• Title/Summary/Keyword: Tray thickness

Search Result 37, Processing Time 0.032 seconds

A Numerical Study on the Characteristic of Airflow and Aeroacoustic Noise in DVD Drive (DVD 드라이브 내에서의 유동 및 유동소음 특성에 관한 수치적 연구)

  • Yoo, Seung-Won;Lee, Jong-Soo;Min, Oak-Key;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.759-764
    • /
    • 2000
  • The accurate prediction of aeroacoustic analysis is necessary for designers to control and reduce airflow-induced sound pressure levels in high speed rotating DVD drives. This paper focuses on the numerical prediction of airflow-induced sound in DVD drives. Computational fluid dynamics(CFD) is first conducted to evaluate flow field characteristics due to the high-speed disk rotation, and to support the acoustic analysis. The acoustic analogy based on Ffowcs Williams-Hawkings(FW-H) equation is adopted to predict aeroacoustic noise patterns. The integral solution for quadrupole volume source is included to identify the turbulence noise generated inside the DVD tray. The strength of sound pressure level with respect to rotating speed is discussed to meet upfront demand on the high fidelity product development. The present study also focuses on the noise directivity and examines how much the sound noise is sensitive to change in rotating speed. Near-field noise is strongly affected by the flow field characteristic, which is caused by the complex shape of the tray. For a mid-field, the quadrupole noise play as a counterpart of thickness noise or loading noise, so it generates different sound noise patterns compared with those in the near field.

  • PDF

Quality Changes in Mushrooms (Agaricus bisporus) due to Their Packaging Materials during Their Storage (포장재에 따른 양송이버섯의 저장 중 품질변화)

  • Lee, Da-Uhm;Chang, Min-Sun;Cho, Sun-Duk;Jhune, Chang-Sung;Kim, Gun-Hee
    • Food Science and Preservation
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Mushrooms have a shorter shelf-life than most vegetables because of their very high respiration rates, sensitivity to enzymatic browning and susceptibility to microbial spoilage. This study was conducted to investigate effects of various packaging materials and precooling on the quality of mushrooms (Agaricus bisporus). Mushrooms were precooled at $4^{\circ}C$ for three hours and packaged using the following packaging materials; 1) polyethylene (PE) film bags of 0.03 mm thickness, 2) polypropylene (PP) film bags of 0.03 mm thickness, and 3) polystyrene (PS) tray+polyvinyl chloride (PVC) wrapper. The physiological changes (weight loss, gas composition, color, firmness, and sensory evaluation) associated with postharvest deterioration were monitored for 17 days at $10^{\circ}C$. The results showed that the PP film bag maintained quality of mushrooms most effectively, especially PP film bags inhibited decreasing firmness. The samples also exhibited smaller decreases in weight loss rate (0.57%) and Hunter L value (84.44) than PS tray+PVC wrapper (7.73%, 82.19) and PE film bags (0.89%, 82.96). Sensory evaluation level in all samples remained relatively constant during the first 5 days of storage. However, PE film bags and PS tray+PVC wrapper showed lower score of flavor, texture and color than PP film bags after 8 days of storage. This study suggested that PP film bag packaging effectively extends shelf-life of mushrooms during storage.

IN VITRO STUDY OF TOOTH TEMPERATURE CHANGE DURING POLYMERIZATION REACT10N OF THE COLD-CURED RESINS USED IN PROVISIONAL CROWN AND FIXED PARTIAL DENTURES (자가 중합 임시수복용 레진의 경화 시 외부환경 변화에 따른 치아의 온도변화)

