• Title/Summary/Keyword: Treatment volume

Search Result 2,993, Processing Time 0.029 seconds

The Surface Sealing Performance of Film, Air cap and Polystyrene foam for Preventing Carbonation of High-Volume Slag Concrete (고로슬래그 미분말 다량치환 콘크리트의 탄산화 억제를 위한 기밀성 향상재 부착효과)

  • Han, Dongyeop;Kim, Kyunghoon;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • The goal of this research was evaluating and suggesting the solution of preventing carbonation of concrete replaced high-volume of slag. The concrete mixtures were prepared with high-volume slag and recycled aggregate, and the concrete samples were evaluated the carbonation depth with various surface treatment methods. For various surface treatment methods and surface protecting sheets, bonding strength and carbonation depth were measured. Basically, from the results, the carbonation of concrete was completely prevented with any type of surface treatment method and surface protecting sheet as far as the surface treatment materials were remained. Therefore, in this research, it was known and suggested that the easiness of handling and sufficient bonding performance was much important than the quality of surface protecting sheets.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Bladder filling variations during concurrent chemotherapy and pelvic radiotherapy in rectal cancer patients: early experience of bladder volume assessment using ultrasound scanner

  • Chang, Jee Suk;Yoon, Hong In;Cha, Hye Jung;Chung, Yoonsun;Cho, Yeona;Keum, Ki Chang;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • v.31 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: To describe the early experience of analyzing variations and time trends in bladder volume of the rectal cancer patients who received bladder ultrasound scan. Materials and Methods: We identified 20 consecutive rectal cancer patients who received whole pelvic radiotherapy (RT) and bladder ultrasound scan between February and April 2012. Before simulation and during the entire course of treatment, patients were scanned with portable automated ultrasonic bladder scanner, 5 times consecutively, and the median value was reported. Then a radiation oncologist contoured the bladder inner wall shown on simulation computed tomography (CT) and calculated its volume. Results: Before simulation, the median bladder volume measured using simulation CT and bladder ultrasound scan was 427 mL (range, 74 to 1,172 mL) and 417 mL (range, 147 to 1,245 mL), respectively. There was strong linear correlation (R = 0.93, p < 0.001) between the two results. During the course of treatment, there were wide variations in the bladder volume and every time, measurements were below the baseline with statistical significance (12/16). At 6 weeks after RT, the median volume was reduced by 59.3% to 175 mL. Compared to the baseline, bladder volume was reduced by 38% or 161 mL on average every week for 6 weeks. Conclusion: To our knowledge, this study is the first to prove that there are bladder volume variations and a reduction in bladder volume in rectal cancer patients. Moreover, our results will serve as the basis for implementation of bladder training to patients receiving RT with full bladder.

Intensity Modulation in Radiation Therapy (선량강도 조절법을 이용한 방사선치료)

  • 김성규;김명세
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.27-34
    • /
    • 1997
  • In radiation therapy, the goal of three dimensional conformal radiation therapy(3DCRT) is to conform the apatial distribution of the prescribed radiation dose to the precise 3D configuration of the tomor, and at the same time, to minimize the dose to the surrounding normal tissues. To optimize treatment volume of tomor, treatment volume will be same tomor volume. Biological considerations need to be incorporated in the intensity modulation optimization process. Planning of intensity modulated treatment can irradiate more 20% in tomor compare to conventional 3DCRT. In lung cancer and rectal cancer, planning of intensity modulated treatment showed optimizing dose distribution.

  • PDF

Central Diabetes Insipidus. A Case Report (중추성 요붕증 1례)

