• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.028 seconds

Short packet communication in underlay cognitive network assisted by an intelligent reflecting surface

  • Pham Ngoc Son;Tran Trung Duy;Pham Viet Tuan;Tan-Phuoc Huynh
    • ETRI Journal
    • /
    • v.45 no.1
    • /
    • pp.28-44
    • /
    • 2023
  • We propose short packet communication in an underlay cognitive radio network assisted by an intelligent reflecting surface (IRS) composed of multiple reconfigurable reflectors. This scheme, called the IRS protocol, operates in only one time slot (TS) using the IRS. The IRS adjusts its phases to give zero received cumulative phase at the secondary destination, thereby enhancing the end-to-end signal-to-noise ratio. The transmitting power of the secondary source is optimized to simultaneously satisfy the multi-interference constraints, hardware limitations, and performance improvement. Simulation and analysis results of the average block error rates (BLERs) show that the performance can be enhanced by installing more reconfigurable reflectors, increasing the blocklength, lowering the number of required primary receivers, or sending fewer information bits. Moreover, the proposed IRS protocol always outperforms underlay relaying protocols using two TSs for data transmission, and achieves the best average BLER at identical transmission distances between the secondary source and secondary destination. The theoretical analyses are confirmed by Monte Carlo simulations.

Insulation Level Assessment on the Military Residential Facilities Considering the Investment Payback Period (투자회수기간을 고려한 군 주거시설의 단열수준 산정 연구)

  • Park, Young Jun;Meang, Joon Ho;Kim, Taehui;Kim, Sung Joong;Lee, Seung-Min;Son, Kiyoung
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • Purpose: This study, which is based on the investment payback periods, aims to suggest the proper insulation level which can be adapted to the Defense Military Facility Criteria regarding the military residential condominiums. For the energy performance simulation, it is required to collect the residential data regarding the military condominiums and climatic data concerning the regions they belongs to. The estimates through energy performance simulation are the regional heating loads and the heating transmission coefficients of building components. Method: With the heating loads, the annual heating cost saving per square meters is assessed. With the heating transmission coefficients of building components, the additional insulation installment cost per square meters is evaluated. With two outcomes, one as an annual value and the other as a present value, the investment payback period is calculated. Result: In result, it could be concluded that 55~70% insulation ratio can lead a superior residental environments as well as be contributed to the national policy associated with zero-energy buildings because the estimated investment payback period is shorter than the life span of the military residental condominiums. This upshot can be used as a foundation to enactment the Defense Military Facility Criteria associated with military residential condominiums.

Long haul transmission link using a optimized circulating loop for optical wavelength division multiplexing signals (최적화된 반복루프를 이용한 파장분할다중화 광신호 장거리 전송)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1757-1763
    • /
    • 2014
  • Optical wavelength division multiplexing signals of eight non-return-to-zero 10 Gb/s channels were transmitted on the long-haul link up to 720 km. The link span was composed of 80 km single mode fiber, dispersion compensation fiber for complete compensation, and EDFAs. A circulating loop method was applied to the link experiment and the loop was optimized for the transmission link. Wavelength-dependent gain variation of EDFA was compensated using EDFAs of opposite gain slopes without expensive gain flattening filters. Average OSNR was aggravated to 22 dB and the worst OSNR channel variation was 9.7 dB after the transmission. It was confirmed by analyzing optical spectra that this OSNR variation was mainly caused by the hole burning effect of EDFA.

Deadbeat and Hierarchical Predictive Control with Space-Vector Modulation for Three-Phase Five-Level Nested Neutral Point Piloted Converters

  • Li, Junjie;Chang, Xiangyu;Yang, Dirui;Liu, Yunlong;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1791-1804
    • /
    • 2018
  • To achieve a fast dynamic response and to solve the multi-objective control problems of the output currents, capacitor voltages and system constraints, this paper proposes a deadbeat and hierarchical predictive control with space-vector modulation (DB-HPC-SVM) for five-level nested neutral point piloted (NNPP) converters. First, deadbeat control (DBC) is adopted to track the reference currents by calculating the deadbeat reference voltage vector (DB-RVV). After that, all of the candidate switching sequences that synthesize the DB-RVV are obtained by using the fast SVM principle. Furthermore, according to the redundancies of the switch combination and switching sequence, a hierarchical model predictive control (MPC) is presented to select the optimal switch combination (OSC) and optimal switching sequence (OSS). The proposed DB-HPC-SVM maintains the advantages of DBC and SVM, such as fast dynamic response, zero steady-state error and fixed switching frequency, and combines the characteristics of MPC, such as multi-objective control and simple inclusion of constraints. Finally, comparative simulation and experimental results of a five-level NNPP converter verify the correctness of the proposed DB-HPC-SVM.

