• Title/Summary/Keyword: Transmission characteristic

Search Result 1,001, Processing Time 0.034 seconds

Design and implementation of dual-mode narrow-band waveguide channel filter using measured iris transmission loss data (Iris 전송손실 측정값을 이용한 이중모드 협대역 도파관 채널여파기의 설계 및 제작)

  • 정근욱;이재현
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.19-28
    • /
    • 1995
  • In this paper, measured iris transmission loss data and simulated data by using 3-dimension full-wave analysis S/W are presented and compared with Marcuvitz's theory. And by using measured iris data, dual-mode narrow-band channel filters can be successfully implemented. This paper shows that there is severe difference between the transmission loss of iris calculated by using Marcuvitz's equation to calculate iris dimension, if the length of slot iris is longer than .lambda./.pi., and in the long urn the response of channel filter is distorted. Experimental result shows that the characteristic response of implemented channel filter by using the iris transmission loss graph presented here matches well the design specfications. In conclusion, iris transmission loss measurement method will be very useful to design channel filter.

  • PDF

Study on Group Delay Distortion in Data transmission by Means of Public Switching Telephone Network (PSTN) (공중교환전화망 (PSTN)에 의한 데이터 전송에 있어서의 군지정 #곡에 관한 연구)

  • 조규심;박규태
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.4
    • /
    • pp.24-30
    • /
    • 1984
  • Group delay distortion (phase distortion) is a characteristic which is of no account from a standpoint of voice transmission. But this distortion becomes the major source of distortion in wave form transmission such as data, FAX and others over the public switching telephone network (voice band transmission) so that it must be drastically studied. This paper makes analysis of group deray distortion of the telephone network, describs experimental and measuring results and refers also to the improvement of distortion for the purpose of opening the public switching telephone network to data transmission.

  • PDF

A Study on the Dynamic Analysis Modeling of Industrial Robot's Wrist Power Transmission (산업용 로봇 손목 동력 전달계의 동특성 해석 모델 연구)

  • 김우형;정두한;최영삼;정진태;임흥순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.243-246
    • /
    • 2004
  • The dynamic characteristic of a wrist power transmission examine closely with mass property, to present the model which induce the vibration is ultimately the purpose. A robot wrist power transmission for analysis model got the mass property through the approach to be the experimental. A bearing equivalent stiffness which supports the axis and a gear contact equivalent stiffness are determined by the simplicity analysis model compared the result of the experiment. We calculate the vibration tendency of the robot wrist power transmission by an analysis tool which is called the RecurDyn. We compared it with a signal analysis experiment's which a robot operation happens which is based on the ambient noise.

  • PDF

Electrical Flashover Characteristic Test by Gas Flames(I) (화염에 의한 전기적 섬락특성 실험(I))

  • Sohn, H.K.;Lee, H.K.;Han, H.J.;Park, I.P.;Han, S.W.;Kim, B.G.;Oh, H.H.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.450-451
    • /
    • 2008
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. Therefore, by studying flame's electrical conductivity, the paper recommended measures that can minimize transmission line's flashover accidents in the future, which can be caused by forest fire in a region where transmission lines pass through.

  • PDF

Implementation of Low Loss Radome with Hexa mesh for Ku-Band

  • Seo, Kang;JeongJin, Kang
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.555-560
    • /
    • 2022
  • In this study, the insertion loss and phase delay according to the multi-layer structure radome parameters were analyzed using the boundary value solution approach, and the multi-layer structure and hexa mesh structures with low-loss electrical characteristics for the Ku-band transmission/reception frequency of 10.7 ~ 14.5 GHz were designed and manufactured. A hexa mesh was applied to minimize radio wave transmission and scattering, which lowered the transmittance refractive index according to the radio incident angle and minimized dielectric loss through high-density foam. Similar to the simulation result, the transmission loss obtained the gain in a specific receiving frequency band, and in the transmission frequency band, an excellent low loss characteristic was obtained with an insertion loss of 0.8dB or less. The results of this study can be used in radio transmission radomes of low-weight, low-cost end-system protection devices.

Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line (초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석)

  • Lim, Jae-Seop;Shin, Koo-Yong;Lee, Dong-Il;Ju, Mun-No;Yang, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

A Stepped Impedance Resonator Bandpass Filter with Superior Cut-off Response for ITS Application (우수한 차단 특성을 갖는 ITS용 SIR 대역 통과 여파기)

  • Nam Hee;Yun Tae-Soon;Lee Myeong-Gil;Lee Jong-Chul;Hong Ui-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.3 s.8
    • /
    • pp.73-78
    • /
    • 2005
  • In this paper, a bandpass filter with excellent cut off characteristic due to transmission zero using bypass coupling capacitor and with superior harmonic characteristic by interdigital capacitor is suggested. The measurement results for SIR bandpass filter with bypass coupling capacitor and interdigital capacitor show that the insertion loss is less than 1.9 dB and the return loss is better than 15.4 dB with 4.2 % bandwidth at the center frequency of 5.78 GHz.

  • PDF

Permittivity Characteristic Analysis of Planar Substrates Using H-shaped Resonant Aperture (H-모양 공진 개구를 이용한 평면 기판의 유전율 특성 분석)

  • Yeo, Junho;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.55-56
    • /
    • 2018
  • In this paper, a method for analyzing the dielectric constant of a planar substrate is proposed. To this end, a band-stop filter was created by adding a H-shaped resonant aperture to the ground plane of a microstrip transmission line. A planar substrate of 2 mm thickness was placed behind the ground plane of the microstrip transmission line and the change of the resonant frequency with the change of the dielectric constant of the substrate was investigated. It can be seen that the change ratio of the frequency to the reference resonant frequency is larger than that of the conventional complementary split ring resonator structure.

  • PDF

A Study on Insulation Performance Enhancement of Existing Transmission Line Considering Overvoltage Analysis Result and Fault Characteristic (과전압 분석 결과와 고장특성을 고려한 기설 송전선로의 절연보강 방법에 관한 연구)

  • Kwak, Joo-Sik;Woo, Jung-Woog;Koo, Kyo-Sun;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.162-168
    • /
    • 2009
  • This paper describes a study that is to redesign insulation of transmission lines and determine required the numbers of insulators in order to enhance the insulation performance of existing transmission lines which were constructed with standard insulation design, considering overvoltage analysis results, probabilities and characteristics of faults. To ensure proper insulation distance without deteriorating the required performance, EMTP model is established to calculate maximum overvoltage in the line. The fault records and predicted outage rates due to lightning and contamination in the line were investigated and analyzed respectively. It presents a method to determine the numbers of insulators considering the probability and the characteristic of fault.

The Data Compression Method for increase of Efficiency in Tactical Data Communication over Legacy Radios (Legacy Radio 기반의 전술데이터 통신 효율성 향상 위한 데이터 압축 기법)

  • Sim, Dong-Sub;Shin, Ung-Hee;Kim, Ki-Hyung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.577-585
    • /
    • 2010
  • The Military Tactical Communication technology for effective network-centric warfare is developing. Targeting broadband wireless transmission, core technology for connection, and Transmission technology that secure survivability under High-speed Movement environment. On the one hand, Tactical data communication system that reflects military characteristic is developing on the base of Legacy communication equipment which is used in the field. Because almost every military units in the field have used voice to communicate which lower efficiency of operation, they have made effort to Substitute voice communication which delays military Operation Tempo to digital communication. The Communications environment of troops in Forward edge of battle field area is very poor. Especially in terms of limited frequency allocation and bandwidth. Therefore, improving the efficiency of frequency is essential for Military Tactical Communication. This paper is about The Data Compression Method for increase of Efficiency in Tactical Data Communication over Legacy Radios which are UHF, VHF, HF Radio. I proposed and proved the most efficient Data Compression Method that reflects military characteristic, after analyzing the experimentation, which simulate CAS(Close Air Support mission) data transmission between Pilot and TACP.