지중송전선로의 대칭분 임피던스 모델링에 관한 연구 (A Study on the Sequence Impedance Modeling of Underground Transmission Systems)

  • 황영록;김경철
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.60-67
    • /
    • 2014
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. The majority of fault in transmission lines is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and ground wires in overhead transmission systems and through cable sheaths and earth in underground transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, EMTP-based sequence impedance calculation method was described and applied to 345kV cable transmission systems. Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

실계통 345kV 지중송전선 대칭좌표 임피던스의 해석 (Analysis of Sequence Impedances of 345kV Cable Transmission Systems)

  • 최종기;안용호;윤용범;오세일;곽양호;이명희
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

0도 CRLH 전송선로를 이용한 전력 분배기 (Power Divider using Zero-Degree Composite Right/Left-Handed Transmission Line)

  • 김승환;김영;윤영철
    • 한국항행학회논문지
    • /
    • 제13권5호
    • /
    • pp.720-725
    • /
    • 2009
  • 본 논문은 월킨슨 전력 분배기에서 고립 특성을 확보하기 위해 사용된 100오옴의 연결을 0도 CRLH 전송선로를 사용한 변형된 전력 분배기를 제안하였다. 여기서 사용된 0도 CRLH 전송선로는 위상이 음의 특성을 갖는 RH(Right-Handed) 전송선로와 양의 특성을 가지는 LH (Left-Handed) 전송선로의 결합하여 전체 전기적 길이가 0도가 되는 특성을 갖고 있다. 0도 CRLH 전송선로를 $-30^{\circ}$의 RH 전송선로와 $+30^{\circ}$의 LH 전송선로의 전기적 길이를 선택하여 2-way 전력분배기의 특성을 확인한 결과는 중심주파수 1GHz에서 -3.3dB의 S21과 -27.5dB의 S11 그리고 -25dB 이상의 S23특성을 얻었다. 이 특성은 기존의 RH 전송선로를 이용한 것과 동일함을 확인하였다.

  • PDF

Synthesis of a Complex $R^1CR$ filter with finite transmission zeros

  • Kikuchi, Hidehiro;Ishibashi, Yukio
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1863-1866
    • /
    • 2002
  • This paper describes synthesis of a complex R$^{i}$ CR filter with a finite transmission zero except zero frequency. First, a new kernel function is proposed. Secondly, how to determine the element values included in the R$^{i}$ CR filter is described. A fifth-order R$^{i}$ CR filter is designed. Finally, the sensitivity property of the proposed filter is evaluated through computer simulation.

  • PDF

A Simple Structure of Zero-Voltage Switching (ZVS) and Zero-Current Switching (ZCS) Buck Converter with Coupled Inductor

  • Wei, Xinxin;Luo, Ciyong;Nan, Hang;Wang, Yinghao
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1480-1488
    • /
    • 2015
  • In this paper, a revolutionary buck converter is proposed with soft-switching technology, which is realized by a coupled inductor. Both zero-voltage switching (ZVS) of main switch and zero-current switching (ZCS) of freewheeling diode are achieved at turn on and turn off without using any auxiliary circuits by the resonance between the parasitic capacitor and the coupled inductor. Furthermore, the peak voltages of the main switch and the peak current of the freewheeling diode are significantly reduced by the coupled inductor. As a result, the proposed converter has the advantages of simple circuit, convenient control, low consumption and so on. The detailed operation principles and steady-state analysis of the proposed ZVS-ZCS buck converter are presented, and detailed power loss analysis and some simulation results are also included. Finally, experimental results based on a 200-W prototype are provided to verify the theory and design of the proposed converter.

지중 송전선로 대칭분 임피던스 해석을 위한 EMTP 전후처리기 개발과 활용 (Development and Application of Pre/Post-processor to EMTP for Sequence Impedance Analysis of Underground Transmission Cables)

  • 최종기;장병태;안용호;최상규;이명희
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1364-1370
    • /
    • 2014
  • Power system fault analysis has been based on symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. Obtaining accurate line impedances as possible are very important for estimating fault current magnitude and setting distance relay accurately. Especially, accurate calculation of zero sequence impedance is important because most of transmission line faults are line-to-ground faults, not balanced three-phase fault. Since KEPCO has started measuring of transmission line impedance at 2005, it has been revealed that the measured and calculated line impedances are well agreed within reasonable accuracy. In case of underground transmission lines, however, large discrepancies in zero sequence impedance were observed occasionally. Since zero sequence impedance is an important input data for distance relay to locate faulted point correctly, it is urgently required to analyze, detect and consider countermeasures to the source of these discrepancies. In this paper, development of pre/post processor to ATP (Alternative Transient Program) version of EMTP (Electro-Magnetic Transient Program) for sequence impedance calculation was described. With the developed processor ATP-cable, effects of ground resistance and ECC (Earth Continuity Conductor) on sequence impedance were analyzed.

전류분배계수를 사용하는 병행 2회선 송전선로 고장점 표정 알고리즘 (Current Distribution Factor Based Fault Location Algorithms for Double-circuit Transmission Lines)

  • 안용진;강상희;최면송;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.146-152
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on sequence current distribution factors for a double-circuit transmission system. The proposed method uses the voltage and current collected at only the local end of a single-circuit. This method is virtually independent of the fault resistance and the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit and insensitive to the variation of source impedance. The fault distance is determined by solving the forth-order KVL(Kirchhoff's Voltage Law) based distance equation. The zero-sequence current of adjacent circuit is estimated by using a zero-sequence current distribution factor and the zero-sequence current of the self-circuit. Thousands of fault simulation by EMTP have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구 (A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI))

  • 박재흥;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

DESIGN AND CONSTRUCTION ASPECTS OF A ZERO INERTIA CVT FOR PASSENGER CARS

  • Van Druten, R.M.;Van Tilborg, P.G.;Rosielle, P.C.J.N.;Schouten, M.J.W.
    • International Journal of Automotive Technology
    • /
    • 제1권1호
    • /
    • pp.42-47
    • /
    • 2000
  • This paper concentrates on the design and construction aspects of a transmission for a mid-class passenger car with internal combustion engine. The transmission, consisting of a Continuously Variable Transmission (CVT) with a Van Doorne V-belt, a planetary gear set and a compact steel flywheel is used to prove the concept of mechanical torque assist. The design goal is to obtain a proof of concept transmission with maximal efficiency, using proven transmission technology. With the developed so called Zero Inertia CVT, the fuel economy of the car is improved by operating the engine at its fuel optimal operating line. To achieve a good vehicle acceleration response, the flywheel assists the powertrain mechanically.

  • PDF

A Method for Improving Stopband Characteristics of a Dual-Band Filter

  • Lee, Ja-Hyeon;Lim, Yeong-Seog
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.186-191
    • /
    • 2011
  • This paper presents a simple and effective method for improving stopband rejection characteristics of previously studied dual-band filters. Small electric couplings were applied to the symmetrically positioned shunt resonators, which divided each transmission zero into two transmission zeros without any effect on passbands. We were able to achieve improved stopband rejection characteristics by these additional transmission zeros. For the filter application, we designed a dual-band filter with improved stopband characteristics using microstrip quasi-lumped elements. The electric couplings that control the location of transmission zeros are controlled by the distance between symmetric open stubs of the filter. The filter was fabricated with a relative dielectric constant of 3.5 and a thickness of 0.76 mm. The fabricated filter has a small size ($14.6{\times}13.2{\times}0.76$ mm) and a low insertion loss when compared with conventional filters.