• Title/Summary/Keyword: Transmission of Data

Search Result 6,329, Processing Time 0.029 seconds

An Efficient Scheme to write a Transmission Schedule using Convergence after Interactive Operations in a Stored Video (대화형 연산 후 수렴을 이용한 저장된 비디오의 효율적인 전송 스케줄 작성 방안)

  • Lee, Jae-Hong;Kim, Seung-Hwan
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.7
    • /
    • pp.2050-2059
    • /
    • 2000
  • In a video-on-Demand(VOD) service, a server has to return to he normal playback quickly at a certain new frame position after interactive operations such as jump or last playback. In this paper, we propose an efficient scheme to write a transmission schedule for a playback restart of a video stream at a new frame position after interactive operations. The proposed scheme is based on convergence characteristics, that is transmission schedules with different playback startup frame position in a video stream meet each other at some frame position. The scheme applies a bandwidth smoothing from a new frame position to a convergence position without considering all remaining frames of a video stream. And then the scheme transmits video dta according to the new schedule from the new frame position to the convergence position, and then transmits the remaining video data according to the reference schedule from the convergence position, and then transmits the remaining video data according to the reference schedule from the convergence position to the last frame position. In this paper, we showed that there existed the convergence position corresponding to nay frame position in a video stream through many experiments based on MPEG-1 bit trace data. With the convergence we reduced the computational overhead of a bandwidth smoothing, which was applied to find a new transmission schedule after interactive operations. Also, storage overhead is greatly reduced by storing pre-calculated schedule information up to the convergence position for each I frame position of a video stream with video data off-line. By saving information on a transmission schedule off-line along with the video data and searching the schedule corresponding to the specified restarting frame position, we expect the possibility of normal playback of a video stream with small tolerable playback startup delay.

  • PDF

Smart meter data transmission device and power IT system using LTE and IoT technologies (LTE와 IoT 기술을 이용한 스마트미터 데이터 전송장치와 전력 IT 시스템)

  • Kang, Ki-Beom;Kim, Hong-Su;Jwa, Jeong-Woo;Kim, Ho-Chan;Kang, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.117-124
    • /
    • 2017
  • A Smart Grid is a system that can efficiently use energy by exchanging real-time information in both directions between a consumer and a power supplier using ICT technology on an existing power network. DR(Demand response) is an arrangement in which electricity users can sell the electricity they save to the electricity market when the price of electricity is high or the power system is crisis. In this study, we developed a power meter data transmission device and power IT system that measure the demand information in real-time using a smart meter and transmit it to a cloud server. The power meter data transmission device developed in this study uses alight sensor connected to a Raspberry Pi 3 to measure the number of blinking lamps on the KEPCO meter per unit of power, in order to provide reliable data without any measurement errors with respect to the KEPCO power data. The power measurement data transmission device uses the standard communication protocol, OpenADR 2.0b. The measured data is transmitted to the power IT system, which consists of the VEN, VTN, and calculation program, via the LTE WiFi communication network and stored in its MySQL DB. The developed power measurement data transmission device issues a power supply instruction and performs a peak reduction DR when a power system crisis occurs. The developed power meter data transmission device has the advantage of allowing the user to adjust it every 1 minute, where as the existing smart metering time is fixed at once every 15 minutes.

A Study on the Noise Reduction Method for Data Transmission of VLBI Data Processing System (VLBI 자료처리 시스템의 데이터 전송에서 잡음방지에 관한 연구)

