• Title/Summary/Keyword: Transmission Right

Search Result 267, Processing Time 0.024 seconds

Resonance Frequency and Bandwidth of the Negative/Positive nth Mode of a Composite Right-/Left-Handed Transmission Line

  • Kim, Seong-Jung;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • In this study, the analytic expression for the positive/negative $n^{th}-Mode$ resonance frequency of an N unit cell composite right-/lefthanded (CRLH) transmission line is derived. To explain the resonance mechanism of the $n^{th}$ mode, especially for the negative mode, the current distribution of the N unit cell CRLH transmission line is investigated with a circuit simulation. Results show that both positive and negative $n^{th}$ resonance modes have n times current variations, but their phase difference is $180^{\circ}$ as expected. Moreover, the positive $n^{th}$ resonance occurs at a high frequency, whereas the negative $n^{th}$ resonance transpires at a low frequency, thus indicating that the negative resonance mode can be utilized for a small resonator. The correlation between the slope of the dispersion curve and the bandwidth is also observed. In sum, the balanced condition of the CRLH transmission line provides a broader bandwidth than the unbalanced condition.

A Basic Study on Efficient Acrylic Plate Light Transmission Road Machining (효율적인 아크릴판 광전송로 가공에 관한 기초 연구)

  • Han, Su-Won;Hong, Jun-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.1
    • /
    • pp.95-101
    • /
    • 2022
  • This paper proposes a method to process the shape of an optical transmission road and attempts to determine the most suitable single processing method for an acrylic plate optical transmission road. In addition, by manufacturing an automatic pattern processing device to generate certain shapes on the acrylic plate at regular intervals, and measuring the illuminance of the patterned acrylic plate optical transmission road, the measured illuminance was confirmed to fall under the KS illuminance values presented in Table 1. In conclusion, when an incident light of approximately 20,000 lx is applied, the transmission illumination is approximately 200 lx, which represents a transmission rate of approximately 1% for incident light and corresponds to the KS illumination criterion F. Additionally, the right-angle triangular pyramid base size (A) processed at a temperature of 350 ℃ for one second was 2 mm, exhibiting the largest transmission illumination of 280 lx. When the transparent acrylic plate was set to a constant size of 1.6 mm at the bottom of the right-angle triangular pyramid, the fastest response occurred at a processing tip temperature of 350 ℃ (0.04 s). On the other hand, it took 10 s to process the size of the bottom of the right-angled triangular pyramid at a temperature of 200 ℃ to 1.6 mm, and it was confirmed that the optical transmission efficiency was significantly reduced because of the burr that occurred at this time.

Analysis and Design of Low Pass Filter using Unit Cell based on CRLH Transmission Line

  • Yang, Lei;Yang, Doo-Yeong
    • International Journal of Contents
    • /
    • v.8 no.3
    • /
    • pp.100-104
    • /
    • 2012
  • In this paper, a unit cell for low pass filter design by using composite right and left-handed transmission line in conductor-backed coplanar waveguide is proposed. The characteristics of the unit cell are analyzed in order to design a low pass filter in small sizes. By changing the sizes of the unit cell, the parameters of right-handed and left-handed immittance components are changed and the desired characteristics of the unit cell are achieved. The equivalent circuit of the unit cell is extracted and analyzed either. As a result, the simulation results of the unit cell and the equivalent circuit are almost identified. The movement and energy distributions of electromagnetic field are shown to confirm the property of the unit cell. In the end, a low pass filter is demonstrated by cascading three proposed unit cells, which shows cutoff frequency of 1.53GHz and deep attenuation from 2.23GHz to 4.49GHz lower than -50dB.

A Study on the Environmental Effects of Compact Tower in Transmission Line (송전철탑 Compact화에 따른 전기환경 영향 연구)

  • Lee, Jung-Won;Lee, Won-Kyo;Lee, Dong-Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.645-650
    • /
    • 2010
  • The continuous increase demand for electric power leads to the additional construction of transmission facilities, but it is not easy to acquire right-of-way for transmission facilities. Therefor, there is a need for compact tower that can be built on a narrow right-of-way the compact tower with polymer insulation arm is a solution. It can be upgrading conventional 154 kV transmission line voltages to 345 kV levels. However transmission voltage is increasing, environment interference (corona noise, radio interference, etc.) will occur gradually. This environment interference is depending on the electrical clearances of tower and configuration of conductors. Therefore the analysis of the factors of environmental interference is necessary in order to upgrading transmission voltage. This paper presents the design factor of a compact tower to meet the environmental interference standard.

A Study on the Effective Guarantee of the Right to Portability of Personal Health Information (개인건강정보 이동권의 실효적 보장에 관한 연구)

  • Kim, Kang Han;Lee, Jung Hyun
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.2
    • /
    • pp.35-77
    • /
    • 2023
  • As the amendment to the Personal Information Protection Act, which newly established the basis for the right to request transmission of personal information, was promulgated through the plenary session of the National Assembly, MyData, which was previously applied only to the financial sector, could spread to all fields. The right to request transmission of personal information is the right of the information subject to be guaranteed for the realization of MyData. However, since the right to request transmission of personal information stipulated in the Personal Information Protection Act is designed to be applied to all fields, not a special field such as the medical field, it has many shortcomings to act as a core basis for implementing MyData in Medicine. Based on this awareness of the problem, this paper compares and analyzes major legal trends related to the right to portability of personal health information at home and abroad, and examines the limitations of Korea's Personal Information Protection Act and Medical Act in realizing Medical MyData. Under the Personal Information Protection Act, the right to request transmission of personal information is insufficient to apply to the medical field, such as the scope of information to be transmitted, the transmission method, and the scope of the person obligated to perform the transmission, etc.. Regulations on the right to access medical information and transmission of medical records under the Medical Act also have limitations in implementing the full function of Medical My Data in that the target information and the leading institution are very limited. In order to overcome these limitations, this paper prepared a separate and independent special law to regulate matters related to the use and protection of personal health information as a measure to improve the legal system that can effectively guarantee the right to portability of personal health information, taking into account the specificity of the medical field. It was proposed to specifically regulate the contents of the movement and transmission system of personal health information.

