• Title/Summary/Keyword: Transport condition

Search Result 977, Processing Time 0.024 seconds

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.4
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.

The Behavior of Leachate on The Transient Condition in The Nanji Waste Landfill (부정류 상태에서의 난지도 매립지 침출수 거동 예측)

  • 강동희;조원철;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.57-67
    • /
    • 2001
  • The purpose of this study is to predict appropriate leachate rates and leachate transport velocity through weathered zone and basement rock on the transient condition at Nanji waste landfill. The leachate transport in the Nanji waste landfill is analyzed using MODFLOW(A Modular 3-D Finite Different Groundwater Flow Model) model which simulates three dimension groundwater flow and MT3D(A Modular Three Dimentional Transport Model) model which describes three dimensional transport for advection, dispersion and chemical reaction of dissolved constituents in groundwater system on the transient condition. Leachate production rates are estimated by HELP(Hydraulical Evaluation of Landfill Performance) model and used weather records for recent 10 years. Leachate transport is predicted by a change of leachate level to after/before established HDPE, established slurry wall and wells.

  • PDF

RADIATION SAFETY ASSESSMENT FOR KN-12 SPENT NUCLEAR FUEL TRANSPORT CASK USING MONTE CARLO SIMULATION

  • Kim, J.K.;Kim, G.H.;Shin, C.H.;Choi, H.S.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.207-214
    • /
    • 2001
  • The KN-12 spent nuclear fuel (SNF) transport cask is designed for transportation of up to 12 assemblies and is in standby status for being licensed in accordance with Korea Atomic Energy Act. To evaluate radiation shielding and criticality safety of the KN-12 cask, each case of study was carried out using MCNP4B Code. MCNP code is verified by performing benchmark calculation for the KSC-4 SNF cask designed in 1989. As a result of radiation safety evaluation for the KN-12 cask, calculated dose rates always satisfied the standards at the cask surface, at 2m from the surface in normal transport condition, and at 1 m from the surface in hypothetical accident condition. Maximum dose rate was always arisen on the side of the cask. For normal transport condition, photons primarily contribute to dose rate between two kinds of released sources, neutrons and photons, from spent nuclear fuel but for hypothetical accident condition, contrary case was resulted. The level of calculated dose rate was 27.8% of the limit at the cask surface, 89.3% at 2 m from the cask surface, and 25.1% at 1 m from the cask surface. For criticality analysis, keff resulting from the criticality analysis considering the condition of optimum partial flooding with fresh water is 0.89708(0.00065. The results confirm the standards recommended by all regulations on radiation safety.

  • PDF

Structural integrity of KJRR-F fresh nuclear fuel under vehicle-induced vibration for normal transport condition

  • Jeong, Gil-Eon;Yang, Yun-Young;Bang, Kyoung-Sik
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1355-1362
    • /
    • 2022
  • Nuclear fuel, including its fresh state, must be handled safely due to its critical and hazardous nature. Under normal transport conditions, several interactions take place among different components, such as transport cask used for loading the nuclear fuel and tie-down structure to attach with the vehicle. To ensure structural integrity of the nuclear fuel, vibrations and impacts transmitted from the vehicle must be sufficiently reduced. Therefore, in this study, we conducted two transportation tests from Daejeon to Kijang in Korea to verify the vehicle-induced vibrational characteristics of the KJRR-F fresh nuclear fuel when transported under normal transport conditions. The speed and location of the vehicle were obtained via GPS, and the accelerations between the vehicle and the KJRR-F fresh nuclear fuel were measured. Additionally, using the acceleration results, a structural analysis was conducted to confirm the structural integrity of the nuclear fuel under the most severe conditions during normal transport.

Characteristics of East Asia Synoptic Meteorological Conditions in Association with Haze phenomena (연무와 연관된 동아시아의 종관기상 특성)

  • Jo, Hyun-Young;Kim, Cheol-Hee
    • Atmosphere
    • /
    • v.20 no.2
    • /
    • pp.161-172
    • /
    • 2010
  • In an effort to investigate the characteristics of synoptic meteorological conditions in association with long-range transport of haze phenomena occurred over Korea, we statistically classified characteristics of haze events into two types of haze: stagnant case and long-range transport case, based on the synoptic meteorological parameters, and analyze comparatively the characteristics of synoptic meteorological conditions for each case. The results showed that the occurrence frequency of stagnant case accounts for 64.5%, showing superiority of stagnant haze cases over the long-range transport case which occupies only 35.5% among total 67 cases for the period from 2000 to 2007. This result indicates that haze phenomena occurred over Korea has influenced by not only the emission in Korea by itself but long range transport effects originating from China inland. The synoptic condition on 850hPa level showed that, when stagnant case occurred, Korean peninsula was located under the effects of negative vorticity with the significantly weak wind speed and stable atmospheric condition. In contrast, long-range transport case shows positive vorticity and relatively strong wind speed over 850hPa level, especially with the location of high pressure system over the area of southwestern China. This location of high pressure system implies to induce the westerlies or northwesteries consistently due to its pressure gradient by itself. Also other comparative studies haze days (vs.) Asian dust days are carried out, and we found out that the patterns of long-range transport of haze phenomena in Korea shows similar to Asian dust case but the static stability condition indicates more stabilized atmospheric condition than dust phenomena.