Method of Generating Information Signals in the System Industrial Internet of Things

  • Aleksandr Serkov;Nina Kuchuk;Bogdan Lazurenko;Alla Horiuskina
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.4
    • /
    • pp.206-210
    • /
    • 2024
  • Industrial facilities that use modern IT technologies require the ensured reliability and security of information in automated enterprise management. Concurrently, so as to ensure a high quality of communication, it is necessary to expand the bandwidth of communication channels, which are limited by the physical parameters of the radio frequency spectrum. In order to overcome this contradiction, we propose the application of technology fundamental to ultra-wideband signals, in which the ratio between the bandwidth and its central part is greater than "one". For this reason, the information signal is emitted without a carrier frequency - simultaneously within the entire frequency band - provided that the signal level is lower than the noise level. For the transmission of information content, the method of positional-time coding is used, in which each information bit is encoded by hundreds of ultrashort pulses that arrive within a certain sequence. Mathematical models of signals and values observed in wireless communication systems with autocorrelation reception of modulated ultra-wideband signals are furthermore recommended. These assist in identifying features of the dependence of the error probability on the normalized signal-to-noise ratio and the signal base. Comparative analysis has shown that the best noise immunity of the systems considered in this paper is the communication system, which uses the time separation of the reference and information signals. During the first half of the bit interval, the switch closes the output of the transmitter directly to the generator of the ultra-wideband signal - forming a reference signal. In the middle of the bit interval, the switch alternates the output to one of two possible positions depending on the encoding signal - "zero" or "one", forming the information part of the ultra-wideband signal. It should also be noted that systems with autocorrelation reception and separate transmission of reference and information signals, provide a high level of structural signal secrecy. Furthermore, they provide the reliable transmission of digital information, especially in interference conditions.

Low-Pass Filter with Wide Stop-Band Characteristics Using Controllable Transmission Zeros (제어 가능한 전송 영점을 이용한 광대역 차단 특성을 갖는 저역 통과 필터)

  • Lee, Geon-Cheon;Kim, Yu-Seon;Kim, Kyung-Keun;Lee, Tae-Sung;Na, Hyeon-Sik;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.887-894
    • /
    • 2007
  • In this paper, design and fabrication of the LPF with controllable four transmission zeros using electric coupling and added open stub is presented. Pass-band of the LPF is GSM band, and two transmission zeros are generated by the electric coupling at the WiBro and S-DMB band, And the other two transmission zeros are generated by the open stub at the upper frequencies. Harmonic frequency of the stop-band is suppressed by the realization of the filter using quasi-lumped element with small parasitic values. $C_M$, which is the electric coupling element of the equivalent circuit, is realized by the distance control between the open stubs of the filter structure. The fabricated LPF used teflon substrate with relative permittivity of 2.6. And it has a size of $38{\times}20{\times}0.79 mm^3$, which is including a feed line. The measured 3 dB cut-off frequency is 1.55 GHz, and locations of the transmission zeros are 2.20, 2.43, 4.11 and 6.84 GHz, respectively.

Thermal and Water Transmission Properties of Vapor Permeable Water Repellent Fabrics and Thermal Insulation Batting Materials (투습발수직물과 보온단열소재의 열 및 수분전달 특성)

