• Title/Summary/Keyword: Transmission Zero

Search Result 330, Processing Time 0.049 seconds

Performance Analysis of Optical Path Difference on Visible Light Communication System for Intelligent Transport Systems

  • Choi, Jae-Hyuck;Lee, Kye-San;Cha, Jae-Sang;Kim, Jin-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.114-120
    • /
    • 2009
  • In outdoor visible light communication channels and LED road illumination communications for the intelligent transport systems (ITS), inter symbol interference (ISI) due to multipath propagation prevents high data rate transmission. Indoor wireless optical communication systems utilizing white LED lights and on the road illumination have been studying about it. Generally, plural lights are installed in room and considered to the traffic information system using existing LED traffic lights. Therefore, their optical path difference must be considered. In this paper, the influence of an optical path difference has been investigated and two approaches against this problem are introduced. One uses on-off keying, return-to-zero (OOK-RZ) coding and the other uses optical orthogonal frequency division multiplexing(OFDM).

  • PDF

Method for Detection of Saturation of a Current Transformer (전류변성기의 포화 검출을 위한 알고리즘 개발)

  • Nam, Soon-Ryul;Choi, Joon-Ho;Kang, Sang-Hee;Min, Sang-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.879-884
    • /
    • 2009
  • A Method for detection of saturation of a current transformer(CT) is proposed. The algorithm is initiated when the end point of a saturation period is detected. This detection is achieved by checking the time interval between the adjacent zero-crossing points of the second derivative of the secondary current. Once the end point of the saturation period is detected, the beginning point of the corresponding saturation period is determined by backward examination of the sum of the secondary current from the end point. The performance of the algorithm was evaluated for a-g faults on a 345 kV 100km overhead transmission line. The Electromagnetic Transient Program(EMTP) was used to generate fault current signals for different fault inception angles and different remanent fluxes. The performance evaluation shows that the proposed algorithm successfully detects the saturation period even in the presence of a remanent flux.

Spatial Multiplexing Receivers in UWB MIMO Systems based on Prerake Combining

  • An, Jin-Young;Kim, Sang-Choon
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.385-390
    • /
    • 2011
  • In this paper, various ultra-wideband (UWB) spatial multiplxing (SM) multiple input multiple output (MIMO) receivers based on a prerake diversity combining scheme are discussed and their performance is analyzed. Several UWB MIMO detection approaches such as zero forcing (ZF), minimum mean square error (MMSE), ordered successive interference cancellation (OSIC), sorted QR decomposition (SQRD), and maximum likelihood (ML) are considered in order to cope with inter-channel interference. The UWB SM systems based on transmitter-side multipath preprocessing and receiver-side MIMO detection can either boost the transmission data rate or offer significant diversity gain and improved BER performance. The error performance and complexity of linear and nonlinear detection algorithms are comparatively studied on a lognormal multipath fading channel.

Composite Right/Left Handed(CRLH) Transmission Line with Controllable Transmission Zeros (제어 가능한 전송 영점을 갖는 CRLH 전송 선로)

  • Lee, Ja-Hyeon;Kim, Kyoung-Keun;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.583-590
    • /
    • 2010
  • In this paper, a novel CRLH-TL unit cell with controllable transmission zeros was proposed. Proposed composite right/left handed transmission line(CRLH-TL) unit cell is implemented in the form of the metal-insulator-metal(MIM) capacitors, the microstrip stub inductors, and the co-planar waveguide(CPW) inductor. And this proposed CRLH-TL generates two transmission zeros in lower/upper passband by the effort of electromagnetic couplings between each MIM capacitors and microstrip stub inductors. Using this proposed CRLH-TL, broad bandpass filter for UWB system was designed and fabricated. The measured results reveal that the two transmission zeros are observed in lower/upper passband and the overall size of the filter, excluding the feed line is about 8 mm$\times$8 mm, less then $\lambda_g$/4 on electric size.

Design of filters with double coupled line for PCS (이중결합선로를 이용한 PCS용 여파기의 설계)

  • 이창화;구본희김명수이상석
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.387-390
    • /
    • 1998
  • We propose comb-line filter using SIR(Stepped Impedance Resonator) with two transmission line. The coupling structure of the filter is double coupled line where two coupled lines are linked with cascade. We find out the inverter function of the filter. using even and odd mode impedance. The merits of the filter are that first, we can design transmission zero point at any frequency that we wanted without using lumped elements : chip capacitors and inductors. Second, we can design small size filters. To validate the inverter function of the filter with double coupled line we designed and fabricated two-pole band pass filter with the proposed filter structure.

