• Title/Summary/Keyword: Transmitted Vibration

Search Result 405, Processing Time 0.026 seconds

Assessment on Mechanical Performance of Porcelain and Glass Insulators by Pendulum Weight (진자 추에 의한 자기 및 유리애자의 기계적 성능 평가)

  • Shong, Kil-Mok;Kim, Jong-Min;Kim, Young-Seok;Bang, Sun-Bae;Kim, Sun-Gu;Jeon, Yong-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.475-476
    • /
    • 2008
  • This paper is an experimental test for the close examination of breakdown causes of glass insulators using at the electric rail-road. The glass insulator is estimated the mechanical performance according to hitting test(ST-100, Sharp-Eng, KOR) that is based on KSC 3810. Insulators is damaged by pendulum weight at the steps of hitting angles. Glass and porcelain insulators are broken at the hitting angle of $72^{\circ}$. From the these results, glass insulator absorbed the impact from the pendulum weight but on the porcelain insulator, it is not transmitted vibration by impact. Hereafter, these results are expected that is used the data for the assessment on breakdown cause of a glass insulator.

  • PDF

Modeling and Active Control of an Air-Cell Seat for Ride-Comfort Improvement (승차감 향상을 위한 에어셀시트의 모델링 및 능동제어)

  • Hong, Keum-Shik;Hwang, Su-Hwan;Hong, Kyung-Tae;Yoo, Wan-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1672-1684
    • /
    • 2004
  • In this paper, an active vibration control with the use of an air-cell seat for passenger cars is investigated. The roles of the air-cell inserted between the polyurethane foam of the seat and seat cover are first to extend the seat's capability to adopt various shapes of human body and to improve the ride-comfort against road disturbances. The air-cell seat is modeled as a 1-d.o.f. spring-damper system. Because an exact modeling of the air-cell itself is alomost impossible, its dynamic characteristics are analyzed through experiments. A road-adaptive gain-scheduled sky-hook control for the air-cell seat system is proposed. The skyhook gains are scheduled in such a way that the acceleration level transmitted to human body on various road conditions is minimized. Simulations and experimental results are provided.

A Study on the Empirical Modeling of Rubber Bushing for Dynamic Analysis (동역학 해석을 위한 고무부싱의 실험적 모델링에 대한 연구)

  • Sohn, Jeong-Hyun;Baek, Woon-Kyung;Kim, Dong-Jo
    • Elastomers and Composites
    • /
    • v.39 no.2
    • /
    • pp.121-130
    • /
    • 2004
  • A rubber bushing connects the components of the vehicle each other and reduce the vibration transmitted to the chassis frame. A rubber bushing has the nonlinear characteristics for both the amplitude and the frequency and represents the hysteretic responses under the periodic excitation. In this paper, one-axis durability test is performed to describe the mechanical behavior of typical vehicle elastomeric components. The results of the tests are used to develop m empirical bushing model with an artificial neural network. The back propagation algerian is used to obtain the weighting factor of the neural network. A numerical example is carried out to verify the developed bushing model and the vehicle simulation is performed to show the fidelity of proposed model.

Application of Mid-Story Isolation System for Reducing Seismic Response of Space Structure (공간구조물의 지진응답 저감을 위한 중간면진장치의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won;Kim, Hyung-Man
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.97-103
    • /
    • 2009
  • The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of arch structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.

  • PDF

Analysis and Isolation of Cultivator Vibration transmitted to Hand (손으로 전달된 관리기 진동의 분석과 방진 대책)

