• Title/Summary/Keyword: Treatment Equipment

Search Result 946, Processing Time 0.032 seconds

A study on the reliability enhancement of Ultrasonic water treatment system to boiler (보일러 초음파 수처리장치의 신뢰성향상에 관한 연구)

  • Kim, Dae-Ryong;Lee, Keun-Oh
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-293
    • /
    • 2013
  • This study was carried out to diminish the formation of scale in boilers which is one of the defect elements when they are operating. The defect relating to scale can cause a fatal impact on the explosion of boilers due to the overheating of their tubes, or it can affect the flow of water inside boilers with its bad circulation and result in a disparity of water inside the equipment. Heat transfer in the scale is low comparing to the boiler material, so it can lead to energy losses and has also impact on the global warming. In 2005, the Korean government introduced a system which requires boiler users to install the equipment which can prevent or eliminate the formation of scale to improve the management of water quality in boilers. The study on the techniques for preventing or eliminating the formation of scale started in 1821 and since then subsequently there have been lots of similar studies. The first one was about the scale reduction using potato starch. Since an ultrasonic scale preventer developed by a scientist from a Russian acoustic institute was introduced in1993, a variety of equipment of this kind have been disseminated in Korea. There has been a need to demonstrate the condition for the best performances of such equipment. Boilers are mostly composed of the main body and 288 the tube with a circular curved surface. I carried out a demonstration study on a circular tube which affects the scale defect the most among the boiler components. As a result of it, I found out the fact that the ultrasonic wave needs to reach a certain level of sound pressure and frequency to affect the formation of scale.

A Research on the Perception Level of Seafarer Related Organizations in Seafarer's Actual Health Care Conditions (선원유관단체의 선원 보건의료실태 인식도 조사)

  • Kim, Jae-Ho;Jeon, Yeong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.39 no.3
    • /
    • pp.193-198
    • /
    • 2015
  • This research was conducted to provide an improvement plan concerning medical treatment on board and medical health care conditions for seafarers. 139 persons from government agencies and seafarer related organizations, who could influence the government's seafarers healthcare policy-making, were asked to fill in the questionnaire prepared for this research about their perceptive views on actual condition of health and disease management for seafarers. The results of the survey on seafarer's health care management conditions(p<0.01), health care manage ability(p<0.01), current radio emergency medical service policy(p<0.01), usefulness of on board medicine chest and medical equipment(p<0.05), and the system of the onboard medical care persons show the difference of perception level among the seafarer related organizations. But generally, the rate of negative responses was high. And this research suggests that there is an urgent need to provide portable health measurement equipment on board, reenforce regular medical examination and establish the seafarer's health promotion center for telemedicine and healthcare management(p<0.01) in order to improve the onboard medical treatment support system for healthcare of seafarers.

Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy

  • Lee, Soon Sung;Min, Chul Kee;Cho, Gyu Suk;Han, Soorim;Kim, Kum Bae;Jung, Haijo;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • Radiotherapy patients should maintain their treatment position as patient setup is very important for accurate treatment. In this study, we evaluated patient setup error quantitatively according to Cone-Beam Computed Tomography (CBCT) Gamma Density Analysis using Mobius CBCT. The adjusted setup error to the $QUASAR^{TM}$ phantom was moved artificially in the superior and lateral direction, and then we acquired the CBCT image according to the phantom setup error. To analyze the treatment setup error quantitatively, we compared values suggested in the CBCT system with the Mobius CBCT. This allowed us to evaluate the setup error using CBCT Gamma Density Analysis by comparing the planning CT with the CBCT. In addition, we acquired the 3D-gamma density passing rate according to the gamma density criteria and phantom setup error. When the movement was adjusted to only the phantom body or 3 cm diameter target inserted in the phantom, the CBCT system had a difference of approximately 1 mm, while Mobius CBCT had a difference of under 0.5 mm compared to the real setup error. When the phantom body and target moved 20 mm in the Mobius CBCT, there are 17.9 mm and 13.5 mm differences in the lateral and superior directions, respectively. The CBCT gamma density passing rate was reduced according to the increase in setup error, and the gamma density criteria of 0.1 g/cc/3 mm has 10% lower passing rate than the other density criteria. Mobius CBCT had a 2 mm setup error compared with the actual setup error. However, the difference was greater than 10 mm when the phantom body moved 20 mm with the target. Therefore, we should pay close attention when the patient's anatomy changes.

