• Title/Summary/Keyword: Treated sewage

Search Result 244, Processing Time 0.037 seconds

Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment (수평 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리)

  • Seo Jeoung-Yoon;Kim Ean-Ho
    • KSBB Journal
    • /
    • v.21 no.1 s.96
    • /
    • pp.28-33
    • /
    • 2006
  • A sewage was treated using a horizontal flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^2$ day. The filtering height of the reed bed was 100 cm and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite : $0.5{\sim}1mm$ and $1{\sim}3mm$ in diameter. Annual average removal efficiency was SS $88.5%,\;COD_{cr},\;86.1%,\;COD_{Mn}\;81.0%,\;T-N\;48.6%,\;NH_4^+-N\;97.1%$ and T-P 42.8%. T-N of effluent was mostly $NO_3^--N$ and the concentration of $NO_2^--N$ in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change.

Methane Production from the Mixture of Paperboard Sludge and Sewage Sludge in an Anaerobic Treatment Process (판지슬러지와 하수슬러지를 이용한 혐기성 처리 공정에서 메탄 생산)

  • Choi, Suk Soon;Lee, Hyun Min;Jeong, Tae-Young;Yeom, Sung Ho
    • Applied Chemistry for Engineering
    • /
    • v.23 no.2
    • /
    • pp.228-231
    • /
    • 2012
  • In this work, the mixture of sewage sludge incubated in an anaerobic bioreactor for 35 days and paperboard sludge was treated in a batch anaerobic digester equipped with a ultrasonicator, and methane production during the treatment was investigated. The Soluble Chemical Oxygen Demand (SCOD) increased with increasing the amplitude of ultrasonicator, which help solubilizing paperboard sludge more effectively. The optimum amplitude of ultrasonicator for the enhancing methane productivity was found to be $142.5\;{\mu}m$ and the methane production amount increased as the anaerobic digestion period became longer. In addition, the anaerobic digestion was performed with various biomass (6000, 9000 and 12000 mg/L) and methane production increased with higher cell mass. These results will be used as valuable data to enhance the methane production from anaerobic digestion of the high concentration of organic wastes containing the paperboard sludge and sewage sludge.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Review of the Agricultural Water Quality Standards through Rice Culture with Treated Sewage Irrigation (오수처리수 관개 벼재배를 통한 농업용수 수질기준의 검토)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.2
    • /
    • pp.44-54
    • /
    • 1999
  • Agricultural water quality standards were reviewed through rice culture using treated sewage irrigation . The seqage from school building of Konkuk University was treated by a constructed wetland system, and theeffluent of the systeml was irrigated for rice culutre after nutrient concentration adjusted by dilution. Average concentration of COD, SS, T-N and T-P in irrigated water was 22.3mg/$\ell$, 6.5mg/$\ell$, 25.8 mg/$\ell$and 2.2mg/$\ell$, respectively. Treatment include irrigation of adjusted effluent with conventional fertilization (TWCF), adjusted effluent with no fertilization (TWNF). and effluent of the wetland system as it was with no fertilization (SWNF). These treatment plots were compared with control plot irrigated by tap water with conventional fertilization (CONTROL). Other environmentals for rice culture were identical for all the plots. Among them, TWCF showed the best growth rate and the highest yield, and constituents in the harvested rice showed not much difference among them. Which implies that irrigation with relatively high nutrient concentration compared to the current water quality standards may cause no adverse effect on rice culture and could be even beneficial . Although T-N for this study was 25 times greater than the current standards, rice culture wasnot adversely affected by irrigatino water quality and even beeter results were observed than the CONTROL. It could be mistakenly that clean irrigation water produces better agricultural product, however, it is not necessarily true. Irrigation water with moderate nutrient concentration can enhance the plant growth, and better result might be expected. Therefore, peer review and modification if necessary are needed to the current agricultural water quality standards, especially for the nutrient components.

