• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.026 seconds

Development of Inter-link Converter for Power Transmission between Heterogeneous Systems (이종 계통 간의 전력전달을 위한 Inter-link 컨버터 개발)

  • Kim, Sun-Pil;Kim, Kuk-hyeon;Lee, Chang-ho;Le, Tuan-Vu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.111-119
    • /
    • 2022
  • This paper is about power transfer between heterogeneous systems in zero-energy buildings. Currently, electricity used in buildings, from renewable energy generation power in buildings, consists of alternating current networks. In order to use electricity, alternating current must be converted to direct current, which typically results in a loss of 10%. In order to solve this problem, research is needed to reduce power loss as much as possible by implementing both a DC network and an AC network in a zero-energy building. Therefore, in this paper, an inter-link converter capable of bidirectional power transfer between DC and AC networks applied to zero-energy buildings is developed. The structure of the inter-link converter to be developed was proposed and its feasibility was verified through simulations and experiments.

Comparison with Dispersion Compensation Scheme Using 10 Gbit/s × 40 Channels Wavelength Division Multiplexing Transmission over 323 km of Field Installed Non-Zero Dispersion Shift Fiber

  • Kim, Geun-Young;Park, Soo-Jin;Jeong, Ki-Tae
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.112-117
    • /
    • 2006
  • We experimentally investigated the transmission characteristics of 400 Gbit/s (10 Gbit/s ${\times}$ 40 channels) WDM signals with 100 GHz channel spacing over 323 km of installed NZ_DSF. The installed fiber has optical properties of 0.28 dB/km attenuation, 4.3 ps/nm/km dispersion, $0.083ps/nm^2/km$ dispersion slope and less than $0.05ps/km^{1/2}$ PMD coefficient. In this experiment, two cases of dispersion compensation schemes, the lumped type and the distributed type, were compared. The results implied that the distributed type dispersion compensation in which dispersion compensation devices are inserted at the end of the each span showed better transmission performance than the lumped one in which dispersion compensation devices are located at the transmitter and receiver sites. From the analysis of the experimental results, we verified that different transmission performance comes from the power penalty induced by XPM in the distributed scheme is lower than the lumped scheme case.

A Compact Lumped-Element Low-Pass Filter with Transmission Zeros

  • Lee, Byoung-Hwa;Park, Sang-Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.35-38
    • /
    • 2003
  • In this paper, compact lumped-element low-pass filter structure with two transmission zeros at second and third harmonics is presented. The use of lumped-elements and transmission zeros can provide the advantages of compact size, sharp cutoff and wide stop-band frequency response. The proposed low-pass filter is a modified Chebyshev low-pass filter type and is implemented by the use of low temperature co-fired ceramic (LTCC) technology. This filter has been verified by both simulation and experiment. The simulated and experimental results agree very well.

Calculation on the Ion Flow Field under HVDC Transmission Lines Considering Wind Effects

  • Wu, Jing;Gao, Sheng;Liu, Yuxiao
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2077-2082
    • /
    • 2015
  • Based on Deutsch assumption, a calculation method on the electric field over the ground surface under HVDC transmission lines in the wind is proposed. Analyzing the wind effects on the electric field and the space charge density the existing method based on Deutsch assumption is improved through adding the wind speed to the ion flow field equations. The programming details are illustrated. The calculation results at zero wind speed are compared with available data to validate the code program. Then the ionized fields which resulted from corona of ±800kV HVDC lines are analyzed. Both the electric field and the current density on the ground level are computed under different wind direction and speed. The computation results are in good agreement with measurements. The presented method and code program can be used to rapidly predict and evaluate the wind effects in HVDC transmission engineering.

Transmission Probability Control Scheme in FSA-based RFID Systems

  • Lim, In-Taek
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.6
    • /
    • pp.677-681
    • /
    • 2010
  • This paper proposes a transmission probability control scheme for enhancing the performances of FSA-based RFID system. In order to maximize the system performance, the number of tags attempting to transmit their identifiers in a frame should be kept at a proper level. The reader calculates the transmission probability according to the number of tags within the identification range of reader and then broadcasts it to tags. Tags, in which their slot counter values reach to zero, attempt to transmit their identifiers with the received probability. Simulation results show that the proposed scheme can offer better throughput and delay performance than the conventional one regardless of the number of tags.

