A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

유리선량계를 이용한 투과선량 기반 환자선량 평가 시스템 개발을 위한 가능성 연구 (Feasibility Study for Development of Transit Dosimetry Based Patient Dose Verification System Using the Glass Dosimeter)

  • 정성훈;윤명근;김동욱;정원규;정미주;최상현
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.241-249
    • /
    • 2015
  • 방사선치료는 수술, 항암치료와 함께 암의 3대 치료방법으로써 많은 암환자들이 방사선치료를 받게 된다. 최대한 많은 방사선을 암에 집중시키고 최대한 적은 방사선을 주변 정상 조직에 가해주기 위해 치료 전 치료계획을 철저히 세우고 품질 관리를 시행하지만 방사선치료가 잘못 시행되어 의도치 않은 방사선이 환자에게 전달되는 의료사고가 발생하기도 한다. 이를 해결하기 위해 환자 내부의 선량을 검증하기 위한 방법을 투과선량 측정을 통한 환자 내부선량의 역추정 방법이 제시되고 있다. 본 연구에서 제시한 투과선량을 이용한 환자선량 계산 방법을 거리역자승법칙, 심부선량백분율, scatter factor를 이용한 방법으로써 실제 환자 선량 평가 가능성에 대해 균질한 물등가 팬텀을 이용한 연구이다. 투과선량에 대한 이온함과 유리선량계의 교정 결과 유리선량계의 신호값이 이온함으로 측정한 선량값에 비해 6 MV에서 0.824, 10 MV에서 0.736배인 것으로 나타났고 scatter factor는 평균적으로 1.4정도인 것으로 확인되었다. 심부선량백분율 데이터를 사용하기 위해 Mayneord F factor를 적용하였으며 위의 정보들을 이용하여 균질한 팬텀에서 알고리즘을 검증한 결과 최대 오차 약 1.65%로 계산이 정확하게 실시됨을 확인하였다.

6 MV 광자선의 투과성필터와 Wedge 선속을 이용한 부비강의 균등선량계획 (Homogeneous Dose Planning to Paranasal Sinus with the Partial Attenuation filters and Wedged Beams in 6 MV Photon Beam)

  • 최태진;이호준;김옥배
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.183-191
    • /
    • 1993
  • The homogeneous dose planning is one of the most important roles in radiation therapy. But, it is not easy to obtain a homogeneous dose to paranasal sinus region including the ethmoidal sinus with conventional irradiation techniques. In this experimental study, the authors tried to get a homogeneous dose at PNS region, but the nasal cartirage does not exceed the tolerance dose, with anterior-posterior beam and two both lateral wedged beams. Used three fields were shielded with full thickness of blocks to preserve the eye-balls and with blocks of one half value layer to create a homogeneous dose at the whole treatment volume. The dose computations are based on the three dimensonal structure with modified scatter contributions of partial shielders and attenuated beams in 6 MV photon beams. The dose distributions of mid-plane is examined with Kodak verification films and teflon-embedded TLD rod (1 mm diameter and 6 mm length) to confirm the computed dose. In our study, the whole PNS regions have shown within $85{\%}$ of the resultant isodose curves with relatively homogeneous dose distribution. The results of dose computation and measurements are agree well within $5{\%}$ uncertainties.

  • PDF

세기변조 방사선치료의 환자 치료 전 선량보증에 대한 고찰 (Review on the Pre-treatment Quality Assurance for Intensity Modulated Radiation Therapy)

  • 한영이
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.213-219
    • /
    • 2013
  • 본 논문은 현재 세기변조 방사선 치료를 시행 시에 일반적으로 사용 되고 있는 환자 치료 전 품질보증의 방법 중, 2차원 선량분포를 측정하여 품질을 보증하는 방법들에 관한 이슈들을 최근 3~4년 간 발표된 논문들을 중심으로 살펴보고, 향후 품질보증 방법의 개선방향에 대하여 조명해 보고자 하였다.