  • 박영준;채문권;김경욱
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.104-110
    • /
    • 2002
  • 본 연구는 보행형 관리기의 손으로 전달되는 진동특성을 실험적으로 해석하고 평가하며 방진 방안을 제시할 목적으로 수행되었다. 관리기의 작업기 중에서 설문을 통해 사용 빈도가 높은 3개의 작업기(중경로터리, 중경제초기, 구굴기)를 선정하였고 각 작업기별 진동수준을 측정하였다. 진동 방지 방안에 대해서는 4개의 방진 장치(고무 패드, 방진 장갑, 핸들 방진 장치, 엔진 마운트)를 선정하여 각 방진 장치별 진동수준을 측정하였다. 방진 장치의 성능을 정확하게 비교하기 위해 진동의 측정은 진동수준이 가장 높은 구굴기에서 수행되었다. 실험결과에 의하면 관리기 작업이 작업자의 인체에 해를 끼칠 위험이 매우 크지만 이 결과는 작업자가 매일 3시간씩 관리기를 사용할 경우를 기준으로 설정한 값이기 때문에 실제로 관리기 사용일수가 많지 알은 대부분의 우리나라 사용자들에게 적용하는데는 한계가 있음을 밝힌다. 그렇다 하더라도 관리기의 주 사용자는 보행형 관리기 뿐만 아니라 보행형 경운기나 보행형 이앙기 등의 손으로 전달되는 진동이 심한 기계를 함께 사용하는 경우가 많음을 고려하면 방진 장치를 개발하거나 진동수준이 낮은 농작업기계를 개발하여 작업환경을 개선하는 조치가 필요하다고 생각한다. 그러므로 농작업기계에 대한 진동수준에 대한 종합적인 연구와 그에 대한 대책 마련이 지속적으로 수행되어야 할 것이다.

  • PDF

Systematic test on the effectiveness of MEMS nano-sensing technology in monitoring heart rate of Wushu exercise

  • Shuo Guan
    • Advances in nano research
    • /
    • v.15 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • Exercise is beneficial to the body in some ways. It is vital for people who have heart problems to perform exercise according to their condition. This paper describes how an Android platform can provide early warnings of fatigue during wushu exercise using Photoplethysmography (PPG) signals. Using the data from a micro-electro-mechanical system (MEMS) gyroscope to detect heart rate, this study contributes an algorithm to determine a user's fatigue during wushu exercise. It sends vibration messages to the user's smartphone device when the heart rate exceeds the limit or is too fast during exercise. The heart rate monitoring system in the app records heart rate data in real-time while exercising. A simple pulse sensor and Android app can be used to monitor heart rate. This plug-in sensor measures heart rate based on photoplethysmography (PPG) signals during exercise. Pulse sensors can be easily inserted into the fingertip of the user. An embedded microcontroller detects the heart rate by connecting a pulse sensor transmitted via Bluetooth to the smartphone. In order to measure the impact of physical activity on heart rate, Wushu System tests are conducted using various factors, such as age, exercise speed, and duration. During testing, the Android app was found to detect heart rate with an accuracy of 95.3% and to warn the user when their heart rate rises to an abnormal level.

Snoring Detection using Polyvinylidene Fluoride Vibration Sensors (Polyvinylidene Fluoride 진동센서를 이용한 코골이 검출)

  • Jee, Duk-Keun;Wei, Ran;Kim, Hee-Sun;Im, Jae-Joong
    • Science of Emotion and Sensibility
    • /
    • v.14 no.3
    • /
    • pp.459-466
    • /
    • 2011
  • Sleep diseases such as snoring and sleep apnea are physically, mentally harmful and results serious health problems. Snoring, known as breathing noise, is caused by coupled oscillation of the airway when the air passes through the trachea, and sleep apnea is caused by upper airway blockage. In order to solve these problems, many attempts have been made to detect the snoring during sleep and alleviate it. In this study, a new sensing system and analysis algorithm were developed in order to detect snoring sounds correctly under various sleep environments. Two polyvinylidene fluoride (PVDF) vibration sensors were used inside the pillow. The first PVDF sensor detects vibration transmitted through skull caused by snoring. And the second PVDF sensor detects both snoring sounds and ambient noises. The signals of two sensors were acquired through the designed analog circuits, and analyzed for snoring detection. Ten volunteers were participated for the experiment under five different conditions. Data from two PVDF sensors were processed by the established analysis algorithm, and snoring sounds were compared to noises. The results indicated that the energy of snoring is 70% bigger than that of ambient noise, which proves effectiveness of sensing system and analysis algorithm. Further study would be continued for more wide clinical studies with various environment noises. Based on this study, development of anti-snore pillow and sleep monitoring system for comfort sleep could be developed.