  • PDF

Demonstration of CSRZ Signal Generator Using Single-Stage Mach-Zehnder Modulator and Wideband CMOS Signal Mixer

  • Kang, Sae-Kyoung;Lee, Dong-Soo;Cho, Hyun-Woo;Ko, Je-Soo
    • ETRI Journal
    • /
    • v.30 no.2
    • /
    • pp.249-254
    • /
    • 2008
  • In this paper, we demonstrate an electrically band-limited carrier-suppressed return-to-zero (EB-CSRZ) signal generator operating up to a 10 Gbps data rate comprising a single-stage Mach-Zehnder modulator and a wideband signal mixer. The wideband signal mixer comprises inverter stages, a mixing stage, and a gain amplifier. It is implemented by using a 0.13 ${\mu}m$ CMOS technology. Its transmission response shows a frequency range from DC to 6.4 GHz, and the isolation response between data and clock signals is about 21 dB at 6.4 GHz. Experimental results show optical spectral narrowing due to incorporating an electrical band-limiting filter and some waveform distortion due to bandwidth limitation by the filter. At 10 Gbps transmission, the chromatic dispersion tolerance of the EB-CSRZ signal is better than that of NRZ-modulated signal in single-mode fiber.

  • PDF

Comparison of Methods to Calculate Permeability Parameter of Perforated Wall with Vertical Slits (연직 슬릿 유공벽의 투수계수 계산 방법의 비교)

  • Suh, Kyung-Duck;Ji, Chang-Hwan;Kim, Yeul-Woo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.506-509
    • /
    • 2008
  • Mathematical models have been developed to calculate hydrodynamic characteristics of perforated-wall structures. Most of the models separate the fluid regions into front and back of the wall, assume the solution in each region, and calculate the solution by using the matching condition at the wall. The matching condition involves the permeability parameter, which can be calculated by the methods proposed by Mei et al. or Sollitt and Cross. In this study, we compare these two methods. The former is advantageous because all the related variables are known, but it gives wrong result in the limit of long waves, i.e. zero transmission and perfect reflection of very long waves. In deep water, the latter predicts smaller transmission and larger reflection than the former, and vice versa in shallow water. In the latter method, the friction coefficient decreases as the wall thickness or the porosity of the wall increases.

  • PDF

Charge Distributions and Equipotential lines in Multiconductor Transmission lines (전송선의 전하 분포 및 등전위선 산출)

  • Jung, Baek-Ho;Park, Kyeong-Hee;Kim, Che-Young;Song, Jae-Won;Kim, Soo-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.450-453
    • /
    • 1988
  • A numerical scheme is considered for computing charge distributions and drawing equipotential lines for multiconductor transmission lines with arbitrary cross sections. Two-dimensional integral equation superposed by the charges is numerically calculated by the method of moments. Here in Galerkin's method special pulses cut into halves chosen for expansion and testing functions facilitate the numerical computations in solving the integral equation. Numerical examples are given for some system of which the shell conductor is grounded as the reference zero of potential.

  • PDF

Phase Selection Algorithm using Sequence Voltages for Transmission Line Protection (대칭분 전압을 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myoung-Soo;Kim, Soo-Nam;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.124-126
    • /
    • 2001
  • A reliable fault type identification (phase selection) plays a very important role in transmission line protection, particularly in Extra High Voltage(EHV) networks. The conventional fault type identification algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and identify the fault type in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can identify the accurately fault type using the sum of unit vectors which are calculated by positive-sequence votage and negative-sequence voltage.

  • PDF

Preventing Intra-hospital Infection and Transmission of Coronavirus Disease 2019 in Health-care Workers

  • Gan, Wee Hoe;Lim, John Wah;Koh, David
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.241-243
    • /
    • 2020
  • Coronavirus disease 2019 poses an occupational health risk to health-care workers. Several thousand health-care workers have already been infected, mainly in China. Preventing intra-hospital transmission of the communicable disease is therefore a priority. Based on the Systems Engineering Initiative for Patient Safety model, the strategies and measures to protect health-care workers in an acute tertiary hospital are described along the domains of work task, technologies and tools, work environmental factors, and organizational conditions. The principle of zero occupational infection remains an achievable goal that all health-care systems need to strive for in the face of a potential pandemic.