  • Oh, Wu-Sik;Baik, Jin;Kim, Hyung-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.503-513
    • /
    • 2006
  • Statement of the problem: The cold-cured resins used in fabrication of the provisional crown and fixed partial dentures could cause pulpal damage by heat generated during exothermic polymerization reactions. Purpose: In this in vitro study investigates the how external conditions such as material of the matrix, thickness of the matrix and thickness of dentin affect the temperature of the tooth during polymerization reaction of the cold-cured resins. Material and methods : To measure the temperature of the resin, metal die was maintained to the temperature of $37^{\circ}C$ with water bath to simulate the temperature of thetooth and thermocouple was placed in the center of the metal die. Acrylic pipe was cut in height of 1, 2, 3, 6, 10 mm and placed on the metal die and mixed resin was pored in the acrylic pipe As the resin polymerized temperature was recorded with the thermometer. Temperature of the resin using matrix was recorded by using the individual tray relieved in different thickness 2, 5, 7, 10 mm. The material of the matrix was irreversible hydrocolloid impression material, vinyl polysilloxane impression material and vacuum-formed template Temperature rise of the resin using different thickness of tooth section was record ed by placing tooth section on the metal die and placing resin over the tooth section. Results : Conclusion : 1. Temperature rise increased as the thickness of the resin increased but there was no significant differences over 3 mm thickness of the resin. 2. The lowest temperature rise was showed in irreversible hydrocolloid impression material and vinyl polysilloxane impression material vacuum-formed template as in orders. 3, Temperature rise of the resin decreased regardless of the thickness of the matrix when vinyl polysilloxane impression material was used as the matrix. 4 When irreversible hydrocolloid impression material was used as matrix, the temperature rise of the resin decreased as the thickness of the matrix increased and there was no temperature rise when thickness of the matrix reached 10 mm, 5. The temperature rise of the resin did not decreased when Polypropylene vacuum-formed template was used as the matrix. 6, The temperature of the resin increased as the thickness of the dentin decreased.

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS USING HOLOGRAPHIC INTERFEROMETRY (Holographic Interferometry를 이용한 탄성 고무 인상재의 체적변화에 관한 연구)

  • Ha, Chee-Yang;Lee, Sung-Bok;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.574-592
    • /
    • 1996
  • This study investigated the time-dependent dimensional changes of elastomeric impression materials using holographic interferometry. Six commercial impression materials, Permlastic(polysulfide), Xantopren VL (condensation silicone), low and medium viscosity of Exafine, Provil (addition silicone), and Impregum(polyether), were selected. Steel plate was used as custom tray, and each impression specimen was 20 mm in width, 15 mm in length and 3 mm in thickness. Each impression material was evaluated at 30 minutes, 1, 2, 4, 6, 8 and 12 hours after setting using real-time holography. The results were as follow : 1. Xantopren VL and Permlastic showed relatively severe and continuous dimensional changes after setting. Low viscosity of Exafine, Provil, Impregum showed relatively slight dimensional changes with function of time and medium viscosity of Exafine showed almost no dimensional change from 2 hours after setting to 6 hours. 2. On initial dimensional changes within 1 hour, the amount of change in low viscosity of Exafine was the least and Xantopren VL was the largest. 3. On dimensional changes at 4 hours after setting, the amount of change in medium viscosity of Exafine was the least and tile change of Xantopren VL was the largest. 4. In overall dimensional stability during 12 hours, medium viscosity of Exafine was the most stable and Xantopren VL and Permlastic were least stable.

  • PDF

On Estimating Interception Storage Capacity of Litter Layer at Gwangneung Deciduous Forest (광릉 활엽수림의 낙엽층 차단저류능 추정에 관하여)

