• Title/Summary/Keyword: Transmission Line

Search Result 3,296, Processing Time 0.029 seconds

The Performance Analysis of Transmission Line Codes for the Very-High Speed Optical Transmission System. (초고속 광전송 시스템용 전송로 부호의 성능 분석)

  • Yu, Bong-Seon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.479-489
    • /
    • 1994
  • At the present time, it is an important problem that we are to select a transmission line code for the very-high speed optical transmission system which can confidentially transfer the original information signal sequence efficiently, as it is to be the large capacity and the economization for the optical digital transmission system to transfer the information signal sequence at the very-high speed. Therefore, this paper is to select first the proper transmission line codes for the high speed(more than Mb/s) optical transmission system of the proposed two-level unipolar transmission line codes up to date, and to decide a mBIZ (m Binary with One Zero insertion) code as an optimal transmission line code for the very-high speed optical transmission system, resulting from analyzing the performance at the requirements of the transmission line code, such as the maximum consecutive identical digits, the transmission delay time, the increasing rate of clock, the mark rate, the circuit complexity, the supervision of transmission line error, and power spectrum among the selected transmission line codes.

  • PDF

A study on Subspan Oscillation Analysis of 6 Bundle Conductor Transmission lines (6도체방식 송전선로의 서브스판진동 해석에 관한 연구)

  • 이형권
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.729-736
    • /
    • 1997
  • The subspan oscillation is the most important in bundled transmission lines, which can cause conductor damage and transmission line hardware failures. So it is necessary to analyze the subspan oscillation in details for transmission lines. This paper suggests the basic concept and theoretical analysis method of subspan oscillation for 6 bundle conductor transmission line, which considers wind speed, subspan length and conductor tension. Especially this paper uses a spacer damper model with clamp-arm flexibility and damping characteristics. Theoretical analysis results are proposed.

  • PDF

On the Limitation of Telegrapher′s Equations for Analysis of Nonuniform Transmission Lines

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.68-71
    • /
    • 2004
  • The limitation of telegrapher's equations for analysis of nonuniform transmission lines is investigated here. It is shown theoretically that the input impedance of a nonuniform transmission line cannot be derived uniquely from the Riccati equation only except for the exponential transmission line of a particular frequency-dependent taper. As an example, the input impedance of an angled two-plate transmission line is calculated by solving the telegrapher's equations numerically. The numerical results suffer from larger deviation from its rigorous solution as the plate angle increases.

The circuit design to be power transmission or power distribution using the dual characteristic impedance transmission line (이중 특성 임피던스 전송 선로를 이용한 전력 전송 또는 전력 분배가 가능한 회로 설계)

  • Park, Unghee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2339-2344
    • /
    • 2014
  • of a microstrip transmission line, this transmission line can operate as the microstrip line or the coplanar line according to open or short connection between the ungrounded copper plane and grounded plane on the base plane. Two different type operation of the transmission line means that one transmission line can have two different characteristic impedances. This paper proposes and fabricates the circuit to be operated 2-ports power transmission line or 2-way power divider with the stable input matching characteristic by using this dual-impedance transmission line. The proposed circuit operates 2-ports power transmission line in case of the coplanar line or 2-way power divider line in case of the microstrip line. The fabricated circuit shows $S_{21}$ > -0.2 dB and $S_{11}$ < -15 dB above 700 MHz when the circuit operates 2-ports power transmission line. And, it is $S_{21}$ > -3.8 dB, $S_{11}$ < -10 dB and $S_{21}/S_{31}$ < ${\pm}0.3dB$ above 700 MHz when the circuit operates 2-way power divider.

Symmetrical Scanning Leaky Wave Antenaa Using Double Negative and Double Positive Transmission Line (Double Negative, Positive 전승 선로를 이용한 대칭적적인 주파수 스캐닝 누설파 안테나)

  • 이재곤;이정해
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.11
    • /
    • pp.1069-1074
    • /
    • 2004
  • In this paper, we have designed artificial double negative(DNG) transmission line composed of series inter-digital capacitor and two shunt inductive short stubs. This artificial DNG transmission line has the property of double positive (DPS) transmission line over some frequency ranges due to RF nature. In detail, this transmission line simultaneously has the contrary properties of DNG and DPS transmission line depending on operation frequency. DPS/DNG transmission line at leaky region is utilized to design frequency scanning antenna with backfire-to-endfire. We have simulated and measured the dispersion and for-field radiation beam patterns of symmetrical leaky wave antenna. The results show rough agreement.

