• Title/Summary/Keyword: Transient faults

Search Result 124, Processing Time 0.031 seconds

Transient analysis of point defect dynamics in czochralski-grown silicon crystals

  • Wang, Jong-Hoe;Oh, Hyun-Jung;Park, Bong-Mo;Lee, Hong-Woo;Yoo, Hak-Do
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.6
    • /
    • pp.259-263
    • /
    • 2001
  • The continuum model of transient point defect dynamics to predict the concentrations of interstitial and vacancy is established by estimating expressions for the thermophysical properties of intrinsic point defects. And the point defect distribution in a Czochralski-grown 200 mm silicon crystal and the location of oxidation-induced stacking fault ring(OiSF-ring) created during the cooling of crystals are calculated by using the numerical analysis. The purpose of this paper is to show that his approach lead to predictions that are consistent with experimental results. Predicted point defect distributions by transient point defect dynamic analysis are in good qualitative agreement with experimental data under widely and abruptly varying crystal pull rates when correlated with the position of the OiSF-ring .

  • PDF

Analysis of Squirrel Cage Induction Motors with Stator Winding Inter-turn Short Circuit (고정자 권선 단락에 따른 농형 유도전동기의 특성해석)

  • Kim, Mi-Jung;Kim, Byong-Kuk;Moon, Ji-Woo;Cho, Yun-Hyun;Hwang, Don-Ha;Kang, Dong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.150-152
    • /
    • 2007
  • The stator faults yield asymmetrical operation of induction machines, such as irregular current, torque pulsation, increased losses and decreased average torque. So it is necessary to detect the stator faults and develope the monitoring system for detecting faults including vibration and noise. This paper describes the method to analysis the induction motors with the stator winding inter-turn short for investigation of the asymmetrical operation during normal and transient states. And a simple method is used for the simulation and analysis of the induction machines with stator asymmetries. Finally, simulation results, finite element analysis and experimental ones are presented. The results can be useful for real-time on-line monitoring of an induction motor.

  • PDF

Simulation of Capacitively Graded Bushing for Very Fast Transients Generated in a GIS during Switching Operations

  • Rao, M.Mohana;Rao, T. Prasad;Ram, S.S. Tulasi;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.36-42
    • /
    • 2008
  • In a gas insulated substation (GIS), Very Fast Transient Over-voltages (VFTOs) are generated due to switching operations and ground faults. These fast transients are associated with high frequency components of the order of a few hundreds of MHz. These transients may cause internal faults i.e., layer-to-layer faults or minor faults in a capacitively graded bushing, which is one of the important pieces of terminal equipment for GIS. In the present study, the PSPICE model has been developed to calculate the voltage distribution across the layers of 420kV graded bushing for high frequency pulses of rise time 1 to 50ns, which simulate the VFTO. For this simulation, an equivalent electrical network of bushing with different equivalent layers has been considered. The effect of different equivalent layers modeling circuits on the non-uniform voltage factor has been analysed. The influence of copper strip inductance on voltage distribution across layers has also been analysed for various rise times of high frequency transients. Finally, the leakage current of the bushing is calculated for evaluating the bushing condition under these transients.

Design of SPS in the Korean Power System Against Faults on 765 KV Lines

  • Park Jong-Young;Park Jong-Keun;Jang Byung-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.132-137
    • /
    • 2005
  • In Korea, the protection systems against the instability of the nation's power system are insufficient in contrast with many other countries. In addition, there have just been studies carried out on detecting power system instability, while only a few studies pertaining to protection plans against instability exist. This paper focuses on systems to protect against the instability phenomena in the Korean power system. In this paper, we survey possible contingencies in the Korean power system and suggest outline and specs of the SPS (System Protection Scheme) against faults on the 765 kV line, based on simulations. It is concluded that event-based SPS for transient stability is appropriate for the Korean power system. In the simulations, the most severe contingency on the Korean power system is the fault on 765 kV transmission lines. If one of these lines is tripped by a fault, synchronism may be lost on the power plants near this line because of heavy power flow carried by them. In addition, undervoltage in the Metropolitan region is a serious problem in this case since this region receives about half its total power flow through these lines. In order to prevent a synchronism loss, some power plants have to be rejected according to the situations in the simulations.

