• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.027 seconds

Hydraulic Experiments on Transmission Coefficients for Vertical Structure under Intermediate Water Depth Condition (중간수심역 조건에서 직립식 구조물의 전달파고계수 산정에 관한 수리실험)

  • Kim, Young-Taek;Lee, Jong-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 2015
  • Two-dimensional hydraulic model experiments on vertical structures were conducted to investigate wave transmission characteristics under irregular wave condition. The formula about transmission coefficient for the vertical structure was suggested and the results were compared with Goda(1969). Since Goda(1969)'s tests were conducted based on regular waves, the results showed the discrepancy with this study. The Goda's results were relatively higher than the results from the present study. An influence parameter was quantitatively suggested in this study to consider the effect of structural design factors such as the width of structures, the water depth, and the wave length on the wave transmission, while Goda(1969) suggested the mean, upper and lower limits of parameters for the vertical wall(d=h). The transmission coefficients and energy conservation for zero-freeboard conditions were analyzed.

Perinatal outcome and possible vertical transmission of coronavirus disease 2019: experience from North India

  • Sharma, Ritu;Seth, Shikha;Sharma, Rakhee;Yadav, Sanju;Mishra, Pinky;Mukhopadhyay, Sujaya
    • Clinical and Experimental Pediatrics
    • /
    • v.64 no.5
    • /
    • pp.239-246
    • /
    • 2021
  • Background: The consequences of severe acute respiratory syndrome corona virus 2 on mother and fetus remain unknown due to a lack of robust evidence from prospective studies. Purpose: This study evaluated the effect of coronavirus disease 2019 (COVID-19) on neonatal outcomes and the scope of vertical transmission. Methods: This ambispective observational study enrolled pregnant women with COVID-19 in North India from April 1 to August 31, 2020 to evaluate neonatal outcomes and the risk of vertical transmission. Results: A total of 44 neonates born to 41 COVID-19-positive mothers were evaluated. Among them, 28 patients (68.3%) (2 sets of twins) were delivered within 7 days of testing positive for COVID-19, 23 patients (56%) (2 sets of twins) were delivered by cesarean section; 13 newborns (29.5%) had low birth weight; 7 (15.9%) were preterm; and 6 (13.6%) required neonatal intensive care unit admission, reflecting an increased incidence of cesarean delivery and low birth weight but zero neonatal mortality. Samples of cord blood, placental membrane, vaginal fluid, amniotic fluid, peritoneal fluid (in case of cesarean section), and breast milk for COVID-19 reverse transcription-polymerase chain reaction tested negative in 22 prospective delivery cases. Nasopharyngeal swabs of 2 newborns tested positive for COVID-19: one at 24 hours and the other on day 4 of life. In the former case, biological samples were not collected as the mother was asymptomatic and her COVID-19 report was available postdelivery; hence, the source of infection remained inconclusive. In the latter case, all samples tested negative, ruling out the possibility of vertical transmission. All neonates remained asymptomatic on follow-up. Conclusion: COVID-19 does not have direct adverse effects on the fetus per se. The possibility of vertical transmission is almost negligible, although results from larger trials are required to confirm our findings.

Experimental Performance Evaluation of MIMO Underwater Acoustic Communication in Water Tank (수조에서 MIMO 수중음향통신의 실험적 성능 고찰)

  • Gwun, Byung-Chul;Kim, Ki-Man
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1577-1582
    • /
    • 2013
  • In this paper, we have analyzed the performance of MIMO (Multi-Input Multi-Output) underwater acoustic communication by using the acquired data via the experiments in water tank. First of all, in the pursuit of this aim, we have measured the channel transfer characteristics at several transceiver locations. The transmitted signal was modulated by QPSK(Quadrature Phase Shit Keying) and the received signal was recovered through the detector that contains the zero forcing equalizer. A maximum 30~40 ms delay was appeared because of physically closed water tank environment that has the harsh multi-path transmission conditions. In result of experiment, even though the bit error rate showed comparatively large when $2{\times}2$ MIMO system with two transmitters and receivers was considered. However, we confirmed it has approximately 15% enhanced performance compared with SISO (Single-Input Single-Output) system.

Application of Adaptive Neuro-Fuzzy Inference System for Interference Management in Heterogeneous Network

  • Palanisamy, Padmaloshani;Sivaraj, Nirmala
    • ETRI Journal
    • /
    • v.40 no.3
    • /
    • pp.318-329
    • /
    • 2018
  • Femtocell (FC) technology envisaged as a cost-effective approach to attain better indoor coverage of mobile voice and data service. Deployment of FCs over macrocell forms a heterogeneous network. In urban areas, the key factor limits the successful deployment of FCs is inter-cell interference (ICI), which severely affects the performance of victim users. Autonomous FC transmission power setting is one straightforward way for coordinating ICI in the downlink. Application of intelligent control using soft computing techniques has not yet explored well for wireless networks. In this work, autonomous FC transmission power setting strategy using Adaptive Neuro Fuzzy Inference System is proposed. The main advantage of the proposed method is zero signaling overhead, reduced computational complexity and bare minimum delay in performing power setting of FC base station because only the periodic channel measurement reports fed back by the user equipment are needed. System level simulation results validate the effectiveness of the proposed method by providing much better throughput, even under high interference activation scenario and cell edge users can be prevented from going outage.

A Robust Fault Location Algorithm for Single Line-to-ground Fault in Double-circuit Transmission Systems

  • Zhang, Wen-Hao;Rosadi, Umar;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.

