• Title/Summary/Keyword: Treadmill exercise testing

Search Result 14, Processing Time 0.021 seconds

Non-Exercise VO2max Estimation for Healthy Young Adults (젊은 정상성인의 비운동 VO2max 추정식)

  • Lee, Jung-Ah;Cho, Sang-Hyun;Yi, Chung-Hwi;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.12 no.3
    • /
    • pp.74-83
    • /
    • 2005
  • The purpose of this study was to produce the regression equation from non-exercise $VO_{2max}$ of healthy young adults and to develop a maximal oxygen consumption ($VO_{2max}$) regression model. This model was based on heart rate non-exercise predictor variables (rest heart rate, maximal heart rate/rest heart rate), as an extra addition to the general regression which can reflect an individual's inherent or acquired cardiorespiratory fitness. The subjects were 101 healthy young adults aged 19 to 35 years. Exercise testing was measured by using a Balke protocol for treadmill and indirect calorimetry. The prediction equation was analyzed by using stepwise multiple regression procedures. The mean of $VO_{2max}$ was $39.02{\pm}6.72\;m{\ell}/kg/min$ (mean${\pm}$SD). The greatest variable correlated to $VO_{2max}$ was %fat. The predictor variable used in the non-exercise $VO_{2max}$ included %fat, gender, habitual physical activity and $HR_{max}/HR_{rest}$. The non-exercise $VO_{2max}$ estimation was as follows: $VO_{2max}$($m{\ell}/kg/min$)=55.58-.41(%fat)+.59(physical activity rating)-2.69($HR_{max}/HR_{rest}$)-5.36 (male=0, female=1); (R=.85, SEE=3.64, R2=.72: including heart rate variable); $VO_{2max}$($m{\ell}/kg/min$)=48.47-.41(%fat)+.45(physical activity rating)-5.12 (male=0, female=1); (R=.84, SEE=3.74, R2=.70: with the exception of heart rate variable). As an added heart rate variable, there was only a 2% coefficient of determination improved. Therefore, these results demonstrated that heart rate variable correlation with a non-exercise regression model was very low. In conclusion, for healthy young korean adults, those variables that can affect non-exercise $VO_{2max}$ estimation turned out to be only % fat, gender, and physical activity. We suggest that further research of predictor variables for non-exercise $VO_{2max}$ is necessary for different patient groups who cannot perform maximal exercise or submaximal exercise.

  • PDF

Changes in Physiological Responses by the Pressure of Non-Elastic Corset (비신축성 코르셋의 의복압으로 인한 생리적 반응의 변화)

  • Na, Young-Joo;Kim, Yang-Hee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.6
    • /
    • pp.943-951
    • /
    • 2011
  • The purpose of this study is to analyze the physiological effects of non-elastic corset on women's health and pain through measuring the clothing pressure, subjective pressure sensation, blood velocity and metabolism. 5 women in their twenties were picked as our subjects, their average size being 85cm at bust girth, 69 cm at waist girth. With the subjects each wearing a corset, we are testing in artificial environment with a treadmill according to the planned exercise procedures. The average pressure of the corset is 0.938 kPa (maximum 3.006 kPa at 45 degree front bowing), which is 10.2 times higher than the control group, averaging from 9.3 times higher at resting, 11.4 times at walking, 11.1 times at running. The effect of corset pressure on the physiological responses of the body is increased more when exercise than when resting. Clothing pressure increased in the order of the postures: sitting > standing with 45 degree bowing > standing. They experienced a high level of tighten discomfort of 5.6 in the scale of 1.0 to 7.0 due to the high pressure of the corset when resting, after intense exercise the level increased to 6.0, while without corset the level increased 1.7 to 2.2. With corset on, the blood circulation did not increase even though when the body exercised and blood flow became unbalanced making great gaps between both at the right and left finger tips. Perspiration of chest and back decreased 37.3% when wearing corset; 27.5% at resting, 56.7% at walking, 25.8% at running, and 39.0% at recovery. With corset on oxygen consume and metabolism increased 9.0%, 7.9%, respectively, which means the corset makes the body uncomfortable. Lung volume exchange VE decreased almost 4.1~7.3% with corset on and $VCO_2/VO_2$, RER and total volume in lung, VT also decreased too, which means the digestion of stomach and lung function are inhibited due to the high corset pressure.

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF

Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask (작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향)

  • Lee, Jinsil;Cho, Sunhee;Yun, Jungmin;Kim, Min-Sun;Park, Jaekyu;Choe, Jaeho
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.301-310
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using 'Respirator Fit Tester 8038' which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(${\alpha}=0.01$). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.