• 제목/요약/키워드: Treatment efficiency of organic matter

검색결과 221건 처리시간 0.028초

정수처리 과정에서의 중금속제거에 관한 연구 (Removal of Heavy Metals Through Conventional Water Treatment Processes)

  • 김중구;고영송;남상호
    • 한국환경보건학회지
    • /
    • 제20권4호
    • /
    • pp.36-44
    • /
    • 1994
  • A study was carried out in order to investigate the removal efficiencies and removal characteristics of heaw metals such as Pb, Cd, Cr, Cu in raw water by one of conventional water treatment processes. The coagulants used in this study were Alum and PAC. Three kinds of water samples were provided: kaolin water, kaolin water mixed with humic acid and raw water from Han River mixed with suspended matter deposited on raw water inlet pipe. Heaw metals were added to the water samples with their respective turbidity, and jar tests were performed. In the results from heaw metal removal studies, lead might be adsorbed or exchanged on the particle surface (SS) rather than react with organic matter added. Cadmium was affected on the dissolved organic matter. Chromium was affected by the both dissolved organic matter and SS concentration, and the restabilization and the enmeshment appeared at moderate (50~80 NTU) and high (100 NTU) turbidity as defined in this experimenL The removal efficiency of copper was relatively little affected by the dissolved organic matter but by SS concentration in comparison with other heavy metals. In these studies as to the raw water turbidities and concentration of heaw metals, it is proved out that the removal efficiency on heaw metals in both cases of PAC and Alum as coagulants was not significantly different.

  • PDF

하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동 (Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents)

  • 한지희;손진식
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

$MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명 (Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process)

  • 손희종;황영도;노재순;정철우;강임석
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.753-761
    • /
    • 2005
  • 전처리 공정에 따른 투과 flux 변화를 살펴보면 $MIEX^{(R)}$+UF 공정의 경우 응집+UF 공정에 비하여 높은 유기물 제거율을 나타내었으나 투과 flux 감소는 크게 나타났다. 따라서, 막 오염을 자세하게 규명하기 위하여 sequential filtration 실험결과 막 오염물질은 고분자 유기물질로 나타났으며, DOC 0.5 mg/L 이하의 유기물질이 막 오염 유발물질로 작용하고 있었다. 10 kDa 이하의 저분자 유기물질들은 $MIEX^{(R)}$ 처리에 의해 제거가 용이하여 막 표면에서 유기물 부하를 감소시켜 이로 인해 응집+UF공정에 비하여 투과 flux 감소율이 낮게 나타났다. $MIEX^{(R)}$+UF공정은 입자상 물질의 존재 유무에 관계없이 flux 감소율은 거의 유사한 경향을 보였으나 응집+UF공정은 용존성 유기물질만이 존재하는 시수에 비하여 입자상 물질이 존재하는 경우에 투과 flux 감소가 더 낮게 나타났다.

팔당호와 팔당호 상류의 난분해성 유기물질 유출 특성 분석 및 상관성 분석 (Analysis of Non-Biodegradable Organic Matter Leakage Characteristics and Correlation Analysis in Paldang Lake and its Upper Reaches)

