• Title/Summary/Keyword: Transmission Area

Search Result 1,872, Processing Time 0.028 seconds

Highly Simplified and Bandwidth-Efficient Human Body Communications Based on IEEE 802.15.6 WBAN Standard

  • Kang, Tae-Wook;Hwang, Jung-Hwan;Kim, Sung-Eun;Oh, Kwang-Il;Park, Hyung-Il;Lim, In-Gi;Kang, Sung-Weon
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1074-1084
    • /
    • 2016
  • This paper presents a transmission method for improving human body communications in terms of spectral efficiency, and the performances of bit-error-rate (BER) and frame synchronization, with a highly simplified structure. Compared to the conventional frequency selective digital transmission supporting IEEE standard 802.15.6 for wireless body area networks, the proposed scheme improves the spectral efficiency from 0.25 bps/Hz to 1 bps/Hz based on the 3-dB bandwidth of the transmit spectral mask, and the signal-to-noise-ratio (SNR) by 0.51 dB at a BER of $10^{-6}$ with an 87.5% reduction in the detection complexity of the length of the Hamming distance computation. The proposed preamble structure using its customized detection algorithm achieves perfect frame synchronization at the SNR of a BER of $10^{-6}$ by applying the proposed pre-processing to compensate for the distortions on the preamble signals due to the band-limit effects by transmit and receive filters.

Methodology of 22.9 ㎸ HTS Gable application for practical distribution system in metropolitan area (22.9 ㎸ 초전도 케이블의 대도심 배전계통 적용방안)

  • 윤재영;김종율;이승렬
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • As the power demand has increased, it is expected that the transmission system will have more complicated problems under the influence of investment reduction for overall power system. The route length per MW demand will be reduced gradually from 0.6[C-km/㎿] to 0.53 [C-km/㎿] in 2010. This comes up to a real serious problem of system planning and operation viewpoints HTS power technologies have properties to solve these complex transmission and distribution constraints, especially for metropolitan area, in the future. As the HTS technology has developed, the HTS cable technology can be the most effective alternative to solve the future expected transmission constraints as compared with other countermeasures in terms of economics, environments and system operation. This paper describes the general application methodology of developing 22.9 ㎸ HTS cable by CAST for practical distribution system, particularly, step-by-step application methodology of 22.9 ㎸ HTS cable to substitute the existing and planning 154 ㎸ cable. In this scheme, almost of the downtown 154 ㎸ substation of metropolitan city such as Seoul will be changed into 22,9 ㎸ switching station.

  • PDF

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

A Finite Element Analysis of the Effects of Necrotic Area on Stresses in Early Osteonecrosis of Femoral Head (대퇴 골두내 무혈성괴사 영역에 따른 응력변화 분석 -3차원 유한요소법을 이용한 분석-)

  • Kang, S.B.;Joo, W.;Kim, Y.M.;Kim, H.J.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.349-350
    • /
    • 1996
  • Using FEM, we analyzed the stress changes on early osteonecrosis of femoral head as the necrotic area increases. A 3D FEM model of proximal femur was made from the CT scam data of fresh frozen adult proximal femur with the material properties from literature. The model consisted of 5994 elements and 5275 nodes. FE analyses were peformed using MSC/NASTRAN. At normal states, stress transmission is mainly along the primary compression trabeculae(PCT). Until 60% involvement of PCT with necrotic lesion, stress transmission is still along the remained PCT. When the PCT involvement is from 60% to 85%, stress transmission is along the PCT and margin of the necrotic lesion. When involvement is more than 85%, stress is mostly transferred to posterior part of femoral head.

  • PDF

Optimization of Casting Design for Automobile Transmission Gear Housing by 3D Filling and Solidification Simulation in Local Squeeze Diecasting Process (국부가압 다이캐스팅 공정에서 3차원 유동 및 응고해석을 통한 자동차 변속기 Gear Housing의 주조방안 설계 최적화)

  • Park, Jin-Young;Kim, Eok-Soo;Park, Yong-Ho;Park, Ik-Min
    • Korean Journal of Materials Research
    • /
    • v.16 no.11
    • /
    • pp.668-675
    • /
    • 2006
  • In the partial squeeze casting process, the filling behavior of liquid metal and solidification pattern in thick area have significant influence on the quality of casting products and die life. For the optimal casting design of automobile transmission gear housing, various analyses were performed in this study by using computer simulation code, MAGMAsoft and the simulation results were compared and analyzed with experimental results. By air pressure criteria, internal porosities caused by air entrap during the mold filling were predicted and reduced remarkably by modification of gating system. Also, optimal squeeze-time lag to apply partial squeeze pin in thick area was calculated and the castings was free from shrinkage defects with the result of solidification analysis. Consequently, casting design for automobile transmission gear housing was optimized and approved by Computer Tomography.

