• Title/Summary/Keyword: Transmission Line Method

Search Result 1,066, Processing Time 0.027 seconds

Analysis of the influence of magnetic field generated from power transmission on the inductance interference (송전선에서 발생되는 자계에 의한 유도장해 해석)

  • Choi, Se-Yong;Nah, Wan-Soo;Choi, Myung-Jun;Lee, Se-Hee;Kim, Dong-Su;Park, Il-Han;Shin, Myung-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1993-1995
    • /
    • 2000
  • In this paper, we calculate the magnetic field and analyze the inductive interference in conductive material around power transmission line. To compute induced eddy currents as well as magnetic fields, finite element method(FEM) is used for numerical calculation. The characteristics, transmission line height, conductive earth and mitigation wire are taken account of FEM analysis. This research also shows that mitigation wire reduces amount of eddy current in buried pipe line.

  • PDF

A Robust Algorithm for On-line Economic Dispatch (온라인 발전계획을 위한 강건한 경제급전 알고리즘)

  • Song, Kyung-Bin;Han, Seung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1111-1113
    • /
    • 1998
  • A robust economic dispatch algorithm involving transmission losses is proposed and investigated for a possibility of on-line applications. In this paper, the penalty factors are calculated directly from transposed Jacobian of load flow analysis with advantages of superiority to B-coefficients method based on its computation time and suitability for real time application since the approach is based on a current system condition. The proposed algorithm is systematically handling the generation capacity constraints with transmission losses. Implementation of the algorithm for IEEE systems and EPRI Scenario systems shows that computation time is enough to apply on-line economic dispatch to large power system and production cost is saved compared with the crude classical economic dispatch algorithm without considering transmission losses.

  • PDF

The Design and Aging Test of Polymer Insulator for Power Transmission and Distribution (송배전용 고분자 애자의 설계와 열화시험)

  • Lee, Un-Yong;Cho, Han-Gu;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.553-555
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. In this paper, the design trend and method polymer insulator are investigated and Aging test method is analysed to know life time of insulator.

  • PDF

Calculation of characteristic Impedance of the U-Type Transmission Line by the Moment Method (모먼트법에 의한 U형 부송선의 특성임피던스 계산)

  • 이상설
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.1
    • /
    • pp.29-34
    • /
    • 1982
  • We can find the characteristic impedances of the U-type transmission lines by finite d ifference method. In this paper, the characteristic impedances of the lines are computed by the moment method. There are 10% differences between the results of the finite difference method and those of the moment method. But when the interior conductor of the line is located at the center of the exterior conductor, the results of the moment method approache to that of analytical result when the length of outer conductor becomes in finite.

  • PDF

A study of optimal data transmission modem for control system using Power-distribution circuit (전력선 버스를 이용한 제어시스템의 최적통신모뎀에 관한 연구)

  • Chung, Chang-Kyung;Park, Young-Chull;Son, Dong-Sub;Kang, Jeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.496-498
    • /
    • 1995
  • A power line data transmission method has been developed and presented in this paper. Although there have been efforts to develope power line data transmission techniques, none of them has been accepted as a standard. Thus, our method follows a defacto standard CENELEC's recommendations. The paper presents the algorithm as well as experimental results.

  • PDF

A Protection Method with single-bonding system in EHV Underground Transmission Line (초고압 지중 케이블 시스템에 대한 편단접지시의 보호대책)

  • Kim, J.W.;Kang, D.H.;Park, K.R.;Kim, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1620-1622
    • /
    • 1998
  • The failure occurs in the system of the underground transmission line, the time of restoration is very long, the damage from stopping power supply is very serious and the cost of restoration is very great. because of these problems, the system and equipment must be protected from every electrical failure by installing protection unit. This study is summarized and compared the effects of configuration method of cable protection device with respect to surges in EHV (Extra High Voltage) underground transmission system.

  • PDF

Chaos Secure Communication with Lossless Transmission Line of Chaos Circuit (무손실 전송선로를 가진 카오스 회로에서의 카오스 비밀통신)

  • 배영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.505-508
    • /
    • 1999
  • Chua's circuit is a simple electronic network which exhibits a variety of bifurcati ell and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed and a secure communications of lossless transmission line are investigated. A secure communication method in which tile desired information signal is synthesized with the chaos signal created by the Chua's circuit is proposed and information signal is demodulated also using the Chua's circuit. Tile proposed method is synthesizing tile desired information with the chaos circuit by adding the information signal to the chaos signal in the lossless transmission system.

  • PDF

Evaluation for Lifetime and Thermal Ratings for Aged Overhead Transmission Lines (노후 가공송전선의 수명과 열용량의 평가)

  • Kim, Sung-Duck
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Thermal rating or lifetime evaluation for aged overhead transmission line becomes more important concerns with respect to keeping power delivery stable having proper capability. Both load rating and dip/clearance are essential factors to determine transmission capacity. In order to evaluate thermal rating and conductor lifetime for domestic transmission lines with double-circuit, the dip/ground clearance standards as well as the electrical equipment technical standard are examined. Conductor temperature and dip are calculated under the assumption of a contingency, and then, a method to up-rate load capacity is searched. As thermal rating and limit dip for aged conductor are properly evaluated, an improved strategy in order to guarantee the existing power system reliability is presented in this paper.

Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection (X-선 투과검사를 이용한 저항 점용접부 품질평가기법)

  • Lee, Jong-Dae;Lee, So-Jeong;Bang, Jung-Hwan;Yoon, Gil-Sang;Kim, Mok-Soon;Kim, Jun-Ki
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

FDTD Analysis of Lossy Multiconductor Transmission Lines Terminated in Linear Loads (선형소자로 종단된 손실이 있는 다중 전송선의 FDTD 해석)

  • 박범준;주재철;이형영;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.3
    • /
    • pp.419-428
    • /
    • 2000
  • Multiconductor transmission line(MTL) equations are solved by FDTD(Finite-Difference Time-Domain) method to predict crosstalk and fields to transmission line coupling on lossy multiconductor transmission lines terminated in arbitrary linear loads. Skin effect losses as well as dc losses are included in the analysis. In order to increase computational efficiency, the convolution integral of internal impedance of conductors and the line currents is computed by using Prony method. For boundary conditions of MTLs terminated in linear loads, state-variable formulation is adopted. The simulated results by FDTD method are compared with the measured ones obtained by using TEM cell. The predictions are in good agreement with the measurements. In addition, it has been found that skin effect losses as well as dc losses of the conductors should be included for accurate predictions on relatively high loss transmission lines such as PCB. It has also been found that dc losses and skin-effect losses affect late-time responses and early-time responses, respectively.

  • PDF