Composite Right/Left Handed(CRLH) Transmission Line with Controllable Transmission Zeros (제어 가능한 전송 영점을 갖는 CRLH 전송 선로)

  • Lee, Ja-Hyeon;Kim, Kyoung-Keun;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.583-590
    • /
    • 2010
  • In this paper, a novel CRLH-TL unit cell with controllable transmission zeros was proposed. Proposed composite right/left handed transmission line(CRLH-TL) unit cell is implemented in the form of the metal-insulator-metal(MIM) capacitors, the microstrip stub inductors, and the co-planar waveguide(CPW) inductor. And this proposed CRLH-TL generates two transmission zeros in lower/upper passband by the effort of electromagnetic couplings between each MIM capacitors and microstrip stub inductors. Using this proposed CRLH-TL, broad bandpass filter for UWB system was designed and fabricated. The measured results reveal that the two transmission zeros are observed in lower/upper passband and the overall size of the filter, excluding the feed line is about 8 mm$\times$8 mm, less then $\lambda_g$/4 on electric size.

Linearity and Efficiency Improved outphasing Class-E Power Amplifier Using Composite Right/Left-Handed Transmission Lines Combiner (Composite Right/Left-Handed Transmission Lines 결합기를 이용하여 선형성과 효율을 향상한 outphasing E급 전력 증폭기)

  • Eun, Sang-Ki;Cho, Choon-Sik;Lee, Jae-W.;Kim, Jae-Heung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1313-1321
    • /
    • 2008
  • outphasing class-E power amplifier using composite right/left-handed transmission lines(CRLH-TL) is proposed at 2.4 GHz. The power combiner including CRLH-TL is designed to suppress the second and third harmonics to increase linearity and the output problem of the conventional outphasing amplifier is also solved by the proposed outphasing amplifier. So the P AE is improved. The measured maximum output power at the fundamental frequency shows 31.8 dBm, whereas the PAE shows 50 % with 14 dBm input power excited. The IMD3 is improved by 5 dB compared to that of conventional outphasing amplifier.

Fluidically-Controlled Phase Tunable Line Using Inkjet-Printed Microfluidic Composite Right/Left Handed Transmission Line (유체를 이용하여 위상응답을 제어하기 위해 잉크젯 프린팅으로 구현한 미세유체채널 복합 좌·우향 전송선로)

  • Choi, Sungjin;Lim, Sungjoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • In this paper, a novel fluid controlled phase tunable line using inkjet printed microfluidic composite right/left-handed(CRLH) transmission line(TL) is proposed. A CRLH-TL prototype has been inkjet-printed on a paper substrate using silver nano particle ink. In addition, a laser-etched microfluidic channel in poly methyl methacrylate(PMMA) has been integrated with the CRLH TL using inkjet-printed SU-8 as a bonding material. The proposed TL provides excellent phase-tuning capability that is dependent on the different fluidic materials used. As the fluid is changed, the proposed TL can have negative-phase, zero-phase, and positive-phase characteristics at 900 MHz and reflection coefficient is maintained to below -10 dB. The performance of the proposed TL is successfully validated using simulation and measurement results.

Dual-Mode Balanced Filter in Symmetric Composite Right/Left-Handed Transmission Line Structure (CRLH 전송선로 대칭구조의 이중모드 평형 필터)

  • Kim, Young;Sim, Seok-Hyun;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.2
    • /
    • pp.196-201
    • /
    • 2013
  • In this paper, a dual-mode balanced filter with symmetric coupled composite right/left-handed transmission line is introduced. Unlike the other symmetric structure, this configuration has the ability to operate under both common- and differential-mode excitation. These properties are achievable through providing physical short circuit by means of ground vias at the center of each unit-cell along the symmetry plane of the structure. Because the CRLH unit-cells are operated under both common- and differential-mode excitation, we implemented a balanced filter using these properties. To validity these features, a five-cell four port coupled CRLH-TL is simulated, fabricated and measured and the obtained performances agree with the simulation results under both common- and differential-mode excitation.

A Broadband Half-Mode Substrate Integrated Waveguide Quadrature Wilkinson Power Divider Using Composite Right/Left-Handed Transmission Line

  • Eom, Dong-Sik;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2017
  • In this work, a broadband composite right/left-handed (CRLH) half-mode substrate integrated waveguide (HMSIW) quadrature Wilkinson power divider is proposed. The proposed CRLH-HMSIW quadrature power divider includes a microstrip Wilkinson power divider on the transition structure between the microstrip and HMSIW, and two thru transmission lines for the HMSIW and the CRLH-HMSIW. The measured amplitude, phase difference and isolation between the two output ports of the proposed structure have 1 dB, ${\pm}5^{\circ}$ and less than -15 dB in a wide frequency range of 4.1-6.68 GHz with 47.9% bandwidth, respectively.