  • PDF

Typical Seismic Intensity Calculation for Each Region Using Site Response Analysis (부지응답해석을 이용한 지역별 대표 진도 산출 연구)

  • Ahn, Jae-Kwang;Son, Su-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.1
    • /
    • pp.5-12
    • /
    • 2020
  • Vibration propagated from seismic sources has damping according to distance and amplification and reduction characteristic in different regions according to topography and geological structure. The vibration propagated from the seismic source to the bedrock is largely affected by the damping according to the separation distance, which can be simply estimated through the damping equation. However, it is important to grasp geological information by location because vibration estimation transmitted to the surface are affected by the natural period of the soil located above the bedrock. Geotechnical investigation data are needed to estimate the seismic intensity based on geological information. If there is no Vs profile, the standard penetration tests are mainly used to determine the soil parameters. The Integrated DB Center of National Geotechnical Information manages the geotechnical survey data performed on the domestic ground, and there is the standard penetration test information of 400,000 holes. In this study, the possibility of quantitation the amplification coefficient for each region was examined to calculated the physical interactive seismic intensity based on geotechnical information. At this time, the shear wave column diagram was generated from the SPT-N value and ground response analysis was performed in the target area. The site coefficients for each zone and the seismic intensity distribution for the seismic motion present a significant difference according to the analysis method and the regional setting.

Noise Cancellation Algorithm of Bone Conduction Speech Signal using Feature of Noise in Separated Band (밴드 별 잡음 특징을 이용한 골전도 음성신호의 잡음 제거 알고리즘)

  • Lee, Jina;Lee, Gihyoun;Na, Sung Dae;Seong, Ki Woong;Cho, Jin Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.128-137
    • /
    • 2016
  • In mobile communication, air conduction(AC) speech signal had been commonly used, but it was easily affected by ambient noise environment such as emergency, military action and rescue. To overcome the weakness of the AC speech signal, bone conduction(BC) speech signal have been used. The BC speech signal is transmitted through bone vibration, so it is affected less by the background noise. In this paper, we proposed noise cancellation algorithm of the BC speech signal using noise feature of decomposed bands. The proposed algorithm consist of three steps. First, the BC speech signal is divided into 17 bands using perceptual wavelet packet decomposition. Second, threshold is calculated by noise feature during short time of separated-band and compared to absolute average of the signal frame. Therefore, the speech and noise parts are detected. Last, the detected noise parts are removed and then, noise eliminated bands are re-synthesised. In order to confirm the efficiency of the proposed algorithm, we compared the proposed algorithm with conventional algorithm. And the proposed algorithm has better performance than the conventional algorithm.

Walking Assistance Device for Prevention of Accidents of Visually Impaired People (시각장애인의 사고예방을 위한 다기능 보행 보조 장치)

  • Sim, Jae-Man;Lee, Hyeong-Wook;Shin, Joo-Yong;Kim, Ki-Won;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1241-1248
    • /
    • 2019
  • In this paper, an auxiliary device was implemented to help blind people more safely from obstacles or risk factors while walking. The ultrasonic sensors detect obstacles in the front, so that the noise gap and the vibration intensity of the buzzer can be heard differently by distance and angle, and so the situation can be perceived by pedestrians. When the ambient light becomes darker than the light intensity set using the CdS resistance value of the light sensor, the LED automatically turns on, makes it easier for pedestrians to recognize the position of the auxiliary device through buzzer if the pedestrian misses the aid using the gyro sensor's slope. Moreover, the location and situation of the blind were transmitted to the caregiver to check safety and behavior using GPS and Bluetooth.