• Title/Summary/Keyword: Treatment basins

Search Result 43, Processing Time 0.023 seconds

A Study on Flow Distribution to Flocculation Basins Using DOE and RSA (실험계획법과 반응표면분석법을 적용한 응집지로의 유량분배에 관한 연구)

  • Kim, Seong-Jae;Kyung, Gyu-Sun;Jeong, Heui-Jung;Kim, Hyeong-Seop;Yang, Sa-Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.918-928
    • /
    • 2013
  • The inequitable flow distribution to flocculation basins is an important problem faced in many water treatment plants. This is caused by the structure of a distribution channel, the height differences of outlet weirs etc. But, a modified approach for the structures has no effectiveness to achieve flow equality. The aim of this study is to reduce the inequality by adopting optimized inlet valve opening (%) of the flocculation basins using DOE (Design of Experiments) and RSA (Response Surface Analysis). The inlet valve openings (%) and inflow distributions (%) of 6 paralleled basins were set as factors (X) and characteristics(Y) respectively. 2 level factorial experiments and RSA were conducted for optimization and regression analysis (Y = f(X) + Const.). Adopting the optimized inlet valve opening (%) at field, standard deviation of flow distribution (%) and effluent turbidity was declined from 3.80% to 0.42% and from 0.29 NTU to 0.03 NTU respectively.

A study on the characteristics of wastewater flowrate in land-use of Sogwipo-city in Cheju (제주도 서귀포시지역의 용도지역별 하수발생량 특성에 관한 연구)

  • Jeong, Gwang Ok;Ryu, Seong Pil
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.251-262
    • /
    • 2004
  • To identify the characteristics of wastewater flow generated in treatment basins of Seogwipo-city, we selected 3 stations representing the basin and performed 7 times of field survey including 5 times in dry periods and 2 times in wet periods from Feb. 25 to May 27, 2002 for the selected stations. From the analysis of flow data measured for more than 60 days in the interval of 5 minutes and concentration data obtained from laboratory analysis, we can draw several conclusions. First, in the analysis of diurnal variation of wastewater flow for land-use types, we could find the following results: in the residential area, it is observed that wastewater flow rates rise early in the morning for the office-going hour and fall gradually and rise again after the office-leaving hour, showing typical residential wastewater flow pattern, while for the residential and commercial area flow rates rise early in the morning at the office-going hour and move up and down repeatedly within wide range and last till the office-leaving hour, which can be resulted from wastewater that is generated by tourists activated after early in the afternoon, while for the touristy area flow rates rise early in the morning and fall gradually and rise again within wide range. Second, in the analysis of temporal variation of wastewater flow for monthly, it can be observed that in the residential area, in the residential and commercial areas the flow rate of May is higher than that of Feb., March, while for the touristy area flow rate is without monthly because it reflects the movement of population, Third, in wet periods concentration of water-quality item such as SS, BOD, and COD_{cr}$ is high in the beginning of rainfall by first flush, and falls down gradually to reach the steady state, which is the level of wastewater in dry periods after the cease of storm water due to diluting effect resulting from additional runoff water through storm sewers.

Comparison of infiltation rate for separate sewer system and combined sewer system in sewer maintenance areas (하수관로정비 지역의 분류식과 합류식 하수관로의 침입율 비교)

  • Gu, Gwangmo;Chu, Shaoxiong;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.191-200
    • /
    • 2020
  • This study is to improve the efficiency of BTL (Build Transfer Lease) project operation by comparing the infiltration rate based on the data of 5 years of infiltration of the separate sewer system and combined sewer system. In the survey site, the separate sewer system area consists of eight flowmeters in seven treatment basins, and the combined sewer system area consists of eight flowmeters in five treatment basins. The infillration rate was analyzed by night-time domestic flow evaluation method, and the average infiltration rates of the separate sewer system and combined sewer system were 13% and 16%, respectively. Combined sewer system was about 1.3 times higher than the separate sewer system. The average BOD of separate sewer system was 233 mg/L, which was about 2.4 times higher than the combined sewer system was 107 mg/L. In the comparison of the average pipe diameter-length infiltration of separate sewer system and combined sewer system, the separate sewer system and the combined sewer system were about 0.150 ㎥/d/mm/km and about 0.109 ㎥/d/mm/km, respectively. The floating population in mixed residential and commercial areas has been identified as the cause. Therefore, we propose a method to calculate the infiltration rate in consideration of the margin ratio in the area where the night active population is concentrated.

