• 제목/요약/키워드: Transmission Oil

검색결과 240건 처리시간 0.03초

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

자동변속기 오일 소요유량 시험법개발 및 측정데이터 분석 (Development of the Oil Consumption Rate Test Method and Measurement Data Analysis for an Automatic Transmission System)

  • 정헌술;오석형;이재신;임진승
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.10-16
    • /
    • 2009
  • Automatic power transmission systems consisted of a torque converter and several planetary gear sets, clutches and brakes are controlled by a hydraulic shift control circuit and an electronic transmission control unit. The hydraulic circuit serves for the operation of the torque converter and lubrication oil supply of the transmission system as well as for the actuation of clutches for the automatic gear shift. The complicated hydraulic control circuit constructed by many spools, solenoids, orifices and flow passages are integrated into one small valve block and it is powered by one hydraulic pump. In this paper, a test equipment was developed to measure the oil consumption of each component at various wide operating conditions. Test data about 730 sets acquired from five test items are analyzed and discussed on the oil capacity of the circuit.

  • PDF

Two Factors Failure Model of Oil-Paper Insulation Aging under Electrical and Thermal Multistress

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.957-963
    • /
    • 2014
  • Converter transformers play important roles in high-voltage direct current transmission systems. This paper presents experimental and analysis results of the combined electrical and thermal aging of oil-impregnated paper at pulsating DC voltages. Breakdown voltages and time-to-breakdown of oil-paper specimens were measured by using short-time and constant-stress tests. The breakdown characteristics of combined electrical and thermal aging on insulation system were discussed. According to the relationship between failure time and aging temperature, the two-parameter Weibull model was improved. On the basis of the competing risk algorithm and the improved Weibull model, the two factors failure model was calculated. And the influence of temperature in the insulation system has been analyzed. This model performs better than the two-parameter Weibull model when both time and temperature are considered as variables in estimating the lifetime of oil-paper insulation.

병렬구조 TSK 퍼지 모델을 이용한 선박용 기름배출 감시장치의 실시간 기름농도 예측모델 (On-line Prediction Model of Oil Content in Oil Discharge Monitoring Equipment Using Parallel TSK Fuzzy Modeling)

  • 백경동;조재우;최문호;김성신
    • 제어로봇시스템학회논문지
    • /
    • 제16권1호
    • /
    • pp.12-17
    • /
    • 2010
  • The oil tanker ship over 150GRT must equip oil content meter which satisfy requirements of revised MARPOL 73/78. Online measurement of oil content in complex samples is required to have fast response, continuous measurement, and satisfaction of ${\pm}10ppm$ or ${\pm}10%$ error in this field. The research of this paper is to develop oil content measurement system using analysis of light transmission and scattering among turbidity measurement methods. Light transmission and scattering are analytical methods commonly used in instrumentation for online turbidity measurement of oil in water. Gasoline is experimented as a sample and the oil content approximately ranged from 14ppm to 600ppm. TSK Fuzzy Model may be suitable to associate variously derived spectral signals with specific content of oil having various interfering factors. Proposed Parallel TSK Fuzzy Model is reasonably used to classify oil content in comparison with other models. Those measurement methods would be effectively applied and commercialized to oil content meter that is key components of oil discharge monitoring control equipment.

윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구 (An Experimental Study on the Light Transmission Characteristics with Oil Contamination)

  • 조성용;장철주;공호성;윤의성;한흥구
    • Tribology and Lubricants
    • /
    • 제17권6호
    • /
    • pp.482-489
    • /
    • 2001
  • Changes in light transmission characteristics caused by various types of oil contaminations were experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon duct, two kinds of solutions and grease were used for the test contaminants in this work. Light intensity of the transmitted light was measured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and poly-meric fibers in terms of the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change in lubricating oils.

윤활유 오염에 따른 광투과율 변화에 관한 실험적 연구 (An Experimental Study on the Light Transmission Characteristics with Oil Contamination)

  • 조성용;장철주;공호성;윤의성;한흥구
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.287-298
    • /
    • 2001
  • Change in light transmission characteristics caused by various types of oil contaminations was experimentally measured with a built-in type wear monitoring device. Three kinds of iron powders of different size distribution, carbon dust, two kinds of solutions and grease were used for the lest contaminants in this work. Light intensity of the transmitted light was treasured with the contamination level. Results showed that the transmitted light intensity decreased linearly with the contamination concentration in the oil and the slope was affected by the size distribution. Light attenuation was also caused greatly by carbon dust, water contamination and polymeric fibers mainly due to the light absorption. As a result, it was proved that the optical measurement device could be applicable effectively for detecting any significant change iii lubricating oils.

  • PDF

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

유체커플링의 작동유체량의 변화에 대한 토크와 회전수 특성에 관한연구 (A Study on the characteristics Torque and rpm for Varying Oil Quantity in Hydaultic Couplings)

  • 박용호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.241-247
    • /
    • 1998
  • The hydraulic coupling is a kind of power transmission device combined with pump turbine and casing as its main parts. The purpose of this research is to construct an experimental test set-up and to establish an available soft ware for th characteristics of two domestically developed hydraulic couplings. The test item is torgue rpm. and slip and or efficiency characteristic in accordance with variation of oil quantity. in this case the oil quantity was varied 55%, 67% and 77% of the inside capacity of hydraulic copuling.

  • PDF

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.