  • Kang, Min-Seok;Hong, Je-Woo;Bong, Ha-Young;Jang, Hye-Mi;Choi, Myung-Je;Jang, Yoo-Hee;Cheon, Jeong-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.2
    • /
    • pp.87-92
    • /
    • 2011
  • In order to better understand the role of litter layer on hydrological cycle in forest, we estimated the interception storage capacity of the litter layer at Gwangneung deciduous forest. We first made a thickness map of the litter layer at the study site based on field survey and then collected representative litter samples for the laboratory experiment. We constructed a measurement device consisting of sample tray, drain collector, tipping bucket, and a data logger. Using this device, we examined the relationship between the interception storage capacity ($C_i$) and the thickness (d) of the litter layer. For the range of d from 25 to 100 mm, there was a simple linear relationship between $C_i$ and d, which changed with the intensity of the simulated rain. The results were extrapolated to d smaller than 25 mm by considering that no interception occurs without litter layer. Overall, $C_i$ increased rapidly when d was low (< 25 mm) but the rate of increase decreased as d increased due to clumping. With an average thickness of 59 mm, the estimated $C_i$ at the site was 0.94 (${\pm}0.39$) mm. Such an interception storage capacity of the litter layer is comparable to that of the forest canopy, suggesting that the litter layer can play an important role in the forest water cycle.

Studies on the browning inhibition of yam(Dioscorea aimadoimo) during hot air dehydration (단마(Dioscorea aimadoimo)의 열풍건조 시 갈변 억제 방안 연구)

  • Chung, Yong-Yul;Jeong, Woo-Sik;Chung, Shin-Kyo
    • Applied Biological Chemistry
    • /
    • v.39 no.5
    • /
    • pp.384-388
    • /
    • 1996
  • This research was conducted to investigate the effective methods for browning inhibition on yam (Dioscorea aimadeimo) during dehydration by physical and chemical pretreatments. Moisture, crude protein, crude fiber and N-free extract contents of yam were 81.17%, 1.43%, 0.29% and 15.81%, respectively. Yams were sliced to 0.5 cm thickness and placed to single and poly layer in plastic tray, and then changes of their weights were measured during air dehydration at $50^{\circ}C,\;65^{\circ}C,\;and\;80^{\circ}C$. The dehydration time reaching to optimum moisture level for the pulverization of the yam slices were 10, 6, 3 hours(single layered) and 12, 7, 5 hours(multi layered) at the respective temperature. To inhibit browning at $80^{\circ}C$ air dehydration, water and steam blanching, microwave treatment effects were investigated on yam slices for 30 sec. and 60 sec. Steam blanching for 30 sec. was comparatively effective to inhibit browning of yam slices. Yam slices were immersed in single and combined browning inhibitor solutions and evaluated for browing degree during dehydration by the values of Hunter L, a, b and ${\Delta}E$. The most effective pretreatment to inhibit browning of yam slices was immersion In the solution containing 500 ppm of citric acid and 1000 ppm of cysteine for 1 min.

  • PDF

Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

APPLICATION OF THERMOFORMED APPLIANCES IN PEDIATRIC DENTISTRY (소아치과 임상에서의 Thermoformed Appliance의 적용)

  • Kim, Shin;Jeong, Tae-Sung;Yang, Chul-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.539-544
    • /
    • 1998
  • Thermoformed appliance, which has been recently introduced for dental usage, is an appliance made of thermoformed sheets and formed with positive or negative pressure under heat. Thermoplastic material is a kind of plastics and can be repeatedly softened by heat. It is classified into hard elastic foil, hard/soft compound foil and soft elastic foil, including BIOPLAST, BIOCRYL, IMPRELON, etc. It has been developed in 1969 and is available in various thickness, shape and color. There are two types of Vacuum former for thermoplastic materials; the pressure type and suction type. The former is much better than the latter for fabrication of various appliances due to its higher pressure. The authors have applied these appliances to some cases - chin cap, active retainer, individual Fluoride tray, mouth protector, bracket transfer mask, bruxism splint(night guard), Essix appliance - by pressure type Vacuum former($Biostar^{(R)}$). The thermoplastic appliances have numerous advantages such as simple procedure, short working time, clean and transparent product, less objectionable taste. But its outstanding advantage would be its excellent biocompatibility bacause it has no monomer and hence no tissue irritation. Although there is some limitations in its usage, it can be used widely for various purposes especaily for pediatric dentistry.

  • PDF

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF