• Title/Summary/Keyword: Treated water

Search Result 5,410, Processing Time 0.038 seconds

Evaluation on the Aggressivity of Drinking Water for Corrosion Control in Water Distribution System (상수도관로의 부식 방지를 위한 수돗물의 침식성 평가)

  • Kwak, Phill-Jae;Lee, Hyun-Dong;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.53-63
    • /
    • 1997
  • The corrosion problems in water distribution system are reduced by decreasing the agressivity of drinking water which is evaluated by marble test and saturation indices(LSI or CCPP etc.). Marble test is a reliable method to determine the actual saturation condition of treated water. This study was done to determined the aggressivity of tap water and the effectiveness of $Ca(OH)_2$ and NaOH dosage for corrosion control. The drinking water in Seoul were evaluated by marble test and Langelier Index(LSI) and Calcium Carbonate Precipitation Potential(CCPP). The results indicated that the drinking water in Seoul were undersaturated as Calcium Carbonate($CaCO_3$). The LSI and CCPP of the water treated with $Ca(OH)_2$ were higher than that of water treated with NaOH. Therefore, to increase the Alkalinity and Calcium Hardness for corrosion control in water distribution system, $Ca(OH)_2$ is more effective than NaOH.

  • PDF

Recycling of Wastepaper(XV) -Contamination of Process Water by System Closure- (고지재생연구(제15보) -제지 공정수 폐쇄화에 따른 오염 및 변화에 관한 연구-)

  • 조미선;윤혜정;류정용;신종호;송봉근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.2
    • /
    • pp.32-40
    • /
    • 2001
  • It is desirable to reduce the amounts of fresh water and reuse the recycled water in papermaking process. In an attempt to improve the efficiency of recycling water refining treatment and to enhance the productivity of OCC recycling mill, up flow anaerobic sludge blanket(UASB) reactor was developed and introduced to Korea recently. In order to maximize the operating efficiency and minimize the adverse side effects it is imperative to estimate and evaluate the total effects of new system, UASB on the whole OCC recycling process. This study was carried out with a view to investigate the effects of the high temperature and alkalinity of process water on the quality ad productivity of testliner of OCC recycling mill which is equipped with UASB reactor and almost closed. Another object of this study was searching for the best available use of UASB treated process water. The results were as follows; Reuse of UASB treated water characterized with high temp and alkalinity was useful to improve the strength and drainage properties of recycled OCC owing to its good points of promoting OCC disintegration and reducing the calcium hardness of process water. However, it might not be avoidable to induce the increase of dissolved solids in process water in accordance with direct introducing of UASB treated water into the former stage of OCC stock preparation. So it would be advisable to adopt the UASB treated water in the stage of clean, screened OCC stock.

  • PDF

Waterborne viruses in drinking water in Korea: survey 1999 for enteric virus contamination in treated water and its source water

  • Rhie KT;Yoon JD;Chung HM;Kim HS;Jeong YS
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.142-142
    • /
    • 2001
  • A national survey for enteric virus contamination in treated water and its source water was performed from March to November 1999. The water samples were subjected to virus filtration at the major water plants producing over 10$^5$ tons treated water per day. Twenty surveyed sites encompass most of heavily populated residential area except for Seoul and Pusan. (omitted)

  • PDF

Evaluation of Leaching Stability of Preservative Treated Wood in the Seawater for the use of a Fish-breeding Ground (해양어초사용을 위한 방부목재의 해수 용탈성 평가)

  • Lee, Myung Jae;Lee, Dong-Heub;Son, Dong-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.3 s.131
    • /
    • pp.53-63
    • /
    • 2005
  • This study attempted to obtain the basic data of utilizable possibility of preservative treated wood as a material used in a marine ranch. To evaluate the leaching stability of CCA-, CCFZ-, and ACQ-treated woods in seawater, the specimens treated with 2% and 3% (w/v) of CCA, CCFZ, and ACQ were exposed to deionized water, synthetic seawater and natural seawater for 41 days and then each component released was periodically determined. There was little amount of copper and chromium released from CCA-treated wood exposed in both deionized and seawater. Although relatively large amount of arsenic was released from CCA-treated wood, the release rate in seawater was lower than that in deionized water. The release rate of chromium and zinc from CCFZ-treated wood were somewhat greater in deionized water, but lower in seawater than in deionized water. Retention level and salinity of synthetic seawater had little effect on the release rate of components. The ACQ-treated wood had greater copper release than CCA- and CCFZ-treated wood, and the amount of copper released did not affected by leaching media used.

