회전보상기를 이용한 분광타원기술에 있어서의 캘리브레이션 (Calibrations in rotating compensator spectroscopic ellipsometry)

  • An, Ilsin
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.256-259
    • /
    • 2001
  • Rotating-compensator type ellipsometer was developed for spectroscopic measurements. For accurate data reduction, the azimuths of transmission axises of polarizer and analyzer, and the angular position of the fast axis of compensator should be determined through calibration process. In this paper, we present various calibration methods.

  • PDF

EXPERIMENTAL STUDIES ON SOME VIBRATION ISOLATIORS DEVELOPED FOR POWERED KNAPSACK SPRAYER

  • Sahota, M.S.;Bansal, A.S.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.246-255
    • /
    • 1993
  • The paper presents the experimental studies on the effectiveness of some vibration isolators developed for reducing transmission of vibration from the powered knapsack sprayer to the back and shoulders of the operator. A test rig was used to conduct detailed experimental studies on the powered knapsack sprayer mounted on it and fitted with different vibration isolators. Structural features of vibration isolators have been presented and their effectiveness of isolating transmission of vibration, from the engine-blower of the sprayer to its main frame and the operator, has been presented and discussed. Vibration measurements and analyses made by using B & K equipment have proved that the vibration isolators are quite effective in reducing the vibration transmission. The operators felt much less discomfort when they used the sprayer fitted with the isolators developed for the purposes, as compared to the existing arrangement.

  • PDF

Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정 (A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD)

  • ;조기연;변영복;서정일;김은수;김태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

Data Transmission over Power Line with Lightning Protection Devices

  • Kim, Sungeon;Jeon, Taehyun
    • International journal of advanced smart convergence
    • /
    • 제2권1호
    • /
    • pp.27-29
    • /
    • 2013
  • This paper discusses comparative analysis of the effects of surge protection devices (SPD) upon the power line communication channels. The quality of the data transmission channel is measured based on the data rate for the various channel parameters which include channel length and application method of the lightning protection device. The performance measurements are also carried out for various lengths of the communication channel. Experiment results show that specific combination of SPDs applied in the network causes severe degradation of the channel quality which is associated with the combination of grade levels and channel lengths.

초고압 송전선로의 자계크기 실측과 해석 (Measurement and Analysis of the Magnetic Fields Magnitude under High Voltage Transmission Lines)

  • 조성배;이은웅;이민명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1583-1585
    • /
    • 1998
  • EMF measurements for the selected lines by a kinds of tower configurations conductors among 154kV, 345kV transmission lines which are a standard forms of high voltage transmission line in Domestic are performed at the field. Based on these measurings, Co-relation of both the Power current and the magnetic field strength is studed. compared of measured and calculated magnetic magnitude. and Using the measured equation obtained from field measuring, Magnetic field exposure value occurring under T/L for one year(1997) is presented.

  • PDF

폴리머 마이크로 칩에 대한 레이저 투과 마이크로 접합 (Analysis of Transmission Infrared Laser Bonding for Micro Polymer Devices)

  • 김주한;신기훈
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.43-45
    • /
    • 2005
  • A precise bonding technique, transmission laser bonding using energy transfer, for polymer micro devices is presented. The irradiated IR laser beam passes through the transparent part and absorbed on the opaque part. The absorbed energy is converted to heat and bonding takes place. In order to optimize the bonding quality, the temperature profile on the interface must be obtained. Using optical measurements of the both plates, the absorbed energy can be calculated and heat transfer model was applied for obtaining the transient temperature profile. The transmission laser bonding has a potential in the local precise bonding in MEMS or Lab-on-a-chip.

  • PDF

Wireless Power Transmission between Two Metamaterial-Inspired Loops at 300 MHz

  • Kim, Gun-Young;Jung, Youn-Kwon;Lee, Bom-Son
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.219-223
    • /
    • 2010
  • Based on a provided closed-form wireless power transmission (WPT) efficiency formula, which may be used for any value of load, we have analyzed the WPT efficiencies between two metamaterial-inspired loop antennas in various aspects. Due to the modeling based on low frequency circuit theory, the provided formula at the center resonant frequency has been found to be accurate until when the distance between the two loop antennas increases to 15 cm (about $\lambda_0/6$ at 300 MHz). When the two loops get closer, the resonant frequency has been found to split into two in theory, simulations, and measurements. The EM-simulated and measured efficiencies at new resonant frequencies are 60.9 % and 46.3 %, respectively, at d=15 cm. With two extra rings around the loops, the maximum efficiency is enhanced to 93.7 % at d=15 cm. The effect of the additional two rings is about 30 %.

A Novel Compact Metamaterial Zeroth Order Resonant Bandpass Filter for a VHF Band and Its Stopband Improvement by Transmission Zeros

  • Kahng, Sungtek;Jang, Geonho
    • Journal of electromagnetic engineering and science
    • /
    • 제13권4호
    • /
    • pp.263-266
    • /
    • 2013
  • A novel compact and low-loss VHF bandpass filter is presented with enhanced stopband performance using metamaterial zeroth order resonator (ZOR) characteristics. An in-line ZOR filter is initially suggested and changed to have transmission zeros (TZs) due to source-load coupling for effective improvement of the isolation from UHF wireless channels. The proposed filter is smaller than 1/10 of the conventional filters in terms of size and has relatively very low insertion loss (< 1 dB for the electromagnetic (EM) simulation and < 3 dB for the measurement) and return loss (<-20 dB) in the passband due to the approximately 80% size reduction and the higher isolation in the stopband due to the TZs. The circuit and EM simulation are in good agreement with the measurements.

경량전철용 직류배전반의 정보 전송방식 (An Information Transmission Method of the DC Switchgear for Light Railway Vehicle)

  • 이현두;김수남;류승표;이세현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

Probability of exceeding the serviceability limit of antenna masts

  • Kammel, Christian
    • Wind and Structures
    • /
    • 제4권4호
    • /
    • pp.353-366
    • /
    • 2001
  • With respect to serviceability, antenna masts should be designed so that wind-induced motion will not cause unacceptable lack of transmission for broadcasting users and wireless communication. For such antenna masts with directional radio transmission the serviceability limit state is predominantly governed by the tolerable change of the broadcasting angle of the mounted antenna assembly and therefore by the tip distortion of the mast. In this paper it will be shown that refinements of the present state of design of antenna masts are possible by using the statistics of extremes applied to extreme wind situations and by consideration of the statistical and reliability requirements given by the operator such as frequency and return period of passing the serviceability limit.