  • 이병철;장원만;안영민;안세영;두호경
    • The Journal of Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.99-102
    • /
    • 2000
  • Central diabetes insipidus(CDI) results from deficient vasopressin(antidiuretic hormone) secretion and causes polydipsia and polyuria. Its etiologic diagnosis is confirmed with an increase of urine osmolality by administering desmopressin(DDAVP) after water restriction. Because cm is caused by deficiency of vasopressin, up to now, desmopressin, a synthetic analog of vasopressin, has been the drug of choice in the treatment of CDI. However, under such treatment, CDI patients suffer from the continual administration of DDAVP throughout one's life and high cost of the treatment We administrated oriental herb medicine on a cm patient in a state of discontinuance of DDAVP. Prior to the study, brain sella MRI was scanned to exclude germinoma. In addition, urine analysis, serum and urinary osmolality, daily urinary volume, serum electrolyte levels were measured. Chungsimyunjatang was administered for 15 days, and urine analysis, urine osmolality, daily urinary volume, serum Na were measured several times again during the therapy, As a result, urinary frequency increased, serum Na slightly elevated, but specific gravity of urine, urinary osmolality severely decreased and daily urinary volume substantially increased. However, the frequency of DDAVP treatment was reduced from four times per day to once or twice a day with the continual administration of the Chungsimyunja-tang for two months after the discharge.

  • PDF

Effects of Aromatherapy Massage on Edema Reduction in the Treatment of Lymphedema (아로마 마사지가 림프부종에 미치는 영향)

  • Kim, Sung-Joong;Shim, Jung-Myo;Park, Yong-Deok
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study was to determine whether aromatherapy massages with manual lymph drainage (MLD) are significantly more effective than sham massages with MLD in reducing edematous limb volume in lymphedema. This study was performed on 46 patients who had developed unilateral upper or lower lymphedema. Twenty-three patients served as the experimental group and were treated with complex decongestive physiotherapy (CDP) applications including aroma massages with MLD, multi layered compression bandages, remedial exercises and skin care. Twenty-three patients in the control group were treated with CDP applications including sham massages with MLD, bandages, exercises and skin care. Patients undergo a therapy program once a day; 5 days a week for 2 weeks. Percentage excess volume (PEV) and body mass index (BMI) were recorded before and after treatment. PEV and BMI were significantly decreased before and after treatment in the experimental as well as in the control groups (p<.05). However, the percentage excess volume and BMI were not significantly improved after treatment between the two groups (p>.05). This study there suggests that aroma massages is not effective in the edema of patients with lymphedema.

  • PDF

The Retrospective Analysis of Obesity and Overweight Female Patients with Clinical Treatment including Herbal Medicine (비만 및 과체중 여성 환자에서 한약 처방의 치료 효과에 대한 후향적 분석)

  • Choi, Hyeon;Seo, Gi-Seong;Shin, Won-Yong
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.3
    • /
    • pp.35-46
    • /
    • 2016
  • Objectives: The aim of this study was to investigate the effect of herbal medicine on obesity and overweight female patients and to gather the information of a proper treatment goal for anti-obesity program in Korean medicine clinic.Methods: 230 subjects were recruited and those data were analyzed for body-mass index (BMI), treatment duration, weight, body fat, muscle volume and body fat/weight loss ratio. It was compared among age groups and severity of obesity.Results: It was achieved to loss 12-13 kg for 105.8 days thru obesity program of Korean medicine clinic. There were no significant differences for BMI loss, weight loss, body fat loss, muscle volume gain and treatment duration among age groups. It was found that there were significant differences among overweight, obesity and severe obesity group for BMI loss, weight loss, body fat loss and muscle volume gain except treatment duration. It was assumed the weight loss for 1 month was 3.2 kg, 4.2 kg, 4.5 kg for each severity group respectively.Conclusions: It was found herbal medicine treatment would be effective for female obesity and expected the patients could achieve 12-13 kg weight loss for 15 weeks treatment including 8-12 weeks herbal medicine administration and BMI loss per month could be 1.22 kg/m2, 1.60 kg/m2 and 1.70 kg/m2 for severity of obesity respectively. Hereafter, further controlled study with more numbers of patients should be needed to determine the goal of medical treatment for obesity.

