• Title/Summary/Keyword: Transmit-Receive coil

검색결과 9건 처리시간 0.022초

Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe

  • Lee, Hyang-Beom
    • 비파괴검사학회지
    • /
    • 제26권1호
    • /
    • pp.25-29
    • /
    • 2006
  • In this paper, the eddy current signals come from a pair oi transmit-receive (T/R) pancake coil on ECT array Probe are analyzed with the variations of the lift-of and of the distance between transmit and receive coils. To obtain the electromagnetic characteristics of the probes, the governing equation describing the eddy current problems is derived from Maxwell's equation and is solved using three-dimensional finite element method. Eddy current signals from T/R coils on ECT array probe have quite different characteristics compared with ones from impedance coil on rotating pancake coil probe. The results in this paper ran be helpful when the field eddy current signals from ECT array probe are evaluated.

T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석 (Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP)

  • 임건규;이향범
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.159-165
    • /
    • 2008
  • 본 논문에서는 전자기 유한요소 해석을 통하여 배열와전류프로브의 T/R 코일의 와전류탐상 특성을 해석하였다. 신호해석을 위해 사용된 결함은 Notch 결함이며, 결함의 깊이는 관두께를 기준으로 40[%]로 하였으며, 결함의 위치는 관의 내부 및 외부에 있는 것으로 하였다. Transmit 코일을 중심으로 Receive 코일의 위치를 원주방향으로 $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$에 위치시키면서 신호해석을 수행하였다. 프로브의 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 이를 3차원 유한요소법을 이용하여 수치 해석을 수행하였다. 두 종류 결함의 수치해석 비교 결과 내부결함의 신호가 외부결함보다 크게 발생하였고, Transmit 코일에 대한 Receive 코일의 각도 및 위치 변화시 결함신호의 차이를 확인할 수 있었다. ASME 표준 시험편을 이용한 배열와전류 프로브의 와전류탐상 실험신호와 비교결과 유사한 신호를 확인할 수 있었다. 본 논문의 결과는 배열와전류 프로브의 와전류 탐상 신호 평가시 도움이 될 것이다.

송수신 모드 배열 코일 와전류 탐촉자의 특성 연구 및 이를 이용한 표면검사 (Study on Characteristics of Eddy Current Array Coil Operated in Transmit-Receive Mode and Surface Inspection Using This Probe)

  • 이태훈;지동현;조찬희;김인철
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.21-28
    • /
    • 2017
  • 배열 와전류 기술은 2차원적으로 나란히 정열된 다수의 와전류 코일로 구성된 탐촉자 면적에 대하여 기계적인 이동없이 전기적으로 주사할 수 있다. 단일 코일을 사용하는 와전류 기술과 비교하여 탐촉자가 한 번의 이동으로 넓은 영역을 검사할 뿐만 아니라 데이터 해석이 용이하여 검사 속도와 신뢰성을 향상시키는 장점이 있다. 이번 연구에서는 $2{\times}16$ 코일 배열의 배열 와전류 탐촉자와 순차적으로 송수신 코일을 선택하고 송수신 모드로 동작시키는 다중화기기를 개발하였다. 이 탐촉자를 이용하여 다양한 종류의 시편을 제작하여 표면검사를 수행하고, 와전류 신호 및 C-scan을 이미지 분석을 통해 송수신 모드 배열 와전류 기술의 특성에 대해 연구하였다.

와전류탐상 T/R 프로브 제작을 위한 센서의 임피던스 특성해석 (Impedance Characteristics Analysis of Eddy Current Testing Sensor for T/R Probe Design)

  • 김지호;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.566-569
    • /
    • 2008
  • 와전류탐상(ECT) Transmit-Receive 프로브를 이용한 ECT 방법은 센서코일의 유도기전력의 변화를 관찰하여 피검사체의 결함이나 특성의 변화를 탐지해내는 방법이다. ECT T/R 프로브는 여러 개의 Pancake 코일로 구성되어있고, 각각의 코일은 Transmit 코일과 Receive 코일로 나뉜다. 본 논문은 실제 TH 프로브 제작에 앞서 동일한 특성을 갖는 와전류센서를 설계 및 제작하여 그 특성을 파악하였다. 와전류센서에 인가되는 시험주파수와 Lift-off의 변화에 대한 특성을 파악하고 와전류센서의 임피던스값을 산출하여 정규화 임피던스도를 그려 와전류센서의 특성을 살펴보았다.

  • PDF

Development of Quadrature Detection Surface Coil: for Functional Magnetic Resonance Imaging at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.77-77
    • /
    • 2002
  • 목적: We has proposed a surface coil which has improved SNR compared with the standard head coil. Usually, a cylindrical head coil provide good homogeneity but less SNR than surface coil. A surface coil has better SNR at the expense of image homogeneity. In this paper, a surface coil of transmit-receive mode offers a better SNR as compared with a head coil.