Analysis of Electric field and Ion Characteristics on HVDC Overhead Transmission Line (초고압 직류가공 송전선로에서의 전계 및 이온류 특성분석)

  • Lim, Jae-Seop;Shin, Koo-Yong;Lee, Dong-Il;Ju, Mun-No;Yang, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1638-1643
    • /
    • 2010
  • HVDC is better economic method than HVAC in case of long distance transmission and it is possible to interconnect transmission lines regardless of difference of power frequency. The electrical environment problems of HVDC overhead transmission line are electric field, charged voltage, ion current and so on. For biopolar HVDC lines, most of the ions are directed toward the opposite polarity conductor, but a significant fraction is also directed toward the ground. These problems are major factor to design configuration of HVDC overhead transmission line. Therefore, It is necessary to test an environmental characteristics of HVDC overhead transmission line. In this paper, to assess the ion characteristic of HVDC transmission line, continuous measurements have been done on the biopolar single circuit line with ACSR 480mm2-6 bundle conductors of Gochang HVDC Test line. And then the ion characteristics were analyzed.

Pressure Control of a Pneumatic Conrol system with a long Transmission Line (긴 전달관로를 갖는 공압제어계의 압력 제어)

  • Jang, Ji-Seong;Lee, Kwang-Kuk;Choi, Myung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.567-576
    • /
    • 2003
  • In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, it a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feedforward controller to regulate command fallowing performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model or the transmission line. Therefore, the designed controller can be utilized for the Performance improvement of a Pressure control system with a long transmission line using compressible fluid.

Experimental and numerical study on the collapse failure of long-span transmission tower-line systems subjected to extremely severe earthquakes

  • Tian, Li;Fu, Zhaoyang;Pan, Haiyang;Ma, Ruisheng;Liu, Yuping
    • Earthquakes and Structures
    • /
    • v.16 no.5
    • /
    • pp.513-522
    • /
    • 2019
  • A long-span transmission tower-line system is indispensable for long-distance electricity transmission across a large river or valley; hence, the failure of this system, especially the collapse of the supporting towers, has serious impacts on power grids. To ensure the safety and reliability of transmission systems, this study experimentally and numerically investigates the collapse failure of a 220 kV long-span transmission tower-line system subjected to severe earthquakes. A 1:20 scale model of a transmission tower-line system is constructed in this research, and shaking table tests are carried out. Furthermore, numerical studies are conducted in ABAQUS by using the Tian-Ma-Qu material model, the results of which are compared with the experimental findings. Good agreement is found between the experimental and numerical results, showing that the numerical simulation based on the Tian-Ma-Qu material model is able to predict the weak points and collapse process of the long-span transmission tower-line system. The failure of diagonal members at weak points constitutes the collapse-inducing factor, and the ultimate capacity and weakest segment vary with different seismic wave excitations. This research can further enrich the database for the seismic performance of long-span transmission tower-line systems.

Analysis of the Competitive Effects of Financial Transmission Rights on Electricity Markets (재무적 송전권의 전력시장에의 영향 분석)

  • 김진호;박종배;신중린
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.6
    • /
    • pp.350-357
    • /
    • 2004
  • In a deregulated electricity generation market, the sufficient capacity of transmission lines will promote the competition among generation companies (Gencos). In this paper, we show that Gencos' possession of rights to collect congestion rents may increase the competition effects of the transmission lines. In order for concrete analysis on this effect, a simple symmetric market model is introduced. In this framework, introducing the transmission right to the Gencos has the same strategic effects as increasing the line capacity of the transmission line. Moreover, the amount of effectively increased line capacity is equal to the amount of the line rights. We also show that the asymmetric share of the financial transmission rights may result in an asymmetric equilibrium even for symmetric firms and markets. We also demonstrate these aspects in equal line rights model and single firm line rights model. Finally, a numerical example is provided to show the basic idea of the proposed paper.

Electrical Characteristics Evaluation of Transmission Line Arresters (송전선로용 피뢰기의 전기적 특성 평가)

  • Kim, Seok-Sou;Heo, Jong-Cheol;Mun, In-Wook;Oh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1498-1499
    • /
    • 2006
  • It has been reported that more than 50% of breakdown in transmission line for 154kV and above is due to lightning stroke. The flashover failure due to lightning stroke causes outage, voltage drop and instantaneous outage, Therefore line arrestors have been used in transmission line for protection from lightning stroke. In this paper, we describes electrical characteristics and performance test of line arrestor for transmission line.

  • PDF