  • Cho Gil Soo;Choi Jong Myoung;Lee Jung Ju;Lee Sern Woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.2
    • /
    • pp.237-244
    • /
    • 1992
  • The purpose of this study was to comparatively evaluate thermal and water transmission properties of several vapor permeable water repellent (VPWR) fabrics and synthetic battings that became available in recent years. Five VPWR fabrics evaluated were Hipora in three coating variants, $Gore-Tex^{\circledR}$ and $Aitace^{\circledR}$. Battings evaluated were $Viwarma^{\circledR}$, $Uniwarmr^{\circledR}$, $Thinsulate^{\circledR}$, and $Airseal^{\circledR}$ Thermal resistance and water vapor transmission were measured for each fabric and batting and in all combinations. Thermal resistance at zero and 37 cm/sec air velocity was determined by the Thermo Labo II technique for simultaneously measuring conduction and radiation heat transfer. Water vapor transmission over 24 hours was measured by a modified weight-gain method in a compact humid chamber at conditions simulating the clothing climate under heavy exercise ($40{\pm}1^{\circ}C$, $90{\pm}2\%$ R.H., and 0.5 m/sec air velocity). Fabric porosity was calculated from fiber density and fabric weight, thickness, and area. Thermal resistance results for the fabrics showed the effectiveness of coatings in inhibiting heat transfer. Measurements taken in wind were: $31.1\~37.6\%$ for $Hipora^{\circledR}$ variants; $31.0\%$ for $Gore-Tex^{\circledR}$; and $18.4\%$ for $Aitaca^{\circledR}$ Measurements without wind were higher but in the same order. Water vapor transmission results were in reverse order: $Aitac^{\circledR}$, $8.8 kg/m^{2};\;Gore-Tex^{\circledR}$, 6.4 kg/$m^{2}$; and $Hipora^{\circledR},\;4.4\~6.0\;kg/m^{2}$. In general thermal resistance increased with porosity. For battings, the thermal resistance with wind results were: $Viwarmu^{\circledR}$, $65.0\%;\; Thinsulate^{\circledR}$, $62.0\%$; $Uniwarm^{\circledR}$, $61.0\%$; and $Airseala^{\circledR},\;53.1\%$. Thermal resistance was proportional to thickness. Thermal resistance of fabric-batting combinations were $20\%$ higher than those of the battings only. Water vapor transmission for combinations was mainly affected by that for the VPWR fabric used.

  • PDF

A channel estimation scheme in Unique-Word based SC-FDE system for terrestrial 3DTV transmission (Unique_Word 기반 SC-FDE 시스템에서 지상파 3DTV 전송을 위한 채널 추정 기법)

  • Shin, Dong-Chul;Kim, Jae-Kil;Ahn, Jae-Min
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.125-126
    • /
    • 2010
  • 채널의 다중경로를 통과한 신호들은 지연확산 영향으로 심하게 왜곡이 되거나 Inter-Symbol Interference(ISI)가 발생하므로 왜곡된 채널을 추정하여 보상해야 한다. 기존 iterative 채널 추정 방식에서는 채널 시간 지연 길이 밖으로 zero padding함으로 노이즈 성분을 제거하는 알고리즘이다. 반면에 본 논문은 채널 시간 지연 길이 안으로 있는 노이즈 성분까지 노이즈 제거 문턱 값 추정(noise elimination threshold estimation: NETE) 알고리즘을 사용하여 노이즈를 효과적으로 제거한다. 시뮬레이션 결과는 채널의 mean square error(MSE)를 통하여 제안된 기법을 적용할 경우 채널 추정 성능 개선이 나타남을 확인할 수 있었다.

  • PDF

Multiple Description Coding using Unequal MDSQ in Wavelet Domain

  • Yoon, Eung-Sik;Park, Kwang-Pyo;Lee, Keun-Young
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.281-284
    • /
    • 2002
  • Error resilience for image coding is an important component of multimedia communication system. Error resilience schemes address loss recovery from the compression perspective. Multiple description coding (MDC) is one of the error resilience techniques promising for robust video transmission. It is the way to achieve tradeoff description such as scalar quantization, correlating transform and the quantized frame expansion. In this paper, we consider Multiple Description Scalar Quantization (MDSQ) to wavelet domain. Conventional MDSQ schemes considered description with equal weights in each sub-bands. But, we can see that the each sub-bands is unequal contribution to whole image quality. Therefore, we experiment the multiple design MDSQ table to make probability of zero index high, which gives high efficiency in arithmetic symbol coder. We also compare our proposed method with the conventional methods and show improved performance in terms of redundancy-rate-distortion.

  • PDF

Strengthening Authentication Through Content Centric Networking

  • Kim, Sung-Jin;Park, Jae-Kyung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.4
    • /
    • pp.75-82
    • /
    • 2017
  • While the internet has evolved in terms of information sharing and efficiency, it is still prone to security attacks and remains vulnerable even when equipped with a security mechanism. Repeated patching against hacks involves excessive wear of system equipment and high costs. Methods of improving network security include the introduction of security equipment and network partitions, but they have not been fully effective. A fundamental solution is the Operation Content Network (OCN), which enables the strengthening of authentication. In this paper, Instead of following the existing TCP/IP system, OCN establishes an immunity-based security system through content-centric communications. Data transmission occurs over a Content Centric Network (CCN), which is provided with a protocol verified by the CCNx group. Areas protected by OCN rely only on CCN for communication without using any IP. As such, it defends the system against unknown attacks, including zero-day attacks.