  • PDF

Sewage Treatment Using a Double Media Reed Constructed Wetland (복층여재 갈대 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.379-388
    • /
    • 2014
  • A sewage was treated using a serially combined vertical(VFCW) and horizontal flow double media (sand and zeolite for VFCW and sand and waste oyster-shell for HFCW) reed constructed wetland(HFCW) with intermittent feeding (see Fig. 1). The sewage was fed into the reed constructed wetland for 10 minutes every 6 hours at the hydraulic load of $314L/m^2{\cdot}day$. The summarized results were as follows: pH values in the effluent depended very heavily on oyster-shell height filled in the HFCW. They were maintained at less than pH 6.24 when the height of the oyster-shell layer was 200 mm. Influent DO(oxygen demand) values(average 0.19 mg/L) were increased in the VFCW(average 7.65 mg/L) and decreased again in the HFCW(average 6.49 mg/L). They were higher in the winter than in the summer. The OTR(oxygen transfer rate) was $57.15g\;O_2/m^2{\cdot}day$ in the VFCW and $5.65g\;O_2/m^2{\cdot}day$ in the HFCW. The removal efficiency of $NH_4{^+}$-N was 80.17%(6.01 $NH_4{^+}$-N mg/L in the effluent). It was lower than that in the case where only zeolite was filled in the reed constructed wetland. But it was expected that treated sewage effluent using a double media reed constructed wetland with 300 mm zeolite layer could stably meet the Korean treated sewage effluent standard(20 mg T-N/L). Average removal efficiencies were SS 88.09%, BOD 88.12%, $COD_{Cr}$ 83.11%, $COD_{Mn}$ 85.58%, T-N 57.21%, $NH_4{^+}$-N 80.17%, T-P 86.73%. Nearly, The concentration of $NO_3{^-}$-N in the effluent of the VFCW was decreased in that of the HFCW. More than half of T-N in the effluent was $NO_3{^-}$-N(7.92 mg/L) but the concentration of $NO_2{^-}$-N in the effluent was average 0.90 mg/L. The removal efficiencies of T-P were 93.24%, 86.30% and 55.44% at the height of the oyster-shell-filled constructed wetland of 800 mm, 500 mm and 200 mm, respectively and therefore, they were proportional to oyster-shell height filled in the HFCW.

A Study on the Adsorption of Organophosphorus Pesticides Applying Sewage Sludge to Soil Amendment (하수슬러지의 토양개량재 적용시 유기인계 농약의 흡착 능력에 관한 연구)

  • 임은진;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.95-103
    • /
    • 2004
  • This study has been assessed the influence of applying sewage sludge to soil amendments on the sorption properties, and leaching potential of three commonly used organophosphorus pesticides, Diazinon, Fenitrothion, and Chlorpyrifos. A sandy soil with a low content of organic carbon was treated with sewage sludge with a ratio sandy soil sludge ratio of 30:1. The sorption was determined with the batch equilibrium technique. The sorption isotherms could be described by Freundlich equation. The Freundlich constant, K value which measures sorption capacity, were 3.97, 9.94, 22.48 for Diazinon, Fenitrothion, Chlorpyrifos in non-amended soil. But in amended soil, K value was 12.58, 28.47, and 61.21 for Diazinon, Fenitrothion, and Chlorpyrifos. The overall effect of sewage sludge addition to soil was to increase pesticides adsorption, due to the high sorption capacity of the organic matter. The effect of sludge on the leaching of pesticides in the soil was studied using packed soil columns. Total recoveries of pesticides in soil and leachate with leaching in soil column, were in the range of about 73∼84%, was reduced with the passage of time. Diazinon moved more rapidly than Chlorpyrifos in the unamended soil due to greater sorption and lower water solubility of Chlorpyrifos. Total amounts of pesticides leached from the sewage sludge amended soils were significantly reduced when compared with unamended soils. This reduction may be mainly due to and increase in sorption in amended soils, as a consequence of the increase in the organic matter content.

Toxicity Assessment of the Soil by Bioassay Following a Long-Term Application of Sewage Sludge (생물검정법을 이용한 하수슬러지 장기연용 토양의 독성평가)

  • Nam, Jae-Jak;Lee, Seung-Hwan;Kwon, Soon-Ik;Hong, Suk-Young;Lim, Dong-Kyu;Koh, Mun-Hwan;Song, Beom-Hun
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • Bioassay was employed to assess toxicity of soil which had been treated with sewage sludges for seven years. The $Microtox^{(R)}$ and root elongation test of lettuce (Lactuca Sativa.) elucidated that the intensity of soil toxicity was closely related with the types and amount of sewage sludges applied. Both bioassay methods proved to be useful in an assessment of soil toxicity and were consistent to some extent with the conventional chemical analysis methods. $EC_{50}$ values resulted from $Microtox^{(R)}$ were highly correlated with concentration of heavy metals in soils amended with sewage sludges : Cu ($r^2=\;0.86^{**}$), Cr ($r^2\;=\;0.84^{**}$), Ni ($r^2\;=\;0.83^{**}$), and Zn ($r^2\;=\;0.69^{**}$). This demonstrated that both bioassay techniques could be employed as tools for soil toxicity assessment when the soil was exposed to solid wastes such as sewage sludge.