Optimized BD-ZF Precoder for Multiuser MIMO-VFDM Cognitive Transmission

  • Yao, Rugui;Xu, Juan;Li, Geng;Wang, Ling
    • ETRI Journal
    • /
    • v.38 no.2
    • /
    • pp.291-301
    • /
    • 2016
  • In this paper, we study an optimized block-diagonal zero-forcing (BD-ZF) precoder in a two-tiered cognitive network consisting of a macro cell (MC) and a small cell (SC). By exploiting multiuser multiple-input and multiple-output Vandermonde-subspace frequency-division multiplexing (VFDM) transmission, a cognitive SC can coexist with an MC. We first devise a cross-tier precoder based on the idea of VFDM to cancel the interference from the SC to the MC. Then, we propose an optimized BD-ZF intra-tier precoder (ITP) to suppress multiuser interference and maximize the throughput in the SC. In the case where the dimension of a provided null space is larger than that required by the BD-ZF ITP, the optimized BD-ZF ITP can collect all limited channel gain by optimizing rotating and selecting matrices. Otherwise, the optimized BD-ZF ITP is validated to be equivalent to the conventional BD-ZF ITP in terms of throughput. Numerical results are presented to demonstrate the throughput improvement of the proposed optimized BD-ZF ITP and to discover the impact of imperfect channel state information.

A Fault Location Algorithm Using Adaptively Estimated Local Source Impedance for a Double-Circuit Transmission Line System (자기단 전원 임피던스 추정 기법을 사용한 병행 2회선 송전선로 고장점 표정 알고리즘)

  • Park, Gun-Ho;Kang, Sang-Hee;Kim, Sok-Il;Shin, Jonathan H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.373-379
    • /
    • 2012
  • This paper presents a fault location algorithm based on the adaptively estimated value of the local sequence source impedance for faults on a parallel transmission line. This algorithm uses only the local voltage and current signals of a faulted circuit. The remote current signals and the zero-sequence current of the healthy adjacent circuit are calculated by using the current distribution factors together with the local terminal currents of the faulted circuit. The current distribution factors consist of local equivalent source impedance and the others such as fault distance, line impedance and remote equivalent source impedance. It means that the values of the current distribution factors can change according to the operation condition of a power system. Consequently, the accuracy of the fault location algorithm is affected by the two values of equivalent source impedances, one is local source impedance and the other is remote source impedance. Nevertheless, only the local equivalent impedance can be estimated in this paper. A series of test results using EMTP simulation data show the effectiveness of the proposed algorithm. The proposed algorithm is valid for a double-circuit transmission line system where the equivalent source impedance changes continuously.

LTE Mobility Enhancements for Evolution into 5G

  • Park, Hyun-Seo;Choi, Yong-Seouk;Kim, Byung-Chul;Lee, Jae-Yong
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1065-1076
    • /
    • 2015
  • Network densification is regarded as the dominant driver for wireless evolution into the era of 5G. However, in this context, interference-limited dense small cell deployments are facing technical challenges in mobility management. The recently announced results from an LTE field test conducted in a dense urban area show a handover failure (HOF) rate of over 21%. A major cause of HOFs is the transmission failure of handover command (HO CMD) messages. In this paper, we propose two enhancements to HO performance in LTE networks - radio link failure-proactive HO, which helps with the reliable transmission of HO CMD messages while the user equipment is under a poor radio link condition, and Early Handover Preparation with Ping-Pong Avoidance (EHOPPPA) HO, which assures reliable transmission of HO CMD under a good radio link condition. We analyze the HO performance of EHOPPPA HO theoretically, and perform simulations to compare the performance of the proposed schemes with that of standard LTE HO. We show that they can decrease the HOF rate to nearly zero through an analysis, and based on the simulation results, by over 70%, without increasing the ping-pong probability.

Design of Dual-Band Bandpass Filter Using Dual-Mode Resonators (이중 모드 공진기를 이용한 이중 대역 대역 통과 필터 설계)

  • Lee, Ja-Hyeon;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.252-257
    • /
    • 2011
  • A compact microstrip dual-band bandpass filter with controllable bandwidth for each passband is proposed. Each passband is independently designed using two different dual-mode resonators. The proposed dual-band bandpass filter has three transmission zeros. Two transmission zeros are generated by each dual-mode resonator. An additional transmission zero is generated by input/output port coupling. The dual-band bandpass filter application is designed for 2.4/5.7 GHz WLAN. Experimental results are presented to validate theory.

Study of the Applicability of the Carson Line Model for the Series Reactance Calculation of the Power Feeding Lines with no Ground Return (전송로의 직렬리앤턴스 산정 시 Carson 모델의 적용범위 검토)

  • Chung, Sang-Gi;Kwon, Sam-Young;Chang, Sang-Hoon;Jang, Dong-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.225-231
    • /
    • 2009
  • In this paper, it is shown that Carson's equation can still be applied for the calculation of the series reactance of transmission lines with no ground return current as well as the one with ground return. It is proved in the following method. First two voltage drop equations for three-phase three wire transmission line are derived, one without considering ground return and the other using Carson's equation. The impedance matrix of the two equations are different from each other. But if we put the condition of zero ground current, $I_a+I_b+I_c=0$, those two equations becomes the identical equations. Therefore even a transmission line is not grounded, its line parameters can still be obtained using the Carson's equation. It has been confused whether or not Carson's equation can be used for an ungrounded system. It is because where ever Carson's equation is shown in the book, it also says that the system has ground return current paths as a premise. It is also verified with EMTP studies on the test circuit.