Survey of Traditional Korean Medical Device : Number of devices, Problems, Solution Plan (한방 의료기관의 의료기기 보유현황 및 한방의료기기의 문제점과 개선방안에 대한 조사 연구)

  • Kim, Ji Hye;Kim, Jaeuk U.;Kim, Keun Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.430-439
    • /
    • 2014
  • This study was performed to assess the perception and needs of the traditional Korean Medical Equipment (KME) in clinic. We conducted survey research among 15,550 traditional Korean medical doctors (KMD) responded to e-mail during 2 weeks. 899 participants the survey, consisting of questions regarding 'number of devices of the KME' and 'solution and improvement plan of the KME'. The participants were asked to choose their ranking of problems of the KME and also put a check mark in the column that the reasons for this choice. As results, final scores in priority ranking medical devices were derived in 7 categories. Physical therapy equipment and acupuncture treatment devices were included in high ranks. 42.8 % of the participants responded that the diagnostic medical devices seemed important in clinics and 67.4 % of the participants indicated that the therapeutic medical devices seemed to important in clinics. The identified problems of KME were 'low reproducibility and reliability of a diagnosis result (24.8%)' and 'uncertain validity of a diagnostic medical devices (20.5%)'. The improvement plan of the problems were 'to establish the law for using the medical devices (26.6%)' and 'evaluation of validity of the KME (26.2%)'. A survey of KMD revealed the condition of KME's number of devices and the solution plan for the problem of several KMEs. Understanding the needs of KMD could probably contribute to the research and development of KMEs in the future.

A study on the traceability and uncertainty of skin hydration measurement on the sole of the foot

  • Yang, Gi-Young;Choi, Ji-Won;Chae, Han;Lee, Byung-Ryul
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.55-61
    • /
    • 2017
  • Objectives: In order to accurately measure skin moisture and accumulate normal skin moisture data, analyzing the uncertainty of the skin moisture measurement and establishing standard reference data is essential. It helps to evaluate the skin's condition and has great significance in diagnosis and treatment. In this study, the traceability of the equipment and the uncertainty of the results were analyzed for their potential use in the field of Korean medicine. The data was collected measuring skin moisture on the sole of the foot. Methods: One professional measured the moisture of the adult male's foot 10 times following a determined protocol. The standard uncertainty of repeated measurements was calculated from the mean value of 10 repeated measurements. Ten trainee participants also measured the adult male's foot following a determined protocol. The standard uncertainty by tester was calculated from the value of repeated measurements. Results: As a result of analyzing the difference between the mean and standard uncertainties in both the expert and trainees, it was confirmed that the variance in this study did not satisfy the normal distribution. In addition, the Mann-Whitney U-test was carried out, and it was found that there was no significant difference in the measured values of the two groups. The authorized uncertainty of measurements and traceability of all the equipment was not confirmed. Conclusions: This paper establishes the basis for later measurement-equipment research to provide the objective indicators to approach the dryness of plantar skin from dehydration, the Korean medicine perspective.

A Study on Quality Improvement of Medical Equipments (의료기기 QI 활동 개선방안에 대한 연구)

  • Kang, Hun-Hee;Juh, Ra-Hyeong;Kim, Jong-Soon;Kim, Seo-Hwak;Huh, Soo-Jin
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.190-201
    • /
    • 1998
  • Background : Medical equipments take a very important role in diagnosis and treatment of disease in modern medicine and effective maintenance of the equipments is a necessary to provide a good health care to the public. After developing a new QC program for effective maintenance of medical equipments and practicing it for a year, we report the results of the new program. Methods : The maintenance data of 9 equipments in 8 categories including a CT Scanner were analyzed with regard to the parts responsible for most frequent failure and cause of the failure. After learning the most frequent failure part and cause of the failure, we developed a new QC program that emphasizes preventive maintenance of the most frequent failure part. We compared the number of failure per year and active rate of each equipment before and after the adoption of the new QC program. Results : The average number of failure per year per equipment was 20.7 before and it decreased by 43% to 11.9 after adoption of the new QC program. The average active rate of the equipments was 92.6% before and it increased by 3.2% to 95.8% after adoption of the new program. Conclusions : The practice of the new QC program appears very useful as it decreased the failure rate and increased the active rate of the equipments.