Analysis on Heat Transfer Coefficient of The Fluidized - Bed Combustion for Management of Sludge (슬러지 처리를 위한 유동층 연소로의 열전달률 해석)

  • Kim, Seong-Jung;Lee, Je-Hak
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.27-33
    • /
    • 2012
  • According to the statistics of the Ministry of Environment, the emission of sewage sludge is increased by 7~9% yearly. In the future, it will be increased continuously because of extension of sewage disposal plants, high class treatment for removing nitrogen and phosphorus. Until now, we have depended on reclamation for lots of quantity and some part has been treated by ocean emission. But, direct reclamation of organic waste will be prohibited and even ocean emission will be prohibited now, so the treatment of sludge is put on emergency alert. Bio-gas can be produced by applying anaerobic digestion method for the recycling or refuse derived fuel can be conducted by applying carbonization method. However, the process is difficult, causes bad smell and makes it the second waste, so it cannot be practical method in fact. This study applied a fluidized bed combustor for sewage sludge treatment technologies that can actually take advantage of key technologies in order to verify its purpose is to demonstrate selected. If applying the fluidized bed combustor, it can be easily utilized as the replaced resource of energy(fuel) in the countries whose energy resources are insufficient, like our country. Especially, if applying only original strengths of the fluidized bed combustor sufficiently, the sewage sludge can be treated simply, eco-friendly, sanitarily and economically. Particularly, it is verified as the energy technology suitable for government's green growth policy.

Studies of Pretreatment Mehtods for Additional Reduction of Sewage Sludge (최종 하수처리장 슬러지의 추가감량을 위한 슬러지 전처리 연구)

  • Kim, Seogku;Kim, Jahyun;Lim, Junhyuk;Lee, Jeakun;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.10
    • /
    • pp.15-21
    • /
    • 2014
  • In this study, biochemical methane potential test was conducted to estimate ultimate methane and carbon dioxide yield for anaerobic digestion and pretreatment with sewage sludge cake. Two of 0.2 % TS of sewage sludge cakes were treated with 5M NaOH or sonication of 0.51 W/mL during 30 min respectively. Another sample was treated simultaneously with NaOH and sonication in same condition. Then, initial soluble COD increased from 33.1 mg/L to 494 mg/L. After BMP test, methane production ranged from 3.12 and 84.2 mL $CH_4$ per g of Volatile Solid (VS) and 9.2 and 13.5 mL $CO_2$ per g of Volatile Solid (VS) for carbon dioxide. In other tests, injection of nutrient media or sludge supernatant produced 73.1 and 73.8 mL $CH_4$ per g of Volatile Solid (VS) and 11.2 and 13.6 mL $CO_2$ per g of Volatile Solid (VS) respectively. When BMP test finished, 62 % of initial volatile solids decreased to 33.8~45.4 %. Simultaneous pretreatment increased soluble COD, reduction rate of volatile solids and digestion efficiency than those for alkaline and ultrasonic pretreatment.

Enhancement of Dewaterability of Sewage Sludge by Ultrasonification and Electric Field Treatment (초음파와 전기장 처리에 의한 하수슬러지 탈수성 향상)

  • Mo, Woojong;Han, Jisun;Ahn, Changmin;Yoon, Soonuk;Seok, Heejung;Kim, Changgyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2013
  • The sludge disposal is a major economic factor in the sewage treatment facility operation. Moreover, since the ocean dumping will be prohibited by Korean environmental law from 2013, sludge should be eliminated or sludge volumetric reduction should be performed urgently. In this study, improvement of the sewage sludge dewaterability was investigated by ultrasound and electric field treatment. Sludge was treated by a single or in combination of either the electric field or ultrasound on a pilot pretreatment facility, then it was dewatered by lab-scale filter press. The operating input energy of ultrasound device was varied from 225~1,200 kJ/L and electric field device was varied from 4.5~24 kJ/L. The water contents of dewatered sludge cake treated with ultrasound (1,200 kJ/L) and combination of ultrasound/electric field (1,224 kJ/L) were decreased 10~12% by comparing non-treated sludge. At that time, water contents were 65~66%. The combination treatment of ultrasound/electric field was effective to reduce water content of dewatered sludge cake, however, water content was not changed by a single treatment of electric field because of low energy density.