The Evaluation of Effect Indicators on Estimation of Aeration Volume for Wastewater Treatment Plants (하수처리장 송풍량 산정에 미치는 영향 인자들의 평가)

  • Kim, Byoung Soo;Choi, Mi Young;Kwon, Hyuck;Kim, Jin Man;Cha, Woon Ou;Chun, Wan Myung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • To construct the system controlling the aeration volume for D wastewater treatment plant effectively, the fluctuation of aeration volume was analyzed with changes of factors of the influent. As a result, the range of aeration volume was wide to maintain the certain concentration of DO, and the key factor to decide the aeration volume was found to be the temperature, F/M ratio, the loading rate of $BOD_5$ and T-N of the influent. Among the factors, the temperature of the influent had the most decisive effect on the aeration volume. The result showed that $45.8m^3/h$ of the aeration volume was needed with an increase of $1^{\circ}C$ of the influent, and the effect of the season was considered. Since the temperature of the influent is affected by a change of season, same as F/M ratio, the loading rate of the influent and the concentration of MLSS, it seemed that the change of the temperature of the influent affects the aeration volume even more. Therefore, it is preferable to consider the loading rate of the influent and F/M ratio altogether, rather than considering only one factor when deciding aeration volume.

Evaluation of the Radiation Pneumonia Development Risk in Lung Cancer Cases

  • Yilmaz, Sercan;Adas, Yasemin Guzle;Hicsonmez, Ayse;Andrieu, Meltem Nalca;Akyurek, Serap;Gokce, Saban Cakir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7371-7375
    • /
    • 2014
  • Background: Concurrent chemo-radiotherapy is the recommended standard treatment modality for patients with locally advanced lung cancer. The purpose of three-dimensional conformal radiotherapy (3DCRT) is to minimize normal tissue damage while a high dose can be delivered to the tumor. The most common dose limiting side effect of thoracic RT is radiation pneumonia (RP). In this study we evaluated the relationship between dose-volume histogram parameters and radiation pneumonitis. This study targeted prediction of the possible development of RP and evaluation of the relationship between dose-volume histogram (DVH) parameters and RP in patients undergoing 3DCRT. Materials and Methods: DVHs of 41 lung cancer patients treated with 3DCRT were evaluated with respect to the development of grade ${\geq}2$ RP by excluding gross tumor volume (GTV) and planned target volume (PTV) from total (TL) and ipsilateral (IPSI) lung volume. Results: Were admitted statistically significant for p<0.05. Conclusions: The cut-off values for V5, V13, V20, V30, V45 and the mean dose of TL-GTV; and V13, V20,V30 and the mean dose of TL-PTV were statistically significant for the development of Grade ${\geq}2$ RP. No statistically significant results related to the development of Grade ${\geq}2$ RP were observed for the ipsilateral lung and the evaluation of PTV volume. A controlled and careful evaluation of the dose-volume histograms is important to assess Grade ${\geq}2$ RP development of the lung cancer patients treated with concurrent chemo-radiotherapy. In the light of the obtained data it can be said that RP development may be avoided by the proper analysis of the dose volume histograms and the application of optimal treatment plans.

Direct Decomposition of Nitrous Oxide over Fe-beta Zeolite (Fe-베타제올라이트 상에서 아산화질소의 직접분해반응)

  • Park, Jung-Hyun;Jeon, Seong-Hee;Khoa, Nguyen Van;Shin, Chae-Ho
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.122-129
    • /
    • 2009
  • The effect of calcination temperature or hydrothermal treatment of commercial Fe-beta zeolites in the range of $450{\sim}900^{\circ}C$ were examined in the direct decomposition of $N_2O$. Fe-beta zeolites used were characterized using XRD, $N_2$ sorption, $^{27}Al$ MAS NMR and XPS. Although the surface area and micropore volume of Fe-beta zeolite after calcination at $900^{\circ}C$ and hydrothermal treatment at $750^{\circ}C$ decreased ca. 30%, a larger decrease in the surface area and micropore volume by hydrothermal treatment was observed than by calcination treatment alone. However, the Al sites in frameworks of zeolite were conserved in stable tetrahedral form resulting from low degree of dealumination which was related to the adjacent Fe ions on the Al sites. This could likely be correlated with the conservation of high surface area and micropore volume of Fe-beta zeolites. The increase in the calcination or hydrothermal treatment temperature caused the increase of decomposition temperature of $N_2O$ and the severe deactivation was observed after hydrothermal treatment than calcination treatment.