  • PDF

The implementation of liquefaction equipment monitoring system based on Android (안드로이드 기반의 유증기 액화장치 모니터링 시스템 구현)

  • Park, Man-Kyu;Tack, Han-Ho;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.583-589
    • /
    • 2016
  • Volatile organic compounds(VOCs) are regarded as a harmful cause substance not only causing air pollutions but also causing global warming phenomenon. For this reason, VOCs are managed politically to reduce emissions by each country. In particular, the vapor from the gas station contains VOCs which is harmful to the human body such as carcinogens benzene and pollute the atmosphere, the Ministry of Environment defined every gas station must install vapor recovery equipment to recover volatile organic compounds. Recently, there are many accidents caused by existing vapor treatment methods, the liquefaction recovery technology is getting the spotlight to cool the vapor at the field. However, because the liquefaction recovery technology have risks of fire or explosion in accordance with temperature, the real time monitoring is critical factor. In this paper, we implement an Android-based monitoring application for liquified vapor recovery device which attached sensor module for temperature and power to monitoring real time information.

Development of equipment for tumor cauterization

  • Hoshino, Hirokazu;Ochiai, Makoto;Sakasegawa, Aya;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.474-477
    • /
    • 2002
  • Equipment to cauterize tumors by an electrically heated Kanthal wire is under development. The wire( alloy of iron, chromium and Aluminum) keeps sufficient strength up to 1400 degrees in Celsius. Although AC 50Hz current source is used in the prototype experiment, RF current will be used in future. The diameter of the Kanthal wire was 0.3 mm which was connected to Kanthal wire of 0.8 mm. The thicker wire was used as a leading wire. The possibility of application of the heating wire in combination with an ultrasound endoscope was determined, where ultrasound endoscope is to be used to monitor the location on the wire and an extent of a tumor in digestive organs. This procedure requires the wire to be applied inside ultrasound transmitting media. First, the wire was applied in the degassed water in which a chicken liver sample was submerged. The wire, however, burned out in water soon after it became red-hot at 12 A. The reason is that large current is required for the wire to become red-hot due to strong convection. Starch paste of 3 weight percent was employed instead of water. This made the wire red-hot approximately at 6 A, showing the increased viscosity of the starch decreased the convection and the wire was cover by the steam. The liver sample was cauterized successively, while the location of the wire and the liver was monitored by an ultrasound diagnosis equipment outside the plastic vessel of the starch paste.

  • PDF

Verification of Periodical Calibration for Iso-center Positions using Quality Assurance System for Irradiation Equipment Position Established at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.192-194
    • /
    • 2002
  • We present the results on the calibration of iso-center positions using the quality assurance system established at PMRC for determination of center position in X-ray and proton irradiation fields. Details on the system are presented in another presentation in this session. The equipment in the system is mounted on a patient treatment bed in each proton exposure room, G1 or G2. A center of a stainless ball on the equipment is set at a cross of laser markers located around the iso-center and fixed on the room and on the snout in the gantry. A proton beam or an X-ray beam is exposed onto the ball through a brass collimator of 100 mm ${\times}$ 100 mm and projected onto the imaging plate set at I cm behind the ball. On the axis perpendicular to the thrust axis of the gantry on the imaging plate, a distance between a center of the collimator image and a center of the ball image varies as a cosine function of gantry angles unless the ball is set on the iso-center. An amplitude of the cosine curve shows the distance between the ball and the iso-center, an offset the offset of the collimator, and a phase shift at a zero crossing point the ball direction viewed from the iso-center. We present the relation among the iso-center position, the laser maker position, and the center of proton and X-ray irradiation fields. Its stability and its reproducibility are discussed.

  • PDF

Development of High Erosion Resistant Fe-based Alloy for Continuous Hot Dipping Line (연속용융 도금라인 용 고내침식 Fe계 합금 개발)

  • Baek, Min-Sook;Kim, Yong-Cheol;Baek, Kyeong-Cheol;Kwak, Joon-Seop;Yoon, Dong-Joo
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.3
    • /
    • pp.95-103
    • /
    • 2020
  • In this study, the material used in the hot dip galvanizing equipment was poorly corrosion-resistant, so it was performed to solve the cost and time problems caused by equipment replacement. The theoretical calculation was performed using the DV-Xα method(Discrete Variational Local-density approximation method). The alloy (STS4XX series) of the equipment currently used has a martensite phase. Therefore, the theoretical calculation was performed by applying P4 / mmm, which is a tetragonal structure. The new alloy was chosen by designing theoretical values close to existing materials. Considering elements that contribute to corrosion, most have high prices. Therefore, the design was completed by adjusting the content using only the components of the reference material in the theoretical design. The final design alloys were chosen as D6 and D9. Designed D6 and D9 were dissolved and prepared using an induction furnace. After the heat treatment process was completed, the corrosion rate of the alloys was confirmed by using the potentiodynamic polarization test. The surface of the prepared alloys were processed horizontally and then polished to # 1200 using sand paper to perform potentiodynamic polarization test. Domestic products: 4.735 mpy (mils / year), D6: 0.9166 mpy, D9: 0.3372 mpy, alloys designed than domestic products had a lower corrosion rate. Therefore, the designed alloy was expected to have better erosion resistance.