두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰 (The usefulness of Forward IMRT for Head and Neck Cancer)

  • 백금문;김대섭;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제15권1호
    • /
    • pp.41-52
    • /
    • 2003
  • I. 목적 방사선 치료계획에 있어서 정상조직의 선량과 치료부위 선량의 분포는 매우 중요하다. 또한 치료부위의 균일한 선량분포를 얻기 위하여 여러 가지 방법을 이용하고 있다. 특히 두경부(Head & Neck) 종양의 방사선 치료 시 체표 윤곽의 변화가 심하여 이에 따른 선량 불균일 보정이 필요하다. 기존의 치료방법으로는 parotid gland 와 spinal cord 의 tolerance dose 이하를 유지하면서 planning target volume(PTV)에 충분한 치료 선량을 전달하기에는 여러 가지 어려움이 있다. 이에 본원에서는 Forward IMRT를 이용한 방사선 치료의 유용성 및 실용적인 정도관리 방법에 관한 연구를 하였다. II. 대상 및 방법 본 연구는 두경부(Head & Neck) 종양 비인두암(nasophrygeal cancer)의 방사선 치료가 요구되는 환자를 대상으로 하여 2차원적인 치료계획과 dynamic Mulit-Leaf Collimator(dMLC)를 이용하여 partial block technique(PBT)방법을 적용한 Forward IMRT를 위한 치료계획을 dose volume histogram(DVH)로 비교 분석하였다. 또한 정도관리(quality assurance, QA)를 위하여 필름과 pinpoint chamber를 이용하여 정확한 선량 평가를 실시하였다. III. 결과 2차원적인 치료계획과 Forward IMRT를 적용한 치료계획의 DVH를 비교 분석한 결과 Forward IMRT를 적용한 치료계획이 Rt, Lt parotid gland와 spinal cord에 들어가는 선량을 좀더 줄일 수 있었다. 이러한 Forward IMRT의 시도로 조사면의 방사선 세기가 정상조직의 보호를 개선시키고 치료의 최적화를 이룰 수 있었다. Inverse IMRT에 비해 기존의 3차원적 치료계획 장치를 이용할 수 있고 비교적 단순한 방사선 세기 패턴이므로 정도관리가 용이하였다. IV. 결론 Forward IMRT는 2차원적인 치료법에 비하여 PTV에는 균일한 선량분포를 이루면서 정상조직에는 tolerance dose 이하로 선량을 전달 할 수 있는 치료기법이었다.

  • PDF

Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF

Conventional, IMRT, VMAT을 이용한 CSI 치료시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통한 치료계획 비교 (Comparison treatment planning with the measured change the dose of each Junction section according to the error of setup CSI Treatment with Conventional, IMRT, VMAT)

  • 이호진;전창우;안범석;유숙현;박소연
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.217-224
    • /
    • 2014
  • 목 적 : Conventional, IMRT, VMAT을 이용한 CSI치료 시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통해 치료계획을 비교한다. 대상 및 방법 : 본원에서 CSI 치료환자를 대상으로 이클립스 10.0(Eclipse10.0, Varian, USA)를 이용하여 Conventional, IMRT, VMAT 치료계획을 세웠다. 또한 필름측정을 위하여 각 치료계획마다 IMRT QA phantom을 적용한 Verification plan을 생성하였다. 이때, 각 치료기법의 Setup 오차는 0, 머리방향으로 2, 4, 6mm, 다리방향으로 2, 4, 6mm로 적용하였다.(이하, '+'는 머리 방향, '-'는 다리방향을 의미한다.) IMRT QA Phantom과 EBT2 film을 이용하여, 각 치료기법별로 Junction부의 Setup 오차를 0, +2, +4, +6, -2, -4, -6mm로 이동하여 조사하였다. Film을 Scan하여 감마지수(Gamma index,${\gamma}$)를 도출하여, 측정된 Film과 치료계획상의 선량분포와의 일치성을 확인한 후, Setup 오차에 따른 Conventional, IMRT, VMAT 치료계획별 선량분포도를 비교하였고, Homogeneity Index(HI)를 계산하여 표적 내 선량분포의 균일성을 분석하였다. 결 과 : Film으로 측정하여 얻은 감마지수는 90.49%로 Film scan값과 치료계획상의 선량분포와의 일치성을 확인하였다. 또한, 거리에 따른 선량분포도에 따르면, Setup 오차를 머리 방향으로 2, 4, 6mm설정하면 Conventional의 $^*Diff$(%)는 3.1, 4.5, 8.1, IMRT는 1.1, 3.5, 6.3, VMAT은 1.6, 2.5, 5.7으로 나타났다. 같은 방법으로 Setup 오차를 다리방향으로 2, 4, 6mm로 설정을 하면 Conventional의 $^*Diff$(%)는 -1.6, -2.8, -4.4, IMRT는 -0.9, -1.6, -2.9, VMAT은 -0.5, -2.2, -2.5으로 나타났다. Homogeneity Index(HI)는 Conventional 1.216, IMRT 1.095, VMAT 1.069로 값을 얻었다. 결 론 : Dose homogeneity와 Junction 부위에 대한 완만한 Dose gradient의 장점을 가진 IMRT와 VMAT을 이용한 CSI치료는 Conventional 기법보다 Setup 오차에 따른 Junction 부위의 선량의 변화가 적었고, 균일성 또한 좋게 나타났다. 이러한 적은 선량의 변화는 CSI치료 시 발생하는 Setup 오차에도 환자에게 위험성이 적음을 의미한다.

