• 제목/요약/키워드: Transmission Zero

검색결과 330건 처리시간 0.029초

무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구 (A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable)

  • 김영한;최종혁;윤기섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

Research on Discontinuous Pulse Width Modulation Algorithm for Single-phase Voltage Source Rectifier

  • Yang, Xi-Jun;Qu, Hao;Tang, Hou-Jun;Yao, Chen;Zhang, Ning-Yun;Blaabjerg, Frede
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.433-445
    • /
    • 2014
  • Single phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). As the fundamental part of large scale PECs, single-phase VSC has a wide range of applications. In the paper, as first, on the basis of the concept of the discontinuous pulse-width modulation (DPWM) for three-phase VSC, a new DPWM of single-phase VSR is presented by means of zero-sequence component injection. Then, the transformation from stationary frame (abc) to rotating frame (dq) is designed after reconstructing the other orthogonal current by means of one order all-pass filter. Finally, the presented DPWM based single-phase VSR is established analyzed and simulated by means of MATLAB/SIMULINK. In addition, the DPWMs presented by D. Grahame Holmes and Thomas Lipo are discussed and simulated in brief. Obviously, the presented DPWM can also be used for single-phase VSI, GCI and APF. The simulation results show the validation of the above modulation algorithm, and the DPWM based single-phase VSR has reduced power loss and increased efficiency.

가시광통신에서 플리커 완화 및 BER 성능 향상을 위한 코딩 기법에 대한 연구 (A Study on Coding Techniques for Flicker Reduction and BER Performance Improvement in Visible Light Communication)

  • 이규진
    • 융합정보논문지
    • /
    • 제11권2호
    • /
    • pp.25-30
    • /
    • 2021
  • 본 논문에서는 가시광 통신시스템에서 플리커 완화 및 BER 성능 향상을 위한 코딩 기법에 관해서 연구하였다. 가시광 통신의 전송 속도를 높이기 위해 다수의 LED를 사용하는 멀티전송 다중 LED 전송시스템이 활발히 연구되고 있다. 그러나 N개의 LED를 사용하는 다중 LED 가시광 통신시스템에서 N개의 LED를 통해 데이터를 전송할 때, 데이터 시퀀스에 따라 동시에 0이 전송되는 연집 Zero 구간이 발생하고, 또한 1의 전송 구간이 서로 다르기 때문에 플리커 현상과 Dimming level의 변화로 인한 조명 성능 저하 현상이 발생하게 된다. 가시광 통신시스템은 통신 및 조명 기능을 동시에 수행하는 통신시스템이다. 따라서 통신의 전송 효율과 조명의 밝기를 동시에 고려되어야 한다. 우리는 이러한 문제를 해결하기 위해 각각의 LED 데이터 시퀀스의 코딩 맵핑을 통해 플리커 현상과 Dimming level 문제를 완화하고 에러 검출 및 BER 성능을 향상시킬 수 있는 플리커 완화 기법을 제안하였다.

대용량 데이터의 전송 효율 및 기록 성능 향상을 위한 Zero Copy 기술 적용에 관한 연구 (A Study on the Application of Zero Copy Technology to Improve the Transmission Efficiency and Recording Performance of Massive Data)

  • 송민규;김효령;강용우;제도흥;위석오;이성모;김승래
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1133-1144
    • /
    • 2021
  • Zero-copy는 메모리 무복사로도 불리는 기술로서 이에 대한 사용을 통해 사용자 영역과 커널 영역 간 컨텍스트 스위칭을 줄여 CPU의 부하를 최소화할 수 있다. 하지만 이 기술은 소규모의 랜덤한 파일을 전송하는 용도에 그치고, 대용량 파일 전송에는 아직 널리 활용되지 못하고 있다. 본 논문은 네트워크를 경유한 대용량 파일 처리에 있어서 Zero-copy의 실질적인 적용 방안에 대해 논의하고자 한다. 이를 위해 먼저 Zero-copy 기반으로 데이터를 전송, 저장할 수 있는 소규모 테스트베드 구축 및 프로그램을 개발하였다. 이후 세부 성능 평가를 통해 적용된 기술의 유용성을 세부 검증하고자 한다.

쥐의 신경세포 배양에 의한 수초 발생과 sindbis 바이러스 감염에 의한 수초 억제 (Generation of myelination with neural cell cultures in rats and suppression of myelination by infection of sindbis virus)

  • 사영희;김현주;이배환;홍성갑
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.528-532
    • /
    • 2019
  • 본 연구는 뉴런 세포와 슈반 세포의 공동 배양에 의한 수초화 발생 과정과 herpes simplex virus-1 감염에 의한 탈수초화 발생과정을 전자 현미경과 분자생물학적 분석에 의하여 확인하고자 하였다. 쥐의 배아로부터 후근신경절(dorsal root ganglion, DRG)을 분리하여 슈반(Schwann) 세포와 뉴런 세포(neuronal cell)를 in vitro에서 각각 배양하였다. 유사 분열 억제인자로 처리한 뉴런세포와 정제된 슈반 세포를 함께 공동 배양을 하여 수초화를 발생시켰다. 이렇게 수초화된 공동 배양 세포에 herpes simplex virus-1를 감염시켜 탈수초화를 진행시켰다. 수초 형성의 존재를 의미하는 myelin protein zero(MPZ) 항체를 사용하고 전자 현미경을 이용하여 수초 발생 및 탈수초화 과정을 관찰하였다. 이 연구는 과학 기술부, ICT 및 미래 계획 (NRF-2016R1A2B4016552 및 2017R1A2B3005753)이 자금을 지원하는 국립 연구 재단 (NRF)을 통한 기초 연구 프로그램의 지원을 받았다.