Development of LED Irradiation System for Cell Proliferation (세포증식을 위한 LED 조사 시스템 개발)

  • Cheon, Min-Woo;Park, Yong-Pil;Lee, Ho-Shik;Kim, Tae-Gon;Kim, Young-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.581-582
    • /
    • 2010
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage.

  • PDF

The Current Status and Recommendation of Work Environment Management in Small Scale Industry with less than 5 Workers (경인지역 일부 5인미만 사업장 근로자의 작업환경실태와 관리대책)

  • Kim, Dea Sic;Roh, Youngman;Kim, Hyun Wook;Jeong, Chun Hwa;You, Ki ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • This study was performed to identify the current status of work environment management and to provide appropriate recommendations for small scale industry with less than 5 workers from September, 2000 to October, 2000 in Seoul city and Gyoung-gi province. The 211 companies were surveyed by checklist included the elements of management of work environment, hazardous chemicals, MSDS, personal protective equipment, and ventilation system. The proportion of metal products manufacturing and printing industries are 25.6 % and 22.3%, respectively. The daily working hours in printing industry is longer than others. The industries that produce potentially hazardous agents, such as noise, dust, metal, organic solvents, radiation and chemical material are pulp, plating, machinery, and printing, respectively. In above industries, only 2.8 % of those recognised and had MSDS. The proportion of companies providing fire extinguishers, safety showers are found to be 13.3 %, 7.1 %, respectively. Only 24.2 % of companies provided personal protective equipment to the workers. The ventilation system was operated in most of companies. But local exhaust ventilation system is provided to 22.3 % of those, also had not been annually inspected. This study showed that the current status of occupational safety and health was not appropriate for workers in small scale industries. It is suggested that annual physical examination have to be performed, MSDS usage must become widespread, and employer and emplyees in small scale industry should be educated for the treatment and storage of hazardous chemicals to improve the occupational safety and health of the working environment. also, regulatory standard has to be applied to local exhaust ventilation system in small scale industry to improve the working condition.

  • PDF

Guideline on Acceptance Test and Commissioning of High-Precision External Radiation Therapy Equipment

  • Kim, Juhye;Shin, Dong Oh;Choi, Sang Hyoun;Min, Soonki;Kwon, Nahye;Jung, Unjung;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.123-136
    • /
    • 2018
  • The complex dose distribution and dose transfer characteristics of intensity-modulated radiotherapy increase the importance of precise beam data measurement and review in the acceptance inspection and preparation stages. In this study, we propose a process map for the introduction and installation of high-precision radiotherapy devices and present items and guidelines for risk management at the acceptance test procedure (ATP) and commissioning stages. Based on the ATP of the Varian and Elekta linear accelerators, the ATP items were checked step by step and compared with the quality assurance (QA) test items of the AAPM TG-142 described for the medical accelerator QA. Based on the commissioning procedure, dose quality control protocol, and mechanical quality control protocol presented at international conferences, step-by-step check items and commissioning guidelines were derived. The risk management items at each stage were (1) 21 ionization chamber performance test items and 9 electrometer, cable, and connector inspection items related to the dosimetry system; (2) 34 mechanical and dose-checking items during ATP, 22 multileaf collimator (MLC) items, and 36 imaging system items; and (3) 28 items in the measurement preparation stage and 32 items in the measurement stage after commissioning. Because the items presented in these guidelines are limited in terms of special treatment, items and practitioners can be modified to reflect the clinical needs of the institution. During the system installation, it is recommended that at least two clinically qualified medical physicists (CQMP) perform a double check in compliance with the two-person rule. We expect that this result will be useful as a radiation safety management tool that can prevent radiation accidents at each stage during the introduction of radiotherapy and the system installation process.