  • PDF

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

자기변형 트랜스듀서를 이용한 평판구조물의 특정방향 가진 및 측정 (The Actuation and Measurement of plate Structures at a Specific Direction by a Magnetostrictive Transducer)

  • 이주승;조승현;선경호;김윤영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.153-158
    • /
    • 2004
  • The coupling phenomenon between stress and magnetic induction, known as magnetostriction, has been successfully applied to generate and measure elastic waves. Most applications of this phenomenon thus far, however, are rather limited to cylindrical ferromagnetic waveguides. The main objective of this work is to develop a new patch-type, orientation-adjustable magnetostrictive transducer that is applicable for non-cylindrical, non-ferromagnetic waveguides. The existing patch-type transducer consisting of a ferromagnetic patch and a racetrack coil is useful to generate elastic waves only in one specific direction once the patch is bonded to a test specimen. However, the proposed transducer can transmit and receive elastic waves in any direction only with one patch at a given location. The proposed magnetostrictive transducer consists of a circular nickel patch, a figure-of-eight coil, and a couple of bias permanent magnets. Because of the unique configuration of the transducer, the propagating direction of the generated waves can be freely controlled since the set of bias magnets and the coil is not bonded to the magnetostrictive patch. In this work, the characteristics of the proposed transducer were investigated experimentally.

  • PDF

웨이브렛 변환과 SH-EMAT을 이용한 배관 용접부 결함 검출 (Flaw Detection in Pipe-Welded Zone by Using Wavelet Transform and SH-EMAT)

  • 이진혁;김대현
    • 대한기계학회논문집A
    • /
    • 제36권12호
    • /
    • pp.1511-1519
    • /
    • 2012
  • 배관설비는 용접이음으로 많은 부분이 구성되어 있으며, 이러한 배관 용접부의 건전성 평가를 위한 초음파 검사 시스템의 자동화 요구가 증대하고 있다. 전자기초음파탐촉자(Electromagnetic Acoustic Transducer; EMAT)는 비접촉 방식으로 초음파를 송 수신할 수 있고 다양한 초음파 모드의 발생이 가능하여 초음파 자동화 시스템 구축에 매우 유용하다. 본 연구에서는 수평횡파(Shear Horizontal wave; SH-wave) EMAT를 적용하여 배관의 용접부에 존재하는 결함의 검출을 수행하였다. 이때 수평횡파의 특정 모드($SH_0$)의 신호해석을 위해 웨이브렛 변환(Wavelet Transform)을 이용한 신호의 시간-주파수 분석을 수행 하였다. 웨이브렛 변환으로 해석된 SH0 모드 주파수의 반사 신호강도가 결함의 길이와 선형적 관계를 나타내어 효과적으로 용접부 결함 검출이 가능하였다.

뇌척수액 미세순환을 통한 래트 내이 외림프의 가돌리늄 조영제 증강 특성 (Enhancement Characteristics of Gadolinium Contrast Agent in the Rat Inner Ear Perilymph through CSF microcirculation)

  • 김민정;이상열;이희중;이태관;장용민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.193-198
    • /
    • 2022
  • Contrast enhanced magnetic resonance imaging using gadolinium-based contrast agent (GBCA) is a very useful in vivo technique to visualize the inner ear pathology including endolymphatic hydrops. Although systemic intravenous (IV) administration can visualize the perilymph space, the visualization was possible by indirect passage of contrast agent through blood-perilymph barrier. All animal experimental procedures were performed under anesthesia with 5% isoflurane. Lipopolysaccharide (LPS) was instilled into the left tympanic cavity through the tympanic membrane using a sterile 27gauge needle to induce hydrops model. Tucker-Davis Technologies system was used to measure Auditory Brainstem Responses (ABRs). For intracerebroven-tricular (ICV) administration, 25 µmol of GADOVIST (Bayer, Berlin, Germany) was used and diluted GADOVIST injection was 10 µl. MR imaging was acquired with a 9.4 Tesla MRI scanner. Transmit-receive volume coil with 40 mm inner diameter and 75 mm out diameter was used. ICV administration well demonstrated the strong enhancement along the cerebrospinal fluid (CSF) microcirculation pathway including CSF fluid in the subarachnoid space and CSF space of the inner ear structures. On the other hand, IV administration showed no contrast enhancement along the CSF microcirculation pathway and showed weak enhancement in the inner ear structures. In case of rat hydrops model, ICV administration showed that the reduced contrast enhancement in the perilymph space of the hydrops induced inner ear compared to the contrast enhancement in the perilymph space of the normal inner ear. New systemic ICV administration method provide contrast enhancement of GBCA in the inner ear through CSF microcirculation pathway.