  • PDF

초전도 코일을 적용한 WPT 특성 (Characteristics of Wireless Power Transmission applying the superconducting coil)

  • 정인성;최효상
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.762-766
    • /
    • 2013
  • Interest in Wireless Power Transmission (WPT) technology has been increasing worldwide recently. This trend is proved by commercialized products such as electric toothbrush, wireless razor, and wireless charger for mobile phone battery. Studies for enhancing the applicability of the technology have been continuously conducted. Currently the WPT technology is based on the technologies using microwave, inductively coupling, and magnetic resonance. In the meantime, development of the microwave-based WPT faces difficulty due to health hazards involved in the technology, and application of the WPT technology using inductively coupling is restricted by area due to the problem of transmission length. In comparison, the WPT technology using magnetic resonance draws attention in terms of efficiency and transmission length. In this study, the sending coil based on the WPT technology using magnetic resonance system was replaced with an HTS coil to enhance transmission efficiency. Since the HTS coil has a zero resistance, power transmission loss can be minimized. At the same time, size of the current density could be increased to 100 times or more than typical coils. In addition, through impedance matching of LC device, maximal resonance properties were induced and consequently, frequency selection quality characteristics or Q was enhanced. As a result, the WPT type using the HTS coil showed a longer transmission length and better transmission efficiency compared with the WPT type using typical coils.

손실을 갖는 테이퍼 전송선로의 합성 (Synthesis of lossy tapered transmission line)

  • Park, Eui-Joon
    • 전자공학회논문지A
    • /
    • 제32A권8호
    • /
    • pp.56-63
    • /
    • 1995
  • A new method is presented for the synthesis of lossy tapered transmission line having presecribed frequency characteristic in the passband. The theory of lossy case extends lossless cases suggested by Klopfenstein and others, and a special optimization process based on the Fourier transfrom pair and generalized Taylor's procedure is proposed for exact designs of frequency-dependent and distance-dependent lossy tapered line. The process is achieved by control of zero points of lobe-like input reflection coefficient. The validity of the suggested method is confirmed by synthesizing a lossy microstrip transformer and analyzing the simulation results.

  • PDF

1회선 분기점을 갖는 병행 2회선 송전선로의 고장점 표정 알고리즘 (Fault Location Algorithm for Parallel Transmission Line with a Teed Circuit)

  • 권태원;강상희;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.116-118
    • /
    • 1999
  • A fault location algorithm that is suitable for parallel transmission line which contains a teed circuit is presented. The method uses only the local end voltage and current signals. Zero sequence currents of other lines are calculated by distribution factors, and distance equations are solved by recursive calculation.

  • PDF

한계 제로 네트워크: 한계 없는 네트워크를 위한 초연결 포토닉스 기술 동향 (Limit-Zero Network: Trends of Hyper-Connected Photonics Technology for Limitless Network)

  • 김광준;박혁;정환석;조승현;이정찬;송종태;장순혁;이준기
    • 전자통신동향분석
    • /
    • 제34권1호
    • /
    • pp.49-60
    • /
    • 2019
  • The prosperity of modern society is heavily depending on communication technology. Communication is now expanding its roles from personal convenience to social/industrial functioning. Photonics was first introduced to communication in longdistance transmission area since it provided wide bandwidth cost-effectively. However, nowadays, photonics is not only a harmonious collaborator with electronics, but has its own exclusive playgrounds in various parts of communication. Limit-zero network pursues a network that can provide abundant capacity and efficiency using very limited resources. Photonics is the most promising candidate to accomplish the goal. In this article, we review the current status and predict the future contributions of photonics to limit-zero network.

Design Considerations of Asymmetric Half-Bridge for Capacitive Wireless Power Transmission

  • Truong, Chanh Tin;Choi, Sung-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.139-141
    • /
    • 2019
  • Capacitive power transfer has an advantage in the simplicity of the energy link structure. So, the conventional phase -shift full bridge sometime is not always the best choice because of its complexity and high cost. On the other hand, the link capacitance is usually very low and requires high-frequency operation, but, the series resonant converter loses zero-voltage switching feature in the light load condition, which makes the switching loss high especially in CPT system. The paper proposes a new low-cost topology based on asymmetric half-bridge to achieve simplicity as well as wide zero voltage switching range. The design procedure is presented, and circuit operations are analyzed and verified by simulation.

  • PDF