A study on the exchange Kaesong area of goods transport train by the inter-Korean Railway Connection (남북철도 연결에 따른 개성지역 화물열차운행에 대한 연구)

  • Park Hong-Soon
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1671-1676
    • /
    • 2004
  • This thesis watches for the present condition of both economic exchange and goods transport between South and North Korea focused on material side as a provision for the railway connection between them. This is also a predicting thesis for a smooth goods transport in case of setting up a goods transport system between south and North Korea predicting transport demand for the connection of a railway and road studying fundamental facilities and transport related laws.

  • PDF

A study on the Exchange of goods transport freight by the Inter-Korean Railway Connection (남북철도 연결에 따른 화물운송에 대한 연구)

  • Park Hong-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.190-195
    • /
    • 2003
  • This thesis watches for the present condition of both economic exchange and goods transport between South and North Korea focused on material side as a provision for the railway connection between them. This is also a predicting thesis for a smooth goods transport in case of setting up a goords transport system between south and North Korea predicting transport demand for the connection of a railway and road studying fundamental facilities and transport related laws.

  • PDF

A Study on the Heat and Moisture Transport Properties of Vapor-Permeable Waterproof Finished Fabrics for Sports Wear (스포츠웨어용 투습방수직물의 열·수분이동 특성에 관한 연구)

  • Son, Bu Hun;Kim, Jin-A;Kwon, Oh Kyung
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.220-226
    • /
    • 2000
  • This study was to determine the characteristics of vapor-permeable waterproof finished fabric by the coating method. 4 different kinds of coating fabrics (A : wet, porous, polyurethane, B : dry, no porous, polyurethane, C : shape memory polyurethane and D : dry, porous polyurethane) were used, which were developed recently With this sample, moisture transport rate ($40^{\circ}C$, 45%RH & $40^{\circ}C$, 95%RH), changes of coating side's shape by washing times, water repellency rate, contracted length, qmax, heat conductivity, heat keeping rate, heat keeping rate with cotton, heat keeping rate on humidity temperature and humidity within clothing etc. were checked. And it was done in a climate chamber under $20{\pm}2^{\circ}C$, $65{\pm}5%RH$. The results of this study were as follow; In the moisture vapor transmission of sample B and C increased on high temperature and high humidity while sample A and D decreased, on this condition. Qmax rate had high relation with ground fabric's surface properties and the order was A>C>D>B. Heat conductivity had high relation with thickness and surface properties. Heat keeping rates on sweat condition showed around half percents of heat keeping rates on normal condition, but had no relation with moisture vapor transport rate. Changes of the fabric's properties by washing times were different in accordance with the construction of fabrics and the coating resin. Sample C had tow heat keeping rate on the high temperature and humidity and high heat keeping rate on the low temperature and humidity Moisture transport rate of vapor-permeable waterproof finished fabrics had high relation with the properties of ground fabrics on low humidity condition, but on the high humidity condition, it was highly related with the properties of coating resin.

  • PDF

Containment Evaluation of the KN-12 Transport Cask

  • Chung, Sung-Hwan;Choi, Byung-Il;Lee, Heung-Young;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.291-298
    • /
    • 2003
  • The KN-12 transport cask has been designed to transport 12 PWR spent nuclear fuel assemblies and to comply with the regulatory requirements for a Type B(U) package. The containment boundary of the cask is defined by a cask body, a cask lid, lid bolts with nuts, O-ring seals and a bolted closure lid. The containment vessel for the cask consists of a forged thick-walled carbon steel cylindrical body with an integrally-welded carbon steel bottom and is closed by a lid made of stainless steel, which is fastened to the cask body by lid bolts with nuts and sealed by double elastomer O-rings. In the cask lid an opening is closed by a plug with an O-ring seal and covered by the bolted closure lid sealed with an O-ring. The cask must maintain a radioactivity release rate of not more than the regulatory limit for normal transport conditions and for hypothetical accident conditions, as required by the related regulations. The containment requirements of the cask are satisfied by maintaining a maximum air reference leak rate of $2.7{\times}10^{-4}ref.cm^3s^{-1}$ or a helium leak rate of $3.3{\times}10^{-4}cm^3s^{-1}$ for normal transport conditions and for hypothetical accident conditions.

A Study on Fuel Transport Characteristics in a Port Fuel Injected Sl Engine during Transient Condition (흡기포트 분사방식의 가솔린 엔진에서 급가속시 연료 거동에 관한 연구)

  • 황승환;조용석;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.20-27
    • /
    • 2003
  • In this paper, the fuel transport characteristics during transient condition was studied by using a Fast Response Flame Ionization Detector(FRFID). The quantitative measurement method for the inducted fuel mass into cylinder is studied. The inducted fuel mass into the cylinder was estimated by using calculated air-fuel ratio by hydrocarbon concentration of cylinder and air flow model. In order to estimate the transportation of injected fuel from the intake port into cylinder, the wall wetting fuel model was used. The two coefficient $\alpha$,$\beta$) of the wall-wetting fuel model was determined from the measured fuel mass that was inducted into the cylinder at the first cycle after injection cut-off To reduce an air/fuel ratio fluctuation during rapid throttle opening, the appropriate fuel injection rate was obtain from the wall wetting model with empirical coefficients. Result of air/fuel ratio control, air/fuel excursion was reduced.