• Title/Summary/Keyword: Transient test

Search Result 947, Processing Time 0.033 seconds

Z-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 Z영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Kim, K.Y.;Lee, J.T.;Han, H.H.;An, B.C.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.145-146
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using Z-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger (수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발)

  • Kim, Won-Uk;Park, Hong-Hee;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.

Development and Verification of Thermal Analysis Model for Thermal Vacuum Test of Satellite Components (인공위성 탑재품 수준 열진공 시험에 대한 열해석 모델의 개발과 환경시험 결과를 이용한 검증)

  • Kim, Sang-Ho;Seo, Hyun-Suk;You, Jae-Ho;Han, Eun-Soo;Kim, Tai-Kyung;Kim, Hyeong-Dong;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.8
    • /
    • pp.842-847
    • /
    • 2010
  • Thermal analysis for the simulation of satellite component level thermal vacuum test processes was carried out by considering thermal vacuum test environment condition, thermal vacuum chamber configuration, and satellite's inner thermal environment. The transient analysis results can be obtained for the temperatures of component and thermal vacuum chamber assemblies. The thermal analysis model was verified with the component thermal environmental test results by using enhanced thermal vacuum chamber.

Optimized Synthetic Making Test Facilities for Estimating the Making Performance of Circuit Breaker (차단기의 투입성능 평가를 위한 최적 합성투입시험설비)

  • Suh Yoon-Taek;Kim Maeng-Hvun;Song Won-Pyo;Koh Hee-Seog;Park Seung-Jae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.284-292
    • /
    • 2005
  • Because all of the short-circuit testing laboratories have the limitation of test facilities, the synthetic making test methods have been used to estimate the short-circuit making performance of the ultra high-voltage circuit breaker as the alternative to direct test methods. So, KERI(Korea Eelctrotechnology Research institute) has completed the construction of the synthetic making test facilities using the low capacity step-up transformer method which fulfill the requirements specified in newly revised IEC 62271-100 Edition 1.1(2003) and have the testing capability up to 550kV, 63kA full-pole circuit breaker. The test facilities using the low capacity step-up transformer method presented in this paper are made up of the unit equipments such as HCS(High-speed Closing Switch), ITMC(Initial Transient Making Current) circuit and UP TR(low capacity step-up transformer) and have the operating range of 17.6$^{\circ}$ $\~$ 145.1$^{\circ}$ for testing the circuit breaker rated on up to 50kA and 43.1$^{\circ}$ $\~$ 119.6$^{\circ}$ for more than 50kA.

Factors Influencing the Changes of BAEPs in Vertebrobasilar Transient Ischemic Attacks (추골기저동맥 일과성 허혈발작에서 뇌간청각유발전위변화에 영향을 미치는 인자)

  • Park, Young Hyuk;Yoo, Bong Goo;Kim, Kwang Soo;Yoo, Kyung Moo
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.2
    • /
    • pp.101-106
    • /
    • 2000
  • Background and Purpose : Brainstem auditory evoked potentials(BAEPs) are responses of the brainstem by auditory stimulation. Vertebrobasilar transient ischemic attacks is the disease that occurs by insufficient circulation in the region of brainstem. The purpose of this study is to know the factors influencing the changes of BAEPs in vertebrobasilar transient ischemic attacks. Methods : The subject of study was 96 patients diagnosed as vertebrobasilar transient ischemic attacks. Patients were divided into two groups according to the BAEPs findings. Their age, sex, presence of hypertension, diabetes, hyperlipidemia, heart disease, neurologic findings, previous stroke, previous vertebrobasilar transient ischemic attacks, smoking and alcohol drinking, and time period between symptom onset and testing were compared. Results : There were no significant differences in age, sex, and presence of hypertension, diabetes, hyperlipidemia, heart disease, previous stroke history, previous vertebrobasilar transient ischemic attack, smoking, and alcohol drinking between two groups. The presence of abnormal neurologic findings in the first examination and time period between symptom onset and testing were significantly different between normal BAEPs group and abnormal BAEPs one(P<0.05). Conclusions : The factors influencing the changes of BAEPs were presence of abnormal neurologic findings and time period between symptom onset and testing. These findings suggest that BAEPs test should be performed in acute stage of ischemic attack.

  • PDF

Transient Analysis of a Liquid Rocket Engine System Considering Thrust Control (추력 제어를 고려한 액체로켓 엔진시스템 과도해석)

  • Park Soon-Young;Choi Hwan-Seok;Seol Woo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.4
    • /
    • pp.67-75
    • /
    • 2004
  • It is essential to develop a transient analysis model for the turbopump-fed type liquid rocket engine development, especially for deriving the number of test and its parameters. In this study we proposed a mathematical model of turbopump-fed type liquid rocket engine, and inspected transient mode changes of a rocket engine according to variations of thrust control valve opening ratio. To verify the results, we solved the same problem with AnaSyn software from Russia, and concluded that the results of transient code we developed deviated within 2% from AnaSyn results. Also, using the transient engine analysis code we showed the possibility to find out the system level design Parameters of the components. For example, we modeled a pressure stabilizer which is used to control the consistency of mixture ratio in the gas generator as forced damping system, and found the stability range of the natural frequency and the damping ratio with the transient engine system analysis code.