Spatial distribution of wastewater treatment plants in diverse river basins over the contiguous United States

  • Soohyun Yang;Olaf Buettner;Yuqi Liu;Dietrich Borchardt
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.142-142
    • /
    • 2023
  • Humans inevitably and continuously produce wastewater in daily life worldwide. To decrease the degradation of river water bodies and aquatic ecosystem therein, humans have built systems at different scales to collect, drain, and treat household-produced wastewater. Particularly, municipal wastewater treatment plants (WWTPs) with centralized controls have played a key role in reducing loads of nutrients in domestic wastewater for the last few decades. Notwithstanding such contributions, impaired rivers regarding water quality and habitat integrity still exist at the whole river basin scale. It is highly attributable to the absence of dilution capacity of receiving streams and/or the accumulation of the pollutant loads along flow paths. To improve the perspective for individual WWTPs assessment, the first crucial step is to achieve systematic understanding on spatial distribution characteristics of all WWTPs together in a given river basin. By taking the initiative, our former study showed spatial hierarchical distributions of WWTPs in three large urbanized river basins in Germany. In this study, we uncover how municipal WWTPs in the contiguous United States are distributed along river networks in a give river basin. The extended spatial scope allows to deal with wide ranges in geomorphological attributes, hydro-climatic conditions, and socio-economic status. Furthermore, we identify the relation of the findings with multiple factors related to human activities, such as the spatial distribution of human settlements, the degree of economy development, and the fraction of communities served by WWTPs. Generalizable patterns found in this study are expected to contribute to establishing viable management plans for recent water-environmental challenges caused by WWTP-discharges to river water bodies.

  • PDF

Development of Constructed Wetlands Design Model for Water Quality Management in Rural Basins (농촌유역의 수질관리를 위한 인공습지 설계모형 개발)

  • Choi, In-Uk;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.497-500
    • /
    • 2001
  • Constructed wetlands are among the recently proven efficient technologies for wastewater treatment. Compared to conventional treatment systems, constructed wetlands are low cost, are easily operated and maintained. Constructed wetlands are particularly sensitive to Nonp oint source pollution(NPSP) because they function as pollutant sinks. The objectives of this study were to review the necessary contents of survey and design factors for constructing constructed wetlands and develop a modified DSS-WQMRA model for design of constructed wetlands. From the results of the case studies, in order to attain BOD target water quality, 0.27%(SF), 0.66%(FWS) wetland area of the total basin is needed.

  • PDF

Experiences of Optimization of Flocculation Basins in Water Treatment Plants (정수장 응집공정의 최적운전조건 결정 사례)

  • Han, Moo-Young;Chung, Young-Kyun;Park, Yong-Hyo;Kim, Jeong-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.311-317
    • /
    • 2000
  • The operation of flocculation process and the evaluation thereof have been mainly based on G, t and $G{\times}t$ values which are available from design guidelines and texts. However, their suggested ranges are too wide to find the optimum condition specific to a particular water treatment plant and none of the existing method can be used to evaluate and suggest the optimum operational condition. Recently, a commercially available particle counter is found to be useful in determining the flocculation process based on the particle dynamics. The optimum condition is defined as one that best suits the purpose of flocculation; the number of small particles should decrease, while that of large particles should increase. The experiments were performed at two conventional water treatment plants in Korea, one with horizontal mechanical flocculators, and another with vertical type mechanical flocculators. In this paper, experiences to evaluate the flocculation process and to suggest the optimum operation condition will be presented. Although particle counting method is found to be beneficial compared to any other existing methods, the optimum condition is very much site-specific and should be evaluated at each water treatment plant for different conditions.

  • PDF

Design of Closed Seawater Recirculating Aquaculture System for Korean Rockfish Sebastes schlegeli Culture

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • v.26 no.1
    • /
    • pp.102-111
    • /
    • 2004
  • Recirculating aquaculture system (RAS) consists of different treatment compartments that maintain water quality within the ranges commonly recommended for fish cultures. However, common RASs still exert considerable environmental impact since concentrations of organic matter and nutrients in their effluents are high. Compared with the traditional RAS, the model RAS developed here use a sedimentation basin for digestion purposes and then use the released volatile organic matter to stimulate a denitrification process. Different treatment compartments for solids, total ammonia nitrogen, and nitrate removal have been reviewed. This paper provides the basic information on designing different treatment compartments as well as the engineering criteria in closed seawater RAS, consisting of circular tanks for fish cultures; dual drain systems, sedimentation basins and foam fractionators for removal of solids; nitrification biofilters for TAN removal; denitrification biofilters for nitrate removal; and aerators for aeration. The main purpose is to outline a common procedure in designing of closed RAS for marine fish culture with an emphasis on easy management and low expense, as well as reduction of the environmental impact.