  • 강채원;길경익
    • 한국습지학회지
    • /
    • 제25권4호
    • /
    • pp.221-229
    • /
    • 2023
  • 수도권에 일 약 8백만톤의 물을 취수하여 공급하는 팔당호는 수질보전정책 시행으로 BOD(Biochemical Oxygen Demand)1.1mg/L를 달성하였으나 난분해성 물질을 포함하는 COD(Chemical Oxygen Demand) 항목은 점점 증가하는 양상을 보였다. 난분해성 유기물질의 상수원 유입은 잠재적인 BOD의 증가, 수돗물의 냄새와 맛 유발, THM(Trihalomethane) 발생 증가, 조류 증식을 일으키며 유해 난분해성 미량오염물질이 잔류할 경우 수생 환경에서 내분비 교란과 항생제 내성과 같은 현상을 유발한다. 본 연구에서는 팔당호의 난분해성 유기물질 관리를 위해 팔당호와 팔당호 상류의 점 오염원과 비점오염원의 난분해성 유기물질 유출 농도를 파악하기 위한 모니터링을 실시하였다. 지역별 난분해성 유기물질 유출 농도를 비교하고 하수처리장에서의 제거율을 파악하였다. 또한 피어슨 상관성 분석 기법을 사용해 유기물질 지표와 선행건기일수, 선·선행건기일수간 상관성 분석을 실시하였다. 하천과 팔당호의 난분해성 유기물질 농도는 유사한 양상을 보였다. 하수처리장 유출수는 하천과 팔당호보다는 높은 농도를 보였으며, 유입수와 유출수 농도의 비교 결과 하수처리장에서 난분해성 유기물질 제거율은 65.73%였다. 난분해성 유기물질 유출 농도와 선행건기일수, 선·선행건기일수 사이에서는 유의미한 상관성이 나타나지 않았다. 이는 데이터 부족으로 판단되며 장기적인 모니터링으로 데이터 축적이 필요하다 사료된다.

변형 연속회분식 반응기를 이용한 오수의 고도처리 (Advanced Sewage Treatment by the Modified SBR(Sequencing Batch Reactor) Process)

  • 김병군;서인석;홍성택;정위득
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.46-51
    • /
    • 2002
  • This study was performed to treat a sewage at the upper stream of dam using modified sequencing batch reactor, During the operating period, average $COD_{cr}$, removal efficiency was about 85% but average T-N and ${PO_4}^{3-}-P$ removal efficiencies were 43% and 30% respectively. Because the organic matter was very low compared with nitrogen and phosphorous in influent($BOD_{5}/{NH_4}^{+}-N{\;}={\;}2,{\;}BOD_{5}/{PO_4}^{3-}-P{\;}={\;}15.6$), nitrogen and phosphorus removal efficiency was relatively low. Average nitrogen removal efficiency was 50 % at $10^{\circ}C$ or above and it was 36 % at $10^{\circ}C$ or below. As reactor was located in outdoor without any thermostat, temperature decreased at least $2.4^{\circ}C$ in the winter season. Therefore, if we would apply this modified sequencing batch reactor to sewage which concentration of organic matter was very low compared with nitrogen and phosphorous, we have to addition of external carbon and installation of any thermostat.

Dissolved organic matter characteristics and bacteriological changes during phosphorus removal using ladle furnace slag

  • Noh, Jin H.;Lee, Sang-Hyup;Choi, Jae-Woo;Maeng, Sung Kyu
    • Membrane and Water Treatment
    • /
    • 제9권3호
    • /
    • pp.181-188
    • /
    • 2018
  • A sidestream contains the filtrate or concentrate from the belt filter press, filter backwash and supernatant from sludge digesters. The sidestream flow, which heads back into the sewage treatment train, is about 1-3% less than the influent flow. However, the sidestream can increase the nutrient load since it contains high concentrations of phosphorus and nitrogen. In this study, the removal of PO4-P with organic matter characteristics and bacteriological changes during the sidestream treatment via ladle furnace (LF) slag was investigated. The sidestream used in this study consisted of 11-14% PO4-P and 3.2-3.6% soluble chemical oxygen demand in influent loading rates. LF slag, which had a relatively high $Ca^{2+}$ release compared to other slags, was used to remove $PO_4-P$ from the sidestream. The phosphate removal rates increased as the slag particle size decreased 19.1% (2.0-4.0 mm, 25.2% (1.0-2.0 mm) and 79.9% (0.5-1.0 mm). The removal rates of dissolved organic carbon, soluble chemical oxygen demand, color and aromatic organic matter ($UV_{254}$) were 17.6, 41.7, 90.2 and 77.3%, respectively. Fluorescence excitation-emission matrices and liquid chromatography-organic carbon detection demonstrated that the sidestream treatment via LF slag was effective in the removal of biopolymers. However, the removal of dissolved organic matter was not significant during the treatment. The intact bacterial biomass decreased from $1.64{\times}10^8cells/mL$ to $1.05{\times}10^8cells/mL$. The use of LF slag was effective for the removal of phosphate and the removal efficiency of phosphate was greater than 80% for up to 100 bed volumes.

