Grounding System Design According to Indoor Substation (변전소 옥내화에 따른 접지설계)

  • Choi, J.K.;Joo, B.S.;Kim, M.D.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.905-907
    • /
    • 1996
  • Current design standard of substation grounding systems is primarily concerned with conventional outdoor substations. But in case of 154kV substations in the nation, almost all are indoor-type GIS substations. So there became to be something not proper for application of present design standard to indoor-type substations. In this paper, as a preliminary stage of drawing-up of the grounding system design standard which concerned with in-door-type substions, issues of current design standard are mentioned and directions of improvement are also presented.

  • PDF

Spacer Damper Design for Bundled Conductor Transmission Lines (다도체 송전선로용 스페이서댐퍼 설계)

  • Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1235-1237
    • /
    • 1998
  • Spacer Dampers must be carefully designed and tested. Because it can protect conductors from conductor oscillations due to winds and electrical forces. If the spacer damper has any problems in itself, it may cause extensive damage to the transmission lines. This paper suggests a design method and considerations of spacer damper for bundled conductor transmission lines.

  • PDF

Conceptual Design and Application of HTS Power Transmission Cable (고온초전도 전력케이블 설계 및 계통적용)

  • 조전욱;성기철;김해종;이언용;류강식;박종수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.129-133
    • /
    • 1999
  • In recent years, there is a growing needs for large capacity underground power transmission lines with the increasing demand of electric power in the urban area, where various environmental limitations are imposed on the overhead transmission lines. But it is difficult to get the space for the underground power transmission cables because of complicated distributions of underground public facilties such as subway, water pipes, gas etc. As the superconducting power cables have the large power transmission capacity, the high power transmission capacity, the high power transmission density, and low loss characteristics in comparison with a conventional cable, it would be a solution to meet the increased power demand. In this paper, the results of the conceptual design and analysis of power system of HTS power transmission cable is described.

  • PDF

Seismic Performance Evaluation and a Comparative Study on the Design Wind and Earthquake Loads for Power Transmission Towers (송전철탑의 내진성능평가 및 설계 풍하중과 지진하중의 비교 연구)

  • Hwang, Kyeong-min;Chun, Nak-hyun;Jang, Jung-bum;Yun, Kwan-hee;Kim, Tae-kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • In this study 24 power transmission towers were selected by considering various variables such as power transmission capacity, height and structural type to evaluate their seismic performance using the standard design response spectrum recently announced by the government. In addition, the stresses and sectional forces generated by the current design wind loads and revised seismic ones were compared to review the effects on the design of power transmission towers when the government-required seismic standards were raised. The results of seismic performance evaluation for the target power transmission towers showed that they had seismic capacity of 0.31~0.91g, and that they met the level of the earthquake-resistant special grade, which is the 2,400-year earthquake return periods and secured seismic safety. Further, the sectional forces caused by earthquakes in the towers were 33~82.5% of the ones due to wind loads, and it was also confirmed that the design wind loads were more dominant than design earthquake ones under the elevated seismic standards.

A New Design Approach for Asymmetric Coupled-Section Marchand Balun

  • Park, Ji An;Cho, Choon Sik;Lee, Jae Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.54-60
    • /
    • 2014
  • A systematic design for asymmetric coupled-section Marchand baluns is presented. Asymmetrically coupled transmission lines in multilayer configuration are exploited for constructing Marchand baluns. Design equations for characteristic impedance and electrical length of asymmetrical coupled transmission lines are derived for establishing a systematic design procedure. Novel Marchand balun based on these design equations is composed of two identical asymmetrical coupled transmission lines. However, contrary to the general conventional design approach where ranges for characteristic impedances of coupled lines are ambiguously capitalized, values for characteristic impedance and length are explicitly expressed. Our approach is fundamentally different from the design method using coupling coefficients where solution for coupling coefficient is inherently restricted. To verify the proposed method, one design example is performed for wideband Marchand balun in multilayer configuration, and is fabricated for verifying the design procedure proposed. Maintaining the return loss more than 10 dB, the bandwidth is measured from 0.43 to 1.0 GHz, where $S_{21}$ and $S_{31}$ show better than -4 dB. The measured phase and amplitude imbalances illustrate 0.5 dB and ${\pm}5^{\circ}$, respectively.

Measurement of Sound Transmission Loss in a Sound Barrier Filled with the Rice-Straw Particles by the Transfer Function and Laboratory Measurement Methods

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sang-Sik;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.4
    • /
    • pp.338-345
    • /
    • 2018
  • The sound insulation capacity of a barrier is indicated by its transmission loss. In this study, the sound transmission loss of a sound barrier filled with rice-straw particles was measured by the transfer function method and a laboratory measurement method. The results of the two measurements were compared. The transmission losses measured by the two methods were similar above a frequency of 500 Hz. The loss increased greatly upon the introduction of a plywood to the sound barrier. The results of this study are expected to be used to design sound barriers for roads.

Design and implementation of dual-mode narrow-band waveguide channel filter using measured iris transmission loss data (Iris 전송손실 측정값을 이용한 이중모드 협대역 도파관 채널여파기의 설계 및 제작)

  • 정근욱;이재현
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.19-28
    • /
    • 1995
  • In this paper, measured iris transmission loss data and simulated data by using 3-dimension full-wave analysis S/W are presented and compared with Marcuvitz's theory. And by using measured iris data, dual-mode narrow-band channel filters can be successfully implemented. This paper shows that there is severe difference between the transmission loss of iris calculated by using Marcuvitz's equation to calculate iris dimension, if the length of slot iris is longer than .lambda./.pi., and in the long urn the response of channel filter is distorted. Experimental result shows that the characteristic response of implemented channel filter by using the iris transmission loss graph presented here matches well the design specfications. In conclusion, iris transmission loss measurement method will be very useful to design channel filter.

  • PDF

An Inner-spherical Continuously Variable Transmission for Electric Bicycles

  • Park, Moon-Woo;Lee, Hyoung-Woo;Park, No-Gill
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • A new continuously variable transmission (CVT) for electric bicycles was developed using a traction drive mechanism with inner and outer spherical rotors. This electric bicycle CVT permits three propulsion modes: human-power only, motor-power only, or a combination of motor power and human power. In addition, the electric bicycle CVT has high power efficiency, large torque capacity, improved drivability, and good packageability. A prototype was manufactured based on a conceptual design, a performance analysis, and a detailed design. This prototype has a rated power of 250 W and input motor speed of 20 rad/s for an overall speed ratio in the range 0.3-1.2. A bench test was conducted to measure the power transmission performance of the prototype.

Optimal design of sandwich panel for transmission noise reduction (투과 소음 저감을 위한 샌드위치 패널 최적 설계)

  • Yoon, Hong Geun;Lee, Jin Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.116-118
    • /
    • 2014
  • A shape optimization problem is formulated to optimally design aluminum sandwich panel, which is used for high speed railway vehicle. An aluminum volume used in the panel is selected as a design objective with constraints on the stiffness and the transmission loss value. The formulated shape optimization problem is solved for a well -selected initial shape. The stiffness and transmission loss value of the obtained optimal shape are compared with those of the previously-reported panel.

  • PDF

Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation (낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준)

  • Woo, J.W.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.