Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment

수평 흐름 제올라이트 갈대 여과상에 의한 생활하수 처리

  • Seo Jeoung-Yoon (Department of Environmental Engineering, College of Engineering, Changwon National University) ;
  • Kim Ean-Ho (Department of Environmental Engineering, College of Engineering, Changwon National University)
  • Published : 2006.02.01

Abstract

A sewage was treated using a horizontal flow zeolite-filled reed bed. The sewage from the student dormitory of Changwon National University was fed into the reed bed for 10 minutes every 6 hours at the hydraulic load of $314L/m^2$ day. The filtering height of the reed bed was 100 cm and the zeolite mixture was filled in the reed bed. The mixture consisted of the same volume of two types of zeolite : $0.5{\sim}1mm$ and $1{\sim}3mm$ in diameter. Annual average removal efficiency was SS $88.5%,\;COD_{cr},\;86.1%,\;COD_{Mn}\;81.0%,\;T-N\;48.6%,\;NH_4^+-N\;97.1%$ and T-P 42.8%. T-N of effluent was mostly $NO_3^--N$ and the concentration of $NO_2^--N$ in effluent was lower than 0.1 mg/L. All removal efficiencies did not show a remarkable seasonal change.

제올라이트로 충진된 수평 흐름 갈대 여과상에 실제하수를 간헐적으로 주입하면서 처리효율을 조사하였다. 여과상 표면적 $m^2$당 1일 314 L의 하수가 6시간마다 10분 동안 간헐적으로 주입되었다. 처리수의 pH는 원수보다 감소하였으며, 용존산소 농도는 원수보다 증가하였다. 수평 흐름 여과상에서 각 항목별 연중 평균 처리효율은 SS $88.5%,\;COD_{cr},\;86.1%,\;COD_{Mn}\;81.0%,\;T-N\;48.6%,\;NH_4^+-N\;97.1%$, T-P 42.8%이었다. 수평 흐름 여과상에서 처리수 중 T-N의 대부분은 $NO_3^--N$이었으며 $NO_2^--N$의 농도는 0.10 mg/L 이하이었다. 처리효율의 계절적 차이는 없었다.

Keywords

References

  1. An, T. -S. (1997), On the artificial wetland for water quality improvement in golf course, In Research Bulletin, Yongkang Foundation, 347-372
  2. Kim, Y., D. -S. Kim, S. -B. Jang, and S. -Y. Park (1996), Studies on the removal of metal ions with domestic Pohang zeolite and synthetic zeolite, J. of KSEE. 18(5), 578-589
  3. Yoo, S. -U. (1997), Process development for simultaneous removal of nitrogen and phosphorus using natural zeolite, Institute of Samsung Mulsan Construction, Ministry of Environment, Korea
  4. Noh, J. H. and K. U. kim (1988), Diabenetic alteration of tertiary formation in Gimpo Area, J. Ceol. Soc. Korea 24(4), 397-416
  5. Noh, J. H. and J. R. Boles (1989), Diagenetic alteration of perlite in Guryongpo area, Republic of Korea, Clays Clay Miner. 37(1), 47-58 https://doi.org/10.1346/CCMN.1989.0370106
  6. Lee, J. -H., H. -U. Nam, Y. -G. Kim, and T. -J. Park (1998), Characteristics of phosphorus removal from municipal wastewater treatment using a column fixed film reactor (CFFR) process, J. KSWO. 14(2), 129-136
  7. Hegemann, W. (1997), Abwasserentsorgung im Duenn Besiedelten Flaechenland Brandenburg, Arch. fuer Nat.-Lands.-, Vol. 00, 1-12
  8. Hegemann, W. (1996), Neue Entwicklung in der Klaertechnik - Hightech und/oder Einfachverfahren, TU International, Nr. 34/35, 18-20
  9. Alder, P. R., S. T. Summerfelt, D. M. Glenn, and F. Takeda (1996), Evaluation of a wetland system designed to meet stringent phosphorus discharge requirement, Water Environment Research 68(5), 836-840 https://doi.org/10.2175/106143096X127839
  10. Seidel, K. (1976), Ueber die Selbstreinigung natuerlicher Gewaesser, Naturwissenschaften 63, 286-291 https://doi.org/10.1007/BF00624016
  11. Seo, J. -Y. (2002), Treatment of artificial sewage using a zeolite column, Korean Jorunal of Environmental Agriculture 21(3), 178-188 https://doi.org/10.5338/KJEA.2002.21.3.178
  12. Seo, J. -Y., T. -H. Kim, and M. S. Choi (2003), Vertical flow zeolite-filled reed bed for treatment of artificial sewage with intermittent feeding, Kor. J. Biotechnol.. Bioeng. 18(2), 140-144
  13. Seo, J. - Y. and M. S. Choi (2003), Horizontal flow zeolite-filled reed bed for treatment of artificial sewage with intermittent feeding, Kor. J. Biotechnol. Bioeng. 18(6), 506-510
  14. Dongwha Technology (1999), Korea Standard Methods of Waste and Wastewater
  15. Standard Methods for the Examination of Water and Wastewater, 18th Ed., APHA, AWWA, WPCF
  16. Park, C. S., S. G. Chung, G. M. Han, M. H. Song, Y. B. Chun, Y. G. CHoi, J. H. CHung, C. N. OK, S. U. Jang, J. G. Chung, J. B. Shin, M. Y. Lee, and D. M. Lee, (1996), Soil Test Methods, Saeron
  17. Chung, D. Y. et al. (2002), Development of an environmentally friendly sewage treatment model with water plant and sand for small communities, Ministry of Environment(final report), Korea
  18. Kraft, H. (1987), Pflanzenklaeranlagen aus Oekologischer Sicht, ATV-Fortbildungskurs E/5, 18. 20.3.1987 in Fulda, Abwasserbeseitung in Laendlichem Raum
  19. Wissing, F. (1995), Wasserreinigung mit Pflanzen, E.U. Verlag Eugen Ulmer
  20. Seo, J.- Y. (2002), Sewage treatment by a reed bed system filled with zeolite, KOSEF No. 986-1200-004-2, KOSEF
  21. ATV-Regelwerk Abwassrer-Abfall (1989), Behandlung von haeuslichem Abwasser in Pflanzenbeeten, ATV-Hinweisblatt H 262, Gesellschaft zur Foederung der Abwassertechnik e. V
  22. Platzer, C. (1998), Entwicklung eines Bemessungsansatzes zur Stickstoffelimination in Pflanzenklaeranlagen, Berichte zur Siedlungswasserwirtschaft Nr. 6, Doctorial dissertation of Technical University Berlin
  23. Bahlo, K. (1997), Reinigungsleistung und Bemessung von vertikal durchstroemten Bodenfiltern mit Abwasserrezirkulation', Fachbereich Bauingenieur- und Vermessungswesen der Universitaet Hannover, doctorial dissertation
  24. Fehr, G. and H. Schuette, (1990), Leistungsfaehigkeit intermittirend beschickter, bepflanzter Bodenfilter, 21. Wassertechnische Seminar, Pflanzenklaeranlagen - Besser Als Ihr Ruf?, Institut fuer Wasserversorgung, Abwasserbeseitigung und Raumplanung der Technischen Hochschule Darmstadt. 197-225