Effects of ion-exchange for NOM removal in water treatment with ceramic membranes ultrafiltration

  • Kabsch-Korbutowicz, Malgorzata;Urbanowska, Agnieszka
    • Membrane and Water Treatment
    • /
    • 제3권4호
    • /
    • pp.211-219
    • /
    • 2012
  • To enhance the efficiency of water treatment and reduce the extent of membrane fouling, the membrane separation process is frequently preceded by other physico-chemical processes. One of them might be ion exchange. The aim of this work was to compare the efficiency of natural organic matter removal achieved with various anion-exchange resins, and to verify their potential use in water treatment prior to the ultrafiltration process involving a ceramic membrane. The use of ion exchange prior to ceramic membrane ultrafiltration enhanced final water quality. The most effective was MIEX, which removed significant amounts of the VHA, SHA and CHA fractions. Separation of uncharged fractions was poor with all the resins examined. Water pretreatment involving an ion-exchange resin failed to reduce membrane fouling, which was higher than that observed in unpretreated water. This finding is to be attributed to the uncharged NOM fractions and small resin particles that persisted in the water.

Vermicomposting 에 의한 유기성 폐기물의 처리 (Treatment of Organic Waste by Vermicomposting)

  • 조익환;이주삼;전하준
    • 한국유기농업학회지
    • /
    • 제5권1호
    • /
    • pp.125-135
    • /
    • 1996
  • A study was made to investigate the possibility of treating various organic waste of cattle manure, swine manure, goat manure, apple pomace, chinese medicine residue and coffee less by feeding these to earthworms and then by studying the growth and reproductive efficiency of earthworms, and the chemical composition of worm cast and its production. The results are summarized as follows. 1. When the feed for earthworms were in good condition which were cattle manure, swine manure and apple pomace, the reproductive efficiency of earthworms was improved however in worse condition the feed of which were goat manure and chinese medicine residue, the increasing rate(IR) became faster. 2. Despite the high content of organic matter(OM) in coffee lees, the earthworms fed coffee lees showed significantly lower reproductive efficiency and increasing rate(IR) than those fed other organic waste due mainly to its lower pH and lower total nitrogen(TN) content. Therefore, when coffee lees is considered to be fed to earthworms, it is believed necessary to be mixed with addiveves or other organic waste in order to improve the feed condition. 3. pH in swine manure, goat manure, apple pomace, chinese medicine residue and coffee lees became neutralized by being fed by earthworms. 4. Available P2O5 and exchangeable cation(EC) of earthworm cast were a little increased compared to those of feed. The contents of Mn, Fe and Cu in earthworm cast were a little decreased to compared to those of feed. 5. The contents of Mn, Fe and Cu in earthworm cast were a little a decreased to compared to those of feed. 6. Mean fresh weight of earthworm at final time(FW2) was negatively correlated with number of young worms(NY)(P<0.01), but positively with increasing rate(IR) (P<0.001) and C/N ratio(P<0.05) respectively. Number of cocoons (NC) and fresh weight of cocoons(WC) were positively(P<0.01) correlated with fresh weight of young worms (WY) and digested matter(DI) but negatively(P<0.001) correlated with residual matter(WY) and digested matter(DI) but negatively(P<0.001) correlated with residual matter(RW). Number of young worms(NY) and fresh weigh of young worms(WY) were negatively(P<0.001) correlated with increasing rate(IR), however increasing rate(IR) of earthworm was positively(P<0.05) correlatedd with C/N ratio.

  • PDF

용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구 (Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.