paper discusses a microcontroller circuit with the intention of controlling and limiting the inrush current for a transformer, by the method of ramping up the supply voltage feeding to the transformer primary. Simulations and the experimental results show a significant reduction of inrush current, when the ramping up voltage is applied to the three-phase transformer load. The inrush current could be almost eliminated if the correct switching step rate is chosen.

파형추적기술을 이용한 전자기기 고장진단용 회로분석기 설계 및 구현 (Design and Implementation of Circuit Analyzer for Electronics Appliance Troubleshooting and Diagnosis using Curve Tracer Technology)

  • 장재철;양규식
    • 한국정보통신학회논문지
    • /
    • 제3권2호
    • /
    • pp.273-280
    • /
    • 1999
  • 본 논문에서는 아나로그 파형분석의 파형추적기술을 이용하여 전자기기의 고장진단을 용이하게 할 수 있는 회로분석 시스템을 설계하고 구현하였다. 회로분석기는 CMOS, MOS 회로와 같은 신기술 전자부품들을 간단하게 검사할 수 있는 개선된 능력을 가지며, 내장된 펄스 구동기를 사용하여 SCR, TRIAC 그리고 Optocoupler와 같은 게이트 구동소자들을 고장진단하게 한다. 회로분석기는 측정하고자 하는 부품 및 기판에 전원을 인가하지 않고 측정하도록 하여 측정하는 중에 발생 가능성 있는 일시적인 Short로 인한 회로의 추가적인 손상을 방지하고 반도체소자의 임피던스 상태를 분석하며 시스템 또는 PCB기판의 영구적인 고장을 일으키는 누액 또는 기판손상으로 인한 문제를 완벽하게 찾아낼 수 있었다. 이상이 의심되는 부품과 정상 부품간의 상호 비교할 수 있기 때문에 부품 식별 번호가 없거나 알아보기 힘든 부품의 고장진단에 이상적으로 응용할 수 있는 방안을 제시하도록 한다.

  • PDF