Correlation between Transient Elastography (Fibroscan®) and Ultrasonographic and Computed Tomographic Grading in Pediatric Nonalcoholic Steatohepatitis

  • Lee, Ji Eun;Ko, Kyung Ok;Lim, Jae Woo;Cheon, Eun Jung;Song, Young Hwa;Yoon, Jung Min
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.3
    • /
    • pp.240-250
    • /
    • 2022
  • Purpose: This study aimed to examine the advantages and usefulness of transient elastography (Fibroscan®) in diagnosing non-alcoholic steatohepatitis in children and adolescents compared to those of abdominal computed tomography and liver ultrasonography. Methods: Forty-six children and adolescent participants aged between 6 and 16 years who underwent transient elastography (Fibroscan®) as well as liver ultrasonography or abdominal computed tomography were included. Thirty-nine participants underwent liver ultrasonography and 11 underwent computed tomography. The physical measurements, blood test results, presence of metabolic syndrome, and the degree of liver steatosis and liver fibrosis were analyzed, and their correlations with transient elastography (Fibroscan®), abdominal computed tomography, and liver ultrasonography, as well as the correlations between examinations, were analyzed. Results: Thirty-six participants (78.3%) were boys, and the mean age was 12.29±2.57 years, with a mean body mass index of 27.88±4.28. In the 46 participants, the mean values for aspartate aminotransferase, alanine aminotransferase, and total bilirubin were 89.87±118.69 IU/L, 138.54±141.79 IU/L, and 0.77±0.61 mg/dL, respectively. Although transient elastography (Fibroscan®) and abdominal computed tomography grading had a statistically significant positive correlation with aspartate aminotransferase and alanine aminotransferase values, the correlations between the results of grading performed by transient elastography (Fibroscan®), abdominal computed tomography, and liver ultrasonography were not statistically. Conclusion: We confirmed that each examination was correlated with the results of some blood tests, suggesting the usefulness and possibility of diagnosis and treatment of steatohepatitis mediated by transient elastography (Fibroscan®) in the department of pediatrics.

Prediction of the Transient Performance of the Passenger Diesel Engine with Turbocharger using HIL (HIL을 이용한 터보과급기 승용 디젤 엔진의 과도 성능 예측)

  • Chung, Jin-Eun;Jin, Young-Wook;Jeong, Dong-Young;Chung, Jae-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.127-132
    • /
    • 2009
  • The transient performance of the passenger diesel engine equipped with the variable geometry turbocharger was simulated using HIL(hardware-in-the-loop) system. The system consists of engine model as software, and the turbocharger test bench as hardware. The engine model is mean value model which is programmed by the Simulink of the Mathworks. The turbocharger test bench is composed of a blower, some sensors, and DAQ boards. A real time simulation is possible since the operating system based on the real time is included. The results show the good response for the transient characteristics. Therefore this HIL system can be used for development of the new turbocharger effectively.

Analysis of Transient Characteristics for Distributed Generations with the Secondary Feeders (저압배전선로에 연계된 분산전원의 과도특성 해석에 관한 연구)

  • Yoon, Gi-Gab;Rho, Dae-Seok;Kim, Eui-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3898-3904
    • /
    • 2010
  • In order to analyze the transient characteristics for distributed generation located with the secondary feeders, this paper constructs a Distributed Generations Filed Test Center which can produce transient characteristics such as voltage sag, swell, interruption, harmonic and so on. And also this paper proposes the test results for the interconnection of distributed generations. The results show the effectiveness for the utility technical guidelines for distributed generations with the secondary feeders.

Thermal Structural Analysis of the Engine Turbocharger under the Transient Temperature History Corresponding to the Motoring Fatigue Test (모터링 내구시험을 상사한 비정상 온도이력을 받고 있는 엔진 터보차져의 열적 거동해석)

  • Choi, Bok-Lok;Bang, In-Wan;Chang, Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.126-132
    • /
    • 2011
  • Fatigue cracks of the turbocharger are often observed for high performance engines under thermal shock tests. Maximum exhaust gas temperature of recently developed gasoline engines could reach approximately $950^{\circ}C$. It's very important to estimate transient temperature histories during thermal shock cycles to predict the stress and the fatigue life of the turbocharger. With these temperature profiles, temperature-dependent material properties and boundary conditions, we could identify critical locations by the application of finite element simulation technologies. In this paper, we applied the reliable analysis approach to the actual turbocharger to predict the weak locations due to the repetitions of plastic strains and compared the results with the crack locations under physical engine test.