Characteristic Analysis of Induction Phenomena in the Nearby Mesh Structure Conductive Part of Large Capacity Wireless Power Transmission System (대용량 무선전력전송 환경 인근 메쉬구조 도전부 유도현상 특성 분석)

  • Chae, Dong-Ju;Yi, Geon-Ho;Lim, Hyun-Sung;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.207-214
    • /
    • 2019
  • A large-capacity wireless power system is a technology that transmits electric power of kW or more in a noncontact type. Electric cars, electric buses, and electric railways. In order to increase the power transmission efficiency, a resonance method using a frequency of kHz is applied and the efficiency is 80 ~ 90%. In this case, the loss is 10 ~ 20% other than efficiency, and corresponds to several hundreds of W to several kW in kW class wireless power transmission. 35 kW wireless feed system environment, and induced current in the nearby conductive part was measured. As a result of analysis, it was confirmed that induction phenomenon is higher as the loop configuration of the conductive part per area is dense. The increase of the induced current in the mesh loop is characterized by the density of the nearby conductive part having a permeability per unit area. The concentration of the magnetic field by the permeability is increased and the induction phenomenon causing the induction current is increased. It was confirmed that induction phenomenon increases by about 2.7 times when 9 times dense structure is formed.

파워트레인 제어 시뮬레이션을 위한 MATLAB/SIMULINK 상에서의 객체지향 프로그래밍

  • 양경진;최재원;홍금식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.208.1-212
    • /
    • 1997
  • In this paper, a computer simulation tool for evaluting integrated engine/transmission control system using MATLAB/SIMULINK is investigated. Since a modular programming technique based upon the object-oriented programming is used in the paper, the simulation tool developed reduces the burden of model complexity by dividing engine/transmission systems into hierarchical subsystem. Furthermore, it also provides user -friendly, reusable, and upgradable characteristics of the system. The simulation tool could be useful to the automotive engineers who frequently change models and develop new systems in the automotive powertrain and control area.

A Study on the Development of PC-card for Information Transmission of Medical Image in the Environment of ISDN(Intergrated Service Digital Network) (종합정보통신망 환경속에서 의료 영상정보 전달을 위한 PC-card 개발에 관한 연구)

  • 이동화;임춘성
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.243-248
    • /
    • 1991
  • This paper described the implementation of high speed transmission fort medical image between hospitals using ISDN. The implemented system, called PC-card, can transmit datas as 144Kbps and can install in the personal computer. So, this enables to get more reliable medical image with less cost, and to service the better quality for an unurbanized area. In this system, installing in the PC system were enhanced to input from medical image system and output to the memory or display

  • PDF

Present State and Development Prospect on the Protective Relaying Under High Resistance Earth Faults in Transmission Systems (송전계통 고저항 지락사고 보호기술 현황 및 개발전망)

  • Lee, Jong-Beom;Kim, Il-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.640-642
    • /
    • 1995
  • This paper describes the present state and development prospect on the protective relaying under high resistance earth faults in transmission systems. Especially it is difficult to detect the fault accompanied with high resistance contary to low resistance. In the complicated power system if the detection is failed, power failure will be occured in large area. New technology with respect to such a problem must be developed. This paper introduces research and development trend in home and abroad.

  • PDF

Noise Evaluation and Measures of Cooling Tower at Apartment (아파트 냉각탑의 소음 평가 및 대책)

  • Lee, Kyu-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1020-1023
    • /
    • 2004
  • Recently, Cooling tower are used the necessary element in a residential area and living space on the viewpoint of indoor temperature control. The purpose of this study is to assistance the comfortable environment and economical measures of noise transmission mechanism on tile cooling tower. The results show that noise evaluation interact the main factor of distance reduction and diffraction reduction. Noise criterion apply to the NC level and equivalent transmission loss about already the design of noise reduction.

  • PDF