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Anti-inflammatory Effect of Arbitrary Waveform Generator Treatment in Rats

  • Kim, Myung-Gyou;Lee, Se-Na;Seo, Il-Bok;Leem, Kang-Hyun;Ham, Kee-Sun;Kim, Hye-Kyung
    • Biomedical Science Letters
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2008
  • Inflammation is the complex biological response of injured tissues to harmful stimuli. A cascade of biochemical events propagates and matures the inflammatory response, involving the local vascular system, the immune system, and various cells within the injured tissue. The immune system is often involved with inflammatory disorders, demonstrated in both allergic reactions and some myopathies, with many immune system disorders resulting in abnormal inflammation. An Arbitrary Waveform Generator (AWG) is a piece of electronic test equipment used to generate electrical waveforms for the treatment of patients. The patients with gastritis and arthritis have been known to have a relatively favorable prognosis with AWG treatment. Accordingly, we examined the effects of AWG treatment in gastritis and arthritis animal model. The compound 48/80 was used to induce animal gastritis model. The tissue malone dialdehyde (MDA) and serum histamine levels, and the activity of superoxide dismutase (SOD) in stomach tissue were measured. The tissue MDA and serum histamine levels in AWG treated groups exhibited the decreased tendency compared with control group, whereas the tissue SOD activity was slightly increased. The Freund's complete adjuvant was used to induce animal arthritis model as well. The paw edema volume and the width of ankle joint were determined. The AWG treatment significantly decreased the paw edema volume after 5th day of treatment. Although further studies should be performed to confirm the effects of AWG treatment, present study suggest that AWG treatment might be used as a complementary treatment for the gastritis or arthritis treatment.

  • PDF

Analysis about Planning Introduction PACS in Hospital Scale and Equipment Operation of Radiology Department (병원규모에서 PACS 도입 계획과 영상의학과 장비 운영에 관한 분석)

  • Seok, Jong-Min;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Jeong-Koo;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.12
    • /
    • pp.322-333
    • /
    • 2008
  • This research examined use rate and profitability of equipment in hospital scale with about 500 beds to present data including to review before introducing PACS with the checklist included in preparation and proposal based on expected profit suggested by operation department and cost and use rate of the expensive medical equipment were analyzed. It was proved that profit was generated in the research subject hospital if PACS is introduced. Three to five year of lease is proper for the purchase method of medical equipment. Profit after two year of use will surpass investment cost and generate clear profit. Based on the profit generated from operation of radiology department, the purchase amount to introduce PACS at the hospital will be retrieved after about 1.9 years for the investment. The number of reshoot test at radiology department will be decreased and film, development, and fixer will not be necessary to buy so the operation cost will be reduced. Moreover, other than actual profit increased, the hospital can improve its reputation and employees can reduce their works and get better working environment with less stress. Their job satisfaction will be increased so they can improve service quality and it is good for marketing strategy of the hospital. As a result of this research, it was proved that the small and general hospital should have expected profit with introduction of PACS and analyze its contribution to treatment service and profit after the purchase. Then, the hospital should make a proposal for introduction of the medical equipment and establish effective operation plan.

Development and Performance Evaluation of a Filtration Equipment to Reuse PFC Waste Solution Generated on PFC Decontamination (PFC 제염 시 발생된 PFC 폐액의 재사용을 위한 여과장치 개발 및 성능평가)

  • Kim Gye-Nam;Jeong Cheol-Jin;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.161-170
    • /
    • 2006
  • PFC(Perfluorocarbon) decontamination process is one of best methods to remove hot particulate adhered on the inner surface of hot cell and surface of equipment in hot cell. It was necessary to develop a filtration equipment to reuse the PFC waste solution generated on PFC decontamination due to the high cost of PFC solution and for minimization of the volume of second waste solution. The filtration equipment was developed to remove hot particulate in PFC waste solution. It was made suitable size and weight in consideration of hot cell gate and crane. And it has wheels for easy movement. Flux of the filtration equipment decreased with particulate concentration increase. It consists of pre-filter($1.4{\mu}m$) and final-filter($0.2{\mu}m$) for protection of the flux decrease along filtration time. It treatment capacity of waste solution is 0.2 L/min.

  • PDF

Development of Centrifugal Forming Process for HTS Tube Fabrication (고온초전도체 튜브 제조를 위한 원섬 성형 공정 개발)

  • 정승호;장건익
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.98-100
    • /
    • 2002
  • We developed the Centrifugal Forming Process(CFP) for HTS tube fabrication. The self-designed equipment for CFP is devided into 3 main parts depending on its role and functions. the melting part by heating of high inductive frequency, centrifugal forming part for the tube and efficient microstructure control of Bi2212 phase and molding part for tube detachment after heat treatment. In this paper we will introduce self designed Centrifugal Forming Process for HTS tube fabrication and discuss about the results related mold materials in terms of high Tc superconductor.

  • PDF

Improvement of pump motor control process to water treatment facilities by multi maneuver (멀티기동에 의한 수도사업장 펌프모터 제어방식개선)

  • Chong, Kyong-Won;Kim, Woo-Yong;Hwang, Soo-Myung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1676_1677
    • /
    • 2009
  • This paper uses the softstarter function of the inverter in the place of business where the flow control is possible, multi maneuver method as the application (with 1 inverter various pump maneuver/standstill which is soft) box the plan which prevents the small hand of the equipment which is caused by maneuver electric current presented.

  • PDF