  • Son, Do-Sun;Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Jung, Jin-Seung;Oh, Chung-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.333-340
    • /
    • 2011
  • KJJVC(Korea-Japan Joint VLBI Correlator) was installed at the KJCC(Korea-Japan Correlation Center) and has been operated by KASI(Korea Astronomy and Space Science Institute) from 2009. KJNC is able to correlate the VLBI observed data through KVN(Korean VLBI Network), VERA(VLBI Exploration of Radio Astrometry), and JVN(Japanese VLBI Network) and its joint network array. And it is used exclusively as computer in order to process the observed data for the scientific purpose KJJVC used the VSI(VLBI Standard Interface) as the VLBI international standard at the data input-output specification between each component. Especially, for correlating the observed data, the data is transmitted with 1024Mbps speed between Mark5B high-speed playback and RVDB(Raw VLBI Data Buffer). The EMI(Electromagnetic lnterference), which is occurred by data transmission with high-speed, cause the data loss and the loss occurrence is frequently often for long transmission cable. Finally it will be caused the data recognition error by decreasing the voltage level of digital data signal. In this paper, in order to minimize the data loss by measuring the EMI noise level in transmission of the VSI specification, the 3 methods such as 1) RC filtering method, 2) lmpedance matching using Microstrip line, and 3) Signal buffering method using Differential line driver, were proposed. To verify the effectiveness of each proposed method, the performance evaluation was conducted by implementing and simulations for each method. Each proposed method was effectively confirmed as the high-speed data transmission of the VSI specification.

Data Aggregation and Transmission Mechanism for Energy Adaptive Node in Wireless Sensor Networks (무선 센서네트워크 환경에서 에너지를 고려한 노드 적응적 데이터 병합 및 전달 기법)

  • Cho, Young-Bok;You, Mi-Kyung;Lee, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11A
    • /
    • pp.903-911
    • /
    • 2011
  • In this paper we proposed an energy adaptive data aggregation and transmission mechanism to solve the problem of energy limitation in wireless sensor networks (WSNs). Hierarchical structure methods are wildly used in WSNs to improve the energy efficiency. LEACH and TEEN protocols are the typical techniques. In these methods, all nodes, including nodes who have sensed data to transmit and nodes who haven't, are set frame timeslots in every round. MNs (member nodes) without sensed data keep active all the time, too. These strategies caused energy waste. Furthermore, if data collection in MNs is same to the previous transmission, it increases energy consumption. Most hierarchical structure protocols are developed based on LEACH. To solve the above problems, this paper proposed a method in which only MNs with sensed data can obtain allocated frame to transmit data. Moreover, if the MNs have same sensed data with previous, MNs turn to sleep mode. By this way redundant data transmission is avoided and aggregation in CH is lightened, too.

A Study on the Implementation of Signal Transmission System Within Electric Culvert (지하 전력 구내에서 신호 전송 시스템의 실현에 관한 연구)

  • 진달복;오상기;최성주;나채동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.3
    • /
    • pp.49-56
    • /
    • 1993
  • This paper describes design and implementation of signal transmission system using LCX as communication media, which has characteristics of high reliability easy for expansion and complex transmission of voice, data and video signal in Electric culvert. In this system, we estimated system performance as result of variable transmission characteristics test. In case of voice signal, transmission loss characteristics improved 5-10(dB] than designed Values in received signal level. In the test of speech quality estimation, we obtained satisfactory result as speech intensity = 3 (QSA value), speech atriculation = 4 (QRK value). As for data and video signal transmission, communication success rates were 981% 1 in monitoring and control functional test. As a result of transmission characteristics test in transmission line and system, transmission range by LCX communication system without repeater can reach in 6Km. This paper presents basic construction method using LCX communication system for total management in Electric culvert.

  • PDF

Clinical implications of coronavirus disease 2019 in neonates

  • Kim, Do-Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.64 no.4
    • /
    • pp.157-164
    • /
    • 2021
  • Since the emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in December 2019, a small number of coronavirus disease 2019 (COVID-19) cases in neonates have been reported worldwide. Neonates currently account for only a minor proportion of the pediatric population affected by COVID-19. Thus, data on the epidemiological and clinical features of COVID-19 in neonates are limited. Approximately 3% of neonates born to mothers with COVID-19 reportedly tested positive for SARS-CoV-2. Current limited data on neonates with COVID-19 suggest that neonatal COVID-19 shows a relatively benign course despite a high requirement for mechanical ventilation. However, neonates with pre-existing medical conditions and preterm infants appear to be at a higher risk of developing severe COVID-19. The greatest perinatal concern of the COVID-19 pandemic is the possibility of vertical transmission, especially transplacental transmission of SARS-CoV-2. Although direct evidence of the vertical transmission of SARS-CoV-2 is lacking, its possibility during late pregnancy cannot be ruled out. This review summarizes available case studies on COVID-19 in neonates and introduces what is currently known about neonatal COVID-19 with focus on its vertical transmission.

A Study on the Optimism Design of the Gear Tooth Profile (치형수정에 의한 기어의 최적설계에 관한 연구)

  • Son, Yu-Sun;Hwang, Gue-Sec;Tak, Seong-Hun;Lyu, Sung-Ki
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.712-717
    • /
    • 2007
  • This study deals with the TE(Transmission Error) of gear tooth profile by modifying a profile and lead of a surface of tooth. First, we experimentally confirmed that the TE is a synthesis of the sliding velocity between both gears. Since various types of TE appear in the experiments, we introduced definition of transmission error and the optimism design by modifying a surface parameters. The test stand's performance is then evaluated through a series of multiple torque transmission error tests. Comparisons are made between data recorded before and after the test stand's redesign, and subsequently repeatability studies are performed to verify the veracity of the measured data. Finally, the experimental results are compared to the analytical predictions of two different gear analysis programs.

  • PDF

Analysis on Characteristics of Transmission Loss using Marginal Loss Factors Based on the KEPCO's Expected Peak Load Data of Year 2000 (한계손실계수에 의한 한전 예상첨두계통 송전손실 특성 분석)

  • NamKung, Jae-Yong;Choe, Heung-Gwan;Mun, Yeong-Hwan;O, Tae-Gyu;Im, Seong-Hwang;Han, Yong-Hui
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.7
    • /
    • pp.333-339
    • /
    • 2001
  • The transmission networks are not perfect conductors and a percentage of the power generated is therefore lost before it reaches the loads. This network loss effects to the cost of suppling power to consumers, and must be considered if the most efficient dispatch and location of generators and loads is to be achieved. In this paper, we propose an approximate calculation of marginal loss factors to analyze characteristics of transmission loss of KEPCO power system. These static marginal loss factors are approximately calculated based on the KEPCO's expected summer peak load data of year 2000.

  • PDF

Application of Principal Components Analysis Method to Wireless Sensor Network Based Structural Monitoring Systems

  • Congyi, Zhang;Mission, Jose Leo;Kim, Sung-Ho;Youk, Yui-Su;Kim, Hyeong-Joo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.8 no.1
    • /
    • pp.11-17
    • /
    • 2008
  • Typical wireless sensor networks used in structural monitoring are continuous types wherein data transmission is progressive at all time that may include irrelevant and insignificant data and information. Continuous types of wireless monitoring systems often pose problems of handling large-sized data that may deteriorate the performance of the system. The proposed method is to suggest an event-triggered monitoring system that captures and transmits relevant data only. An error signal generated by the Principal Components Analysis (PCA) is utilized as an index for event detection and selective data transmission. With this new monitoring scheme, the remote server is relieved of unwanted data by receiving only relevant information from the wireless sensor networks. The performance of the proposed scheme was verified with simulation studies.

The Data Compression Method for increase of Efficiency in Tactical Data Communication over Legacy Radios (Legacy Radio 기반의 전술데이터 통신 효율성 향상 위한 데이터 압축 기법)

  • Sim, Dong-Sub;Shin, Ung-Hee;Kim, Ki-Hyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.577-585
    • /
    • 2010
  • The Military Tactical Communication technology for effective network-centric warfare is developing. Targeting broadband wireless transmission, core technology for connection, and Transmission technology that secure survivability under High-speed Movement environment. On the one hand, Tactical data communication system that reflects military characteristic is developing on the base of Legacy communication equipment which is used in the field. Because almost every military units in the field have used voice to communicate which lower efficiency of operation, they have made effort to Substitute voice communication which delays military Operation Tempo to digital communication. The Communications environment of troops in Forward edge of battle field area is very poor. Especially in terms of limited frequency allocation and bandwidth. Therefore, improving the efficiency of frequency is essential for Military Tactical Communication. This paper is about The Data Compression Method for increase of Efficiency in Tactical Data Communication over Legacy Radios which are UHF, VHF, HF Radio. I proposed and proved the most efficient Data Compression Method that reflects military characteristic, after analyzing the experimentation, which simulate CAS(Close Air Support mission) data transmission between Pilot and TACP.