A Study on the Nitrogen Control in the Treated Leachate water by Bio-film Module System (생물막을 이용한 침출수처리수 중의 질소제어에 관한 연구)

  • 최규철;이규성;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.71-76
    • /
    • 1996
  • Bio-film module system was applied to the treated leachate water that priorly had been treated with biological nitrification process. The experiments were performed in the laboratory and treated leachate water treatment facility. Experimental results obtained from laboratory conditions and nitrogen removal efficiencies were averaged 90% for 1 hr.

  • PDF

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.

Comparison of Household Trihalomethanes (THMs) Exposure Associated with Use of Municipal Tap Water Treated with Chlorine or Ozone-Chlorine (염소살균과 오존-염소살균 수도수의 사용과 관련한 가정 트리할로메탄 노출 비교평가)

  • Jo, Wan Geun;Gwon, Gi Dong;Dong, Jong In;Jeong, Yong
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.627-635
    • /
    • 2004
  • Evaluated were household THMs exposure associated with the use of municipal tap water treated with chlorine and with ozone-chlorine. The current study measured the THMs concentrations in the tap water and indoor and outdoor air in the two types of household, along with an estimation of THMs exposure from water ingestion, showering, and the inhalation of indoor air. Chloroform was the most abundant THMs in all three media, yet no bromoform was detected in any sample. Contrary to previous findings, the fall water THMs concentrations exhibited no significant difference between the chlorine and ozone-chlorine treated water. However, the spring median chloroform concentration in the tap water treated with chlorine (17.6 ppb) was 1.3 times higher than that in the tap water treated with ozone-chlorine (13.4 ppb). It is suggested that the effects of the water parameters should be considered when evaluating the advantage of ozone-chlorine disinfection for THMs formation over chlorine disinfection. The indoor air THMs concentration trend was also consistent with the water concentration trend, yet the outdoor air THMs concentrations did not differ significantly between the two types of household. The indoor to outdoor air concentration ratios were comparable with previous studies. The THMs exposure estimates from water ingestion, showering, and the inhalation of indoor air suggested that, for the residents living in the surveyed households, their exposure to THMs in the home was mostly associated with their household water use, rather than the indoor air. The THMs exposure estimates from tap water ingestion were similar to those from showering.

Space Charge Phenomena in Polyimide Films and Effects of Absorbed Water (폴리이미드 박막의 공간전하현상 및 수분의 영향)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.82-85
    • /
    • 2008
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

Application of Agricultural Cultivation Paper Treated with Water Repellent (발수제를 적용한 농산물 재배용지의 제조)

  • Kim, Kang-Jae;Jung, Jin-Dong;Ahn, Eun-Byeol;Eom, Tae-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.4
    • /
    • pp.102-108
    • /
    • 2015
  • Agricultural cultivation papers treated with water repellent were investigated in order to analyse mechanical properties and durability. The water repellency was optimal when papers are treated with Wb and Sa water repellents. Also, WCPs with 5% water repellent were more effective than those of 3 and 10%. In addition, water repellency of WCPs with Wb and Sa water repellents were kept constant in correlation with aging time. Finally, WCP with Wb water repellent possesses efficiency in terms of mechanical properties and durability.

Dimensional Stability of Korean Red Pine Treated with Water Repellents (발수제 처리 소나무재의 치수안정성)

  • Han, Gyu-Seong
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • The objective of this study was to investigate the influence of the water repellents' treatment on the water absorptivity and the dimensional stability of Korean red pine wood(Pinus densiflora). The alkylketene dimer(AKD), fluororesin emulsion(Wood-seal, WS), and paraffin wax emulsions(PW25, PW40, and PW1200) were used as water repellents. PW40 and WS were proved as excellent water repellents for pine wood, because the samples treated with these agents showed high contact angles and large reduction in water absorptivities. Also, the dimensional stability(antiswelling efficiency) of pine wood was considerably improved by water repellents treatments, such as PW40 and WS at the pressure of 2MPa. The water repellent treated woods with WS, PW40, and PW1200 at the pressure of 2MPa were relatively stable to the wet-dry cyclic leaching test.

  • PDF