Integrated Watershed Modeling Under Uncertainty (불확실성을 고려한 통합유역모델링)

  • Ham, Jong-Hwa;Yoon, Chun-Gyoung;Loucks, Daniel P.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.4
    • /
    • pp.13-22
    • /
    • 2007
  • The uncertainty in water quality model predictions is inevitably high due to natural stochasticity, model uncertainty, and parameter uncertainty. An integrated modeling system under uncertainty was described and demonstrated for use in watershed management and receiving-water quality prediction. A watershed model (HSPF), a receiving water quality model (WASP), and a wetland model (NPS-WET) were incorporated into an integrated modeling system (modified-BASINS) and applied to the Hwaseong Reservoir watershed. Reservoir water quality was predicted using the calibrated integrated modeling system, and the deterministic integrated modeling output was useful for estimating mean water quality given future watershed conditions and assessing the spatial distribution of pollutant loads. A Monte Carlo simulation was used to investigate the effect of various uncertainties on output prediction. Without pollution control measures in the watershed, the concentrations of total nitrogen (T-N) and total phosphorous (T-P) in the Hwaseong Reservoir, considering uncertainty, would be less than about 4.8 and 0.26 mg 4.8 and 0.26 mg $L^{-1}$, respectively, with 95% confidence. The effects of two watershed management practices, a wastewater treatment plant (WWTP) and a constructed wetland (WETLAND), were evaluated. The combined scenario (WWTP + WETLAND) was the most effective at improving reservoir water quality, bringing concentrations of T-N and T-P in the Hwaseong Reservoir to less than 3.54 and 0.15 mg ${L^{-1}$, 26.7 and 42.9% improvements, respectively, with 95% confidence. Overall, the Monte Carlo simulation in the integrated modeling system was practical for estimating uncertainty and reliable in water quality prediction. The approach described here may allow decisions to be made based on probability and level of risk, and its application is recommended.

Evaluation of Hydrodynamic Behavior in Horizontal Settling Basin with Archimedes number (Archimedes number를 이용한 장방형 침전지내 수리흐름 평가에 관한 연구)

  • Park, No-Suk;Lee, Sanguk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.865-870
    • /
    • 2009
  • In this study, the adequacy of Reynolds numbers and Froude numbers derived from about sixty domestic water treatment plants (WTPs) were analyzed in order to estimate the characteristics of hydraulic behavior within the rectangular shaped sedimentation basins used widely. From the results of analysis, most of domestic WTPs have satisfied the criteria regulated as that Reynolds number should less than 1,000(dimensionless). On the other hand, they have not been able to satisfy the Froude number criteria, which should be higher than $1.0{\times}10^{-6}$. The reasons why most of domestic WTPs could not satisfy the criteria are that its criteria basis has been not only inadequate, but also the concept of external flow occurred around a settling particle has been ignored. Accordingly, this study proved the feasibility of Archimedes number, which indicates the ratio between particle Reynolds number and Froude number, to evaluate the hydraulic efficiency and its function of scale factor.

Examining the Equality of Multi-Outlet Flow Rates within a Dual Open Channel (이중 수로 구조의 분배수로 내 다지점 유출 유량의 균등성 평가에 관한 연구)

  • Kim, Seong-Su;Park, No-Suk;Jeong, Woo-Chang;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.423-430
    • /
    • 2012
  • This study was conducted to qualify the equality of the flow distribution from open channel between rapid mixing basin and flocculation basins in a domestic S_ water treatment plant, and to suggest a remedy for improving the equality. In order to evaluate the feasibility of the suggested remedy, computational fluid dynamics (CFD) technique are used, and for verifying the CFD simulation results tracer tests were carried out. From the results of CFD simulation and tracer tests, it was investigated that the modification of hydraulic structure in the distribution channel, which is to install the longitudinal orifice baffle in flow direction, could improve the equality of the flow distribution over 75%.