An Enhanced Skirt Characteristics Triple-Mode Filter

  • Lee, Ja-Hyeon;Nam, Hun;Lim, Yeong-Seog
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.3
    • /
    • pp.210-215
    • /
    • 2012
  • This paper presents a compact microstrip triple-mode filter with enhanced skirt characteristics. The presented triple-mode filter configuration supports three transmission poles and three transmission zeros within the nearby passband. Two of transmission zeros are generated by a triple-mode resonator itself, and the third one is generated by small cross-couplings between the I/O ports. Each resonance condition and the transmission zero generation conditions are analyzed using an equivalent circuit. The bandpass filter is designed for a 2.4 GHz WLAN. The filter was fabricated with a relative dielectic constant of 3.5 and a thickness of 0.76 mm. The fabricated filter has a small size ($7.9mm{\times}7.2mm$, i.e., $0.107{\lambda}_g{\times}0.098{\lambda}_g$, where ${\lambda}_g$ is guided wavelength at a center frequency) and shows high performing skirt characteristics.

Bit-rate Scalable Video Coder Using a $2{\times}2{\times}2$ DCT for Progressive Transmission

  • Woo, Seock-Hoon;Park, Jin-Hyung;Won, Chee-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.66-69
    • /
    • 2000
  • In this paper, we propose a progressive transmission of a video using a 2$\times$2$\times$2 DCT First of all, the video data is transformed into multiresolution represented video data using a 2$\times$2$\times$2 DCT. Then. it is represented by a 3-D EZT(Embedded Zero Tree) coding fur the progressive transmission with a bit-rate scalability. The proposed progressive transmission algorithm needs much less computations and buffer memories than the higher-order convolution based wavelet filter. Also, since the 2$\times$2$\times$2 DCT requires independent local computations, parallel processing can be applied.

  • PDF

Performance Evaluation of A Tunable Dispersion Compensator based on Strain-Chirped Fiber Bragg Grating in a 40 Gb/s Transmission Link

  • Kim, Chul-Han;Bae, Jun-Key;Lee, Kwan-Il;Lee, Sang-Bae
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.244-248
    • /
    • 2008
  • We have evaluated the performance of strain-chirped fiber Bragg grating (FBG) based tunable dispersion compensator in a 40 Gb/s transmission link. In our proposed compensator, the value of dispersion could be changed from -353 ps/nm to -962 ps/nm by adjusting the rotation angle of the metal beam on which the FBG was mounted. In order to evaluate the effect of ripples in reflectivity and variations in passband of the FBG based dispersion compensator, transmission performance has been measured with our tunable dispersion compensator. Error-free transmission of a 40 Gb/s non-return-to-zero (NRZ) signal over conventional single-mode fiber (SMF) was achieved.

A Study on the Fault Discrimination and Location Algorithm in Underground Transmission Systems Using Wavelet Transform and Fuzzy Inference (지중송전계통에서 Wavelet 변환과 퍼지추론을 이용한 고장종류판별 및 고장점 추정에 관한 연구)

  • Park, Jae-Hong;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.116-122
    • /
    • 2006
  • The underground transmission lines is continuously expanded in power systems. Therefore the fault of underground transmission lines are increased every year because of the complication of systems. However the studies dealing with fault location in the case of the underground transmission lines are rarely reported except for few papers using traveling wave method and calculating underground cable impedance. This paper describes the algorithm using fuzzy system and travelling wave method in the underground transmission line. Fuzzy inference is used for fault discrimination. To organize fuzzy algorithm, it is important to select target data reflecting various underground transmission line transient states. These data are made of voltage and average of RMS value on zero sequence current within one cycle after fault occurrence. Travelling wave based on wavelet transform is used for fault location. In this paper, a variety of underground transmission line transient states are simulated by EMTP/ATPDraw and Matlab. The input which is used to fault location algorithm are Detail 1(D1) coefficients of differential current. D1 coefficients are obtained by wavelet transform. As a result of applying the fuzzy inference and travelling wave based on wavelet transform, fault discrimination is correctly distinguished within 1/2 cycle after fault occurrence and fault location is comparatively correct.

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.