• Title/Summary/Keyword: Transverse change

Search Result 273, Processing Time 0.028 seconds

The utility of three-dimensional models in complex microsurgical reconstruction

  • Ogunleye, Adeyemi A.;Deptula, Peter L.;Inchauste, Suzie M.;Zelones, Justin T.;Walters, Shannon;Gifford, Kyle;LeCastillo, Chris;Napel, Sandy;Fleischmann, Dominik;Nguyen, Dung H.
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.428-434
    • /
    • 2020
  • Background Three-dimensional (3D) model printing improves visualization of anatomical structures in space compared to two-dimensional (2D) data and creates an exact model of the surgical site that can be used for reference during surgery. There is limited evidence on the effects of using 3D models in microsurgical reconstruction on improving clinical outcomes. Methods A retrospective review of patients undergoing reconstructive breast microsurgery procedures from 2017 to 2019 who received computed tomography angiography (CTA) scans only or with 3D models for preoperative surgical planning were performed. Preoperative decision-making to undergo a deep inferior epigastric perforator (DIEP) versus muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap, as well as whether the decision changed during flap harvest and postoperative complications were tracked based on the preoperative imaging used. In addition, we describe three example cases showing direct application of 3D mold as an accurate model to guide intraoperative dissection in complex microsurgical reconstruction. Results Fifty-eight abdominal-based breast free-flaps performed using conventional CTA were compared with a matched cohort of 58 breast free-flaps performed with 3D model print. There was no flap loss in either group. There was a significant reduction in flap harvest time with use of 3D model (CTA vs. 3D, 117.7±14.2 minutes vs. 109.8±11.6 minutes; P=0.001). In addition, there was no change in preoperative decision on type of flap harvested in all cases in 3D print group (0%), compared with 24.1% change in conventional CTA group. Conclusions Use of 3D print model improves accuracy of preoperative planning and reduces flap harvest time with similar postoperative complications in complex microsurgical reconstruction.

Characteristics of Landslide Occurrence and Change in the Matric Suction and Volumetric Water Content due to Rainfall Infiltration (강우침투에 의한 산사태 발생 및 모관흡수력과 체적함수비의 변화 특성에 관한 연구)

  • Seo, Won-Gyo;Choi, Junghae;Chae, Byung-Gon;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.475-487
    • /
    • 2017
  • We performed landslide flume tests to analyze characteristics of landslide occurrence and change in the ground materials due to rainfall infiltration. The test apparatus is composed of flume, rainfall simulator, and measurement sensors and landslides were triggered by heavy rainfall (Intensity=200 mm/hr) sprinkled at the above of an artificial slope. The measurement sensors for matric suction and volumetric water content were installed with 3 sets at shallow (GL-0.2 m), middle (GL-0.4 m), and deep depth (GL-0.6 m) in the slope and the tests were performed with in-situ, loose, and dense condition of each weathered soils of granite, gneiss, and mudstone. The analyses show that surface erosion was dominant in initial time of the test due to heavy rainfall and then landslides occur following locally happened transverse tension cracks. The characteristics of landslide were both shallow failure because of a spread of wetting front induced by the rainfall infiltration and retrogressive failure. While the matric suction was decreased rapidly without any precursor in the soil saturation, the volumetric water content was increased gradually, reached its maximum value, and then decreased rapidly with landslide.

Change of Somatosensory Evoked Field Potential according to the Severity of Hydrocephalus in Kaolin-induced Hydrocephalus of Rats (수두증 흰쥐 모델에서 수두증 정도에 따른 체성 감각 유발 장전위의 변화)

  • Kim, Dong-Seok;Lee, Kwang-Soo;Park, Yong-Goo;Kim, Se-Hyuk;Choi, Joong-Uhn;Lee, Bae-Hwan;Ryou, Jae-Wook;Zhao, Chun-Zhi
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.5-14
    • /
    • 2000
  • Objective : Somatosensory evoked potential(SSEP) has been known to be a good method for evaluating brain stem function, but it is not sufficient to check the fine changes of cortical functions. A fine change of cortical function can be expressed with somatosensory evoked cortical field potential(SSEFP) rather than general SSEP. To confirm the usefulness of SSEFP for evaluating the cortical function, the authors simultaneously measured SSEFP and the intracranial pressure-volume index(PVI) in kaolin-induced hydrocephalic rats. Method : Hydrocephalus was induced with injection of 0.1ml kaolin-suspended solution into the cisterna magna in 60 Sprague-Dawley rats. The authors measured PVI and SSEFP 1 week after injection of kaolin-suspended solution. To evaluate the severity of induced hydrocephalus, we measured the transverse diameter of the lateral ventricle on the coronal slice of the rat brain 0.40mm posterior to the bregma. Result : The typical wave form of SSEFP in control rats showed a negative-positive complex wave at early latency. In SSEFP of normal rats, N0 is 10.0 msec, N1 15.3 msec, P1 31.2 msec and N1-P1 amplitude $15.4{\mu}V$. As hydrocephalus progressed, the peak latency of N1 and P1 were delayed. In mild hydrocephalus, negative peak waves were split. The N1-P1 amplitude was decreased only in severe hydrocephalus. The changes of the characteristics of SSEFP according to the severity of hydrocephalus were well correlated with the changes of PVI. Shunting normalized the characteristics of SSEFP in relation to ventricular sizes and PVI in hydrocephalic rats. Conclusion : SSEFP may be useful for evaluating the impairment of cortical function in hydrocephalus.

  • PDF

3-Dimensional Gait analysis and the relationship between lower limb alignment and knee adduction moment in elderly healthy women (3차원적 동작 분석기를 이용한 건강한 여자 노인의 하지 정렬 상태와 슬관절 내전 모멘트의 상관 관계에 관한 연구)

  • Cho, You-Mi;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.90-101
    • /
    • 2003
  • Gait analysis can provide a better understanding of how the alignment of the lower limb and foot can contribute to force observed at the knee. Anatomic and mechanical factors that affect loading in the knee pint can contribute to pathologic change seen at the knee in degenerative pint disease and should be considered in treatment plan. The purpose of this study is to present the gait analysis data and to determine whether there is any relationships between alignment of the lower limb, foot progression angle and knee pint moments in elderly healthy women with 3-dimensional motion analyzer. The results were as follows; 1. Cadence showed 114.8 steps/min, gait speed showed 1.05 m/s, time per a stride showed 1.06 sec, time per a step showed 0.53 sec, single-supporting phase was 0.41 sec, double-supporting phase was 0.24 sec, stride length was 1.04 m, Step length was 0.56 m. 2. According to the parameters of kinematics, the maximal knee flexion angle through swing phase showed left $46.82^{\circ}$, right $40.19^{\circ}$ and the maximal knee extension angle showed left $-1.32^{\circ}$, right $2.01^{\circ}$. knee varus showed left $26.90^{\circ}$, right $30.93^{\circ}$. 3. Moment, one of kinetic parameters of knee pint the maximal flexion moment showed left 0.363. Nm/kg, right 0.464 Nm/kg and maximal extension moment showed left 0.389 Nm/kg, right 0.463 Nm/kg. The maximal. adduction moment showed left 0.332 Nm/kg, right 0.379 Nm/kg and the maximal internal rotatory moment showed left 0.13 Nm/kg, right 0.140 Nm/kg. 4. On sagittal plane, the maximal power of knee joint showed left 0.571 J/kg, right 0.629 J/kg. On coronal plane, the maximal power of knee joint showed left 0.11 J/kg, right 0.12 J/kg. On transverse plane, the maximal power of knee joint showed left 0.058 J/kg, right 0.072 J/kg. 5. The subject who had varus alignment of the lower extremity had statistically higher in knee adduction moment in mid stance phase. 6. The subject who had large foot progression angle had statistically lower in knee adduction moment in late stance phase. A relationship was observed between the alignment of the lower extremity and the adduction moment of the knee joint during stance phase. Hence, we need some research to figure, out the change of adduction moment according to the sort of knee joint osteoarthritis and the normal geriatrics as well. And we also require more effective, specific therapeutic program by making use of those background of researches.

  • PDF

Comparison of the Morphometric Changes in the Cervical Foramen: Anterior Cervical Discectomy and Fusion versus Posterior Foraminotomy (전방 경유 디스크 절제술 및 유합술과 후방 추간공 절제술에서의 경추 추간공의 형태학적 변화 비교)

  • Chung, Sung-Soo;Sun, Woo-Sung;Chung, Jong-Chul;Heo, Ki-Sung;Kim, Hyun-Min
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.512-518
    • /
    • 2021
  • Purpose: This study compared the change in foraminal space on magnetic resonance imaging (MRI) and the clinical outcome after anterior cervical discectomy and fusion (ACDF) versus foraminotomy in cervical foraminal stenosis. Materials and Methods: A retrospective case-control study was conducted from January 2018 to March 2019 on 186 patients who underwent ACDF and foraminotomy. One hundred and two cases were selected considering age, sex, and body mass index. MRI was performed before and on the 5th day after surgery to compare the changes in the foraminal diameter between the ACDF group (group A-51) and foraminotomy group (group B-51). Results: Between groups A and B, the average change in foraminal vertical diameter was 1.7 mm and 1.2 mm, respectively; group A was 0.5 mm larger difference (p=0.042). The average change in foraminal transverse diameter was 1.2 mm and 1.8mm, respectively; group B showed a 0.6 mm larger change (p=0.21). Both the neck disability index (NDI) and Japanese orthopaedic association (JOA) scores improved in both groups. Group A showed more improvement, but there was no significant difference (p=0.356, p=0.607, respectively). Conclusion: Foraminotomy is a useful option for patients with foraminal stenosis of the cervical spine because it showed comparable clinical and morphological results to ACDF and could minimize motion segment loss and muscle and ligament damage.

The Clinical Analysis of Lateral Discoid Meniscus in Adults Over 40 years old (40세 이상에서 발견된 외측 원판형 연골의 임상분석)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Jung, Hyo-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2006
  • Purpose: The purpose of this study was to analyze the clinical results of symptomatic lateral discoid meniscus found in adults over 40 years old. Materials & Methods: From March 1994 to March 2004, 53 cases treated for lateral discoid meniscus in 48 patients aged over 40 years with the mean age $48.4(40{\sim}62)$ who were followed up more than 1 year, were analyzed by physical findings, simple X-ray, MRI and arthroscopic exam. Results: Most of the cases (42 cases, 79.2%) had symptoms for less than 1 year duration. 26 cases(49.1 %) out of 53 had trauma history. Simple radiologic evaluation showed that lateral condylar abnormality such as the flattening of lateral femoral condyle, marginal osteophytes, and subchondral sclerosis was seen in 37cases(69.8%). Also medial condyle showed degenerative changes in 16 cases (30.2%). Tear of discoid meniscus in 45 cases(84.9%) were examined by arthroscope and tear was not detected in 8 cases(15.1%). Type of tear was complex(18 cases), longitudinal(12 cases), horizontal(11 cases) and transverse(4 cases). Concomitant medial meniscal rupture was found in 7 cases(13.2%). The simple procedure done was reshaping(46 cases), subtotal resection(5 cases), total resection(1 case) and meniscal repair after reshaping in 6 cases, and arthroplasty was performed after arthroscopic examination in 1 case. Conclusion: Onset of symptom in adult lateral discoid meniscus is usually traumatic in origin. Most cases showed radiologic abnormality such as degenerative change in lateral condyles as well as medial condyles and the results of preservative surgical treatment was the most preferred option in most patients.

  • PDF

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF

Impedance-based Long-term Structural Health Monitoring for Jacket-type Tidal Current Power Plant Structure in Temperature and Load Changes (온도 및 하중 영향을 고려한 임피던스 기반 조류발전용 재킷 구조물의 장기 건전성 모니터링)

  • Min, Jiyoung;Kim, Yucheong;Yun, Chung-Bang;Yi, Jin-Hak
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5A
    • /
    • pp.351-360
    • /
    • 2011
  • Jacket-type offshore structures are always exposed to severe environmental conditions such as salt, high speed of current, wave, and wind compared with other onshore structures. In spite of the importance of maintaining the structural integrity for offshore structure, there are few cases to apply structural health monitoring (SHM) system in practice. The impedance-based SHM is a kind of local SHM techniques and to date, numerous techniques and algorithms have been proposed for local SHM of real-scale structures. However, it still requires a significant challenge for practical applications to compensate unknown environmental effects and to extract only damage features from impedance signals. In this study, the impedance-based SHM was carried out on a 1/20-scaled model of an Uldolmok current power plant structure under changes in temperature and transverse loadings. Principal component analysis (PCA) was applied using conventional damage index to eliminate principal components sensitive to environmental change. It was found that the proposed PCA-base approach is an effective tool for long-term SHM under significant environmental changes.

Proposition of Improved Semi-Analytical Relationship considering Response Characteristics of Buried Pipeline (지중매설관로의 거동특성을 반영한 개선된 해석적 관계식의 제안)

  • 김태욱;임윤묵;김문겸
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.37-46
    • /
    • 2003
  • Response analysis of buried pipeline subjected to permanent ground deformation(PGD) due to liquefaction is mainly executed by use of numerical analysis or semi-analytical relationship, Especially for the semi-analytical relationship considering transverse PGD, it has somewhat limited applicability : since it has different formula according to the width of PGD and does not reflect various patterns of PGD which is caused by the decrease of soil stiffness, Therefore, in this study, the applicability of existing analytical relationship is closely investigated through the comparison of FEM results at first. And then, based on meaningful contemplation, improved analytical relationship is proposed. The proposed one models the system behavior of buried pipeline as the combination of cable and beam, and thus it is applicable to arbitrary width of PGD, Moreover, it does reflect various patterns of PGD by introducing interaction pattern coefficient. Through the comparison of numerical results using the FEM and the proposed analytical relationship, rational applicability is objectively verified and noticeable considerations are discussed, Moreover, analyses considering the change of PGD magnitude and patterns are performed.

EFFECTS OF PTERYGOMAXILLARY SEPARATION ON SKELETAL AND DENTAL CHANGES FOLLOWING SURGICALLY-ASSISTED RAPID MAXILLARY EXPANSION (외과적 급속상악확장술시 익돌상악 접합부의 분리 유무에 따른 치열궁 변화)

  • Han, In-Ho;An, Jin-Suk;Gu, Hong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.4
    • /
    • pp.320-328
    • /
    • 2006
  • Purpose: The aim of this study was to evaluate the effects of pterygomaxillary separation on dimensional changes of dental arch following surgically-assisted rapid maxillary expansion (SARME). Patients and Methods: Eighteen adults who had been treated by SARME for transverse maxillary deficiency from May 2000 to August 2005 were evaluated. Thirteen patients (Group 1) were treated with subtotal Le Fort I osteotomy including pterygomaxillary separation and anterior midpalatal osteotomy. The same operation was performed in five patients (Group 2) except pterygomaxillary separation. Dental study casts were taken before operation and after removal of expansion device. And then, skeletal and dental parameters were measured pre- and post-operatively. Results: 1. Changes of mean interdental width 1) In group 1, mean maxillary interdental width was increased 70%($47{\sim}99%$), 95%($84{\sim}115%$), and 77%($57{\sim}94%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 2) In group 2, mean maxillary interdental width was increased 77%($59{\sim}100%$), 78%($45{\sim}107%$), and 86%($57{\sim}116%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 3) There was a statistical difference between the change of interdental width of group 1 and group 2 at first premolar(p<0.05). 2. Changes of mean interalveolar width 1) In group 1, mean maxillary alveolar bone width was increased 66%($42{\sim}84%$), 74%($42{\sim}104%$), and 57%($31{\sim}78%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 2) In Group 2, mean maxillary alveolar bone width was increased 73%($55{\sim}98%$), 67%($36{\sim}89%$), and 59%($48{\sim}73%$) of total expansion on canine, first premolar, and first molar region, respectively after retention. 3) There were no statistical differences between group 1 and group 2 at each teeth area. Conclusion: These results suggest that SARME without pterygomaxillary separation may allow the relatively equal expansion at both anterior and posterior teeth area and most amounts of maxillary interdental expansions were acquired with the expansion of the maxilla by SARME.