Chest-wall Surface Dose During Post-mastectomy Radiation Therapy, with and without Nonmagnetic Bolus: A Phantom Study

  • Choi, Cheon Woong;Hong, Joo Wan;Park, Cheol Soo;Ahn, Jae Ouk
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.293-297
    • /
    • 2016
  • For mastectomy patients, sufficient doses of radiation should be delivered to the surface of the chest wall to prevent recurrence. A bolus is used to increase the surface dose on the chest wall, whereby the surface dose is confirmed with the use of a virtual bolus during the computerized treatment-planning process. The purpose of this study is an examination of the difference between the dose of the computerized treatment plan and the dose that is measured on the bolus. Part of the left breast of an Anderson Rando phantom was removed, followed by the attainment of computed tomography (CT) images that were used as the basis for computerized treatment plans that were established with no bolus, a 3 mm-thick bolus, a 5 mm-thick bolus, and a 10 mm-thick bolus. For the computerized treatment plan, a prescribed dose regimen was dispensed daily and planning target volume (PTV) coverage was applied according to the RTOG 1304 guidelines. Using each of the established computerized treatment plans, chest-wall doses of 5 points were measured; this chest-wall dose was used as the standard for the analysis of this study, while the level of significance was set at P < 0.05. The measurement of the chest-wall dose with no bolus is 1.6 % to 10.3 % higher, and the differences of the minimum average and the maximum average of the five measurement points are -13.8 and -1.9, respectively (P < 0.05); however, when the bolus was used, the dosage was measured as 3.7 % to 9.2 % lower, and the differences of the minimum average and the maximum average are 7.4 and 9.0, -1.2 and 17.4, and 8.1 and 19.8 for 3 mm, 5 mm, and 10 mm, respectively (P < 0.05). As the thickness of the bolus is increased, the differences of the average surface dose are further increased. There are a variety of factors that affect the surface dose on the chest wall during post-mastectomy radiation therapy, for which verification is required; in particular, a consideration of the appropriate thickness and the number of uses when a bolus is used, and which has the greatest effect on the surface dose on the chest wall, is considered necessary.

Ir-192 선 선원의 선량분포에 관한 품질보증 (Quality Assurance on Dose Distribution of Ir-192 Line Source)

  • 김종언
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권1호
    • /
    • pp.33-38
    • /
    • 2007
  • 이 연구는 플라토 치료계획시스템의 치료계획에서 Ir-192 선원에 대한 처방점의 처방선량과 선원 주위의 선량분포상의 선량점들의 선량이 정확하게 계산되는지를 확인하는데 그 목적이 있다. 선원의 중심축의 전후방향에서의 평면의 직교좌표계와 측면방향에서의 평면의 직교좌표계 및 선원을 A4 용지 위에 그려서 치료계획시스템에 입력하였다. 처방선량은 선원중심으로부터 극각 $90^{\circ}, $270^{\circ}의 방향으로 반경 1 cm인 두 지점에 400 cGy를 처방하였다. 처방점과 선량점들의 선량은 치료계획시스템에서 출력된 선량과 파울 킹 등이 유도한 기하학 함수식으로 계산된 선량을 분석하였다. 본 실험의 분석에서 처방 점의 선량은 오차 없이 정확하게 일치하였고, 선량 점들의 선량은 1.85% 이내의 오차를 얻었다. 그리고 플라토 치료계획시스템의 선량계산은 허용오차 ${\pm}2%$ 범위 이내의 정확성으로 분석되었다. 파울 킹 등이 유도한 기하학 함수식을 사용하여 손으로 계산한 선량은 높은 정확성의 품질보증과 편리성에 기인하여, 임상에서 사용하는데 유용할 것으로 생각된다.

  • PDF

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.