154kV 지중 POF 케이블의 부식방지(腐蝕防止)에 관한 연구(硏究) (A Study on the Corrosion Control and Protection of 154kV Underground Pipe-type Oil Filled (POF) Cable)

  • 이동일;김정부;정동원;김대경;이종범;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.161-165
    • /
    • 1990
  • KEPCO has experienced eight oil leakage failures due to POF cable corrosion in the 154KV underground POF cable transmission line since the line was operated in 1976. Experimentally, We have verified that the cause of the failure is electrolytic corrosion of the cable owing to subway leakage current. For the countermeasure, We adopted the total Cathodic Protection System by the use of Victim Anode, Forced Drainage Method and Impressed Current Method with polarization cell.

  • PDF

리튬이차전지용 Si-M (M : Cr, Ni) 합금 음극의 미세구조와 전기화학적 특성 (Microstructures and Electrochemical Properties of Si-M (M : Cr, Ni) as Alloy Anode for Li Secondary Batteries)

  • 이성현;성재욱;김성수
    • 전기화학회지
    • /
    • 제18권2호
    • /
    • pp.68-74
    • /
    • 2015
  • 본 실험에서는 리튬이차전지의 고용량 음극활물질로 주목받는 Si 합금의 부피팽창을 억제하기 위한 방법의 하나인 비활성-matrix상을 이용하고, 상태도를 이용하여 동일한 용량을 발현하는 Si계 이원계 합금 (Cr-Si, Ni-Si) 조성에서의 미세구조 및 전기화학적 특성을 비교/분석하였다. 급속응고공정(Rapid Solidification Process, Melt-spinning법)를 이용하여 동일조건하에서 리본 모양의 합금을 제작하였고, 제작된 리본합금은 동일조건에서 분쇄하여 X-선회절 (X-Ray Diffraction) 분석을 실시하였다. XRD 분석 결과, 상태도에서 예측된 것과 같이, 두 합금 모두 Si 상 및 비활성-matrix상($CrSi_2$$NiSi_2$)이 관찰되었으며, 이외의 제3의 상은 관찰되지 않았다. 또한, 주사전자현미경(SEM, Scanning Electron Microscope) 및 투과전자현미경-에너지분산분광법(TEM-EDS, Transmission Electron Microscopy - Energy Dispersive X-ray Spectroscopy)으로 미세구조를 살펴본 결과 Cr-Si 합금의 미세구조가 Ni-Si 합금보다 fine한 것을 알 수 있었고 이것은 상태도로부터 예측 가능하였다. 두 합금 조성에서 미세구조에 따른 전기화학적 특성을 비교 평가하기 위해 코인형 하프셀과 풀셀로 충방전 실험을 진행하였고 이와 별도로, 전극의 두께변화 측정이 가능하게 설계된 시험셀을 이용하여 반응 중 Si의 수축팽창을 측정하였다. coarse한 미세구조를 가진 Ni-Si 합금보다 fine한 미세구조를 갖는 Cr-Si 합금의 전극팽창이 비교적 잘 억제됨을 확인하였고, 충방전에 따른 수명 내구성도 우수함을 확인하였다. 이런 결과들로부터 합금의 조성에 따른 미세구조, 체적변화 및 전기화학적 열화와의 연관성을 유추할 수 있었다.

Pt-Ru/C 촉매를 이용한 직접메탄을 연료전지 운전 특성 (Operating Characteristics of Direct Methanol Fuel Cell Based on Pt-Ru/C Anode Catalyst)

  • 정두환;이창형;김창수;전영갑;신동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1252-1254
    • /
    • 1997
  • Direct methanol fuel cell based on a proton-exchange membrane electrolyte was investigated. 60% Pt-Ru/C and 60%Pt/C catalysts were employed for methanol oxidation and oxygen reduction, respectively. Morphologies of the catalysts were investigated by x-ray power diffraction, energy dispersive x-ray spectroscopy, and transmission microscopy. Electrochemical characteristics of the catalysts were tested by using cyclic voltametry technique. I-V characteristics of the fuel cell were tested by changing methanol concentration, temperature, and Nafion type as a proton-exchange membrane electrolyte. AC impedance technique was used to investigate the electrochemical performance of the fuel cell. The performance of single cell was enhance with increasing cell temperature. High operation temperature attributed to the combined effects of the reduction of ohmic resistance and polarization. High cell voltage was obtained from the concentration of 205M methanol. With Nafion 112, a current density of $230mA/cm^2$ at 0.55V was obtained from the concentration of 2.5M methanol.

  • PDF

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

미소초점엑스선원 개발을 위한 전산모사 (Computer Simulation for Development of Micro-Focus X-ray Generator)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.403-408
    • /
    • 2011
  • MFX tube를 개발하기 위하여, MFX tube 내에서 전계방출음극으로부터 방출된 전자의 궤적을 SIMION 프로그램을 이용하여 전산모사하였다. 전자의 출발위치와 상관없이 emitter에서 방출된 전자빔을 한곳에 집중시킬 수 있는 optimum extractor voltage Ve가 존재한다는 것을 알아내었다. Extractor voltage Ve는 source voltage Vs에 따라 변하지만, 두 전압의 비율(Ve/Vs)는 항상 일정하고, 그 값은 99.4%였다. Source와 extractor에 인가된 전압의 비율(Ve/Vs)이 99.4%일 때, 교차점에서의 빔 직경은 $1.2{\mu}m$였다. MFXG의 초점 크기는 교차점에서의 beam diameter보다 작을 수 없기 때문에, 교차점에서의 beam diameter을 작게 할 수 있는 조건을 찾는 것은 중요하다. 따라서 위의 두 결과는 MFX tube의 개발에 있어서 매우 중요한 결과로 판단된다.

휴대용 XRF 장치의 검출감도 향상에 관한 연구 (Study for Enhancement of the Detection Sensitivity in Hand-Held X-Ray Fluorescence Device)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.409-415
    • /
    • 2011
  • 현재 개발 중인 휴대용 XRF (X-Ray Fluorescence) 장치의 검출감도를 향상시키기 위한 방법을 논의하였다. 대기 기체분자에 의한 강도 손실을 최소화하기 위하여 시료와 검출기 사이에 Vacuum module을 설치하였다. Vacuum module은 대기기체 또는 He 기체를 채울 수 있도록 고안하였다. 그리고 Vacuum module 내부에 He 기체를 채운 상태, 또는 진공상태에서 검출감도의 변화를 조사하였다. 그 결과 다음 3가지 중요한 결과를 얻었다. 첫 번째는, 낮은 에너지 영역(3~4 keV)에서의 XRF 강도가 2~4배 정도 증가하였다. 검출감도의 향상은 검출시간의 단축을 의미하기 때문에, 휴대용 XRF 장치에 있어서 매우 중요한 결과이다. 두 번째는, x-ray emission line의 에너지가 3 keV 이하인 원소의 검출 가능성을 확인하였다. 세 번째는, He 기체를 채운 vacuum module을 사용하면, 휴대용 XRF 장치에 진공밀폐용기를 쓰지 않으면서도 대기기체분자에 의한 흡수를 최소화할 수 있다는 것이다. 세 가지 모두 휴대용 XRF 장치의 개발에 있어서 매우 의미있는 결과로 판단된다.