A Configurable Software-based Approach for Detecting CFEs Caused by Transient Faults

  • Liu, Wei;Ci, LinLin;Liu, LiPing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.5
    • /
    • pp.1829-1846
    • /
    • 2021
  • Transient faults occur in computation units of a processor, which can cause control flow errors (CFEs) and compromise system reliability. The software-based methods perform illegal control flow detection by inserting redundant instructions and monitoring signature. However, the existing methods not only have drawbacks in terms of performance overhead, but also lack of configurability. We propose a configurable approach CCFCA for detecting CFEs. The configurability of CCFCA is implemented by analyzing the criticality of each region and tuning the detecting granularity. For critical regions, program blocks are divided according to space-time overhead and reliability constraints, so that protection intensity can be configured flexibly. For other regions, signature detection algorithms are only used in the first basic block and last basic block. This helps to improve the fault-tolerant efficiency of the CCFCA. At the same time, CCFCA also has the function of solving confusion and instruction self-detection. Our experimental results show that CCFCA incurs only 10.61% performance overhead on average for several C benchmark program and the average undetected error rate is only 9.29%. CCFCA has high error coverage and low overhead compared with similar algorithms. This helps to meet different cost requirements and reliability requirements.

New Control Method of Converter to Improve Transient Response in HVDC Link System (직류송전에서 과도응답특성 개선을 위한 컨버터의 제어)

  • Min, Wan-Ki;Yoo, Myeong-Ho;Kim, Yeong-Han;Choi, Jeo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.342-344
    • /
    • 1996
  • This paper describes the usefulness of new control method in HVDC link system which suffers from severe condition of weak ac system. The proposed control scheme is used for the positive feedback control which directly controlls dc current at dc link system. The object of this paper is to improve the transient response of HVDC link system in disturbances such as faults. To achieve this objective, digital time-domain simulations are employed by the Electro Magnetic Transient Program for DC system(EMTDC).

  • PDF

Damping Analysis using IEEEST PSS and PSS2A PSS

  • Lee Sang-Seung;Kang Sang-Hee;Jang Gwang-Soo;Li Shan-Ying;Park Jong-Keun;Moon Seung-Il;Yoon Yong-Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.271-278
    • /
    • 2006
  • This paper scrutinized the damping effects of installing the prototype PSSs by a transient analysis for eight buses of faults in the South Korean power system. The PSSs used have the co-PSS blocks for IEEEST model with a single input and the co+power PSS blocks for PSS2A model with dual inputs. The simulation tool was a TSAT(Transient Security Assessment Tool) developed by Powertech Labs Inc. The voltages of the transmission line for simulations were 765kV and 345kV, and the faults for eight cases were sequenced by considering the open state and the close state of the lines. In the simulations, the three-phase line to ground (L-G) fault generated different points for each region. The simulations were compared to the cases of no PSS, partial IEEEST and PSS2A, absolute IEEEST, and absolute PSS2A to show that the power system oscillation can be effectively damped by PSS modules. Simulations were conducted to confirm the effectiveness for the KEPCO (Korea Electric Power Corporation) power system.

Studies on the Performance Variation of a Variable Speed Vapor Compression System under Fault and Its Detection and Diagnosis (가변속 증기압축 냉동시스템에서 고장시의 성능변화와 고장 감지 및 진단에 관한 연구)

  • Kim Minsung;Kim Min Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • An experimental study has been peformed to develop a scheme for fault detection and diagnosis(FDD) in a vapor compression refrigeration system. This study is to analyze fault effect on the system performance and to find efficient diagnosis rules for easy determination of abnormal system operation. The refrigeration system was operated with a variable speed compressor to modulate cooling capacity. The FDD system was designed to consider transient load conditions. Four major faults were considered, and each fault was detected over wide operating load range by separating the system response to the load change. Rule-based method was used to diagnose and classify the system faults. From the experimental results, COP degradation due to the faults in a variable speed system is severer than that in a constant speed system. The method developed in this study can be used in the fault detection of refrigeration systems with a variable speed compressor.

Fault Recovery and Optimal Checkpointing Strategy for Dual Modular Redundancy Real-time Systems (중복구조 실시간 시스템에서의 고장 극복 및 최적 체크포인팅 기법)

  • Kwak, Seong-Woo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.112-121
    • /
    • 2007
  • In this paper, we propose a new checkpointing strategy for dual modular redundancy real-time systems. For every checkpoints the execution results from two processors, and the result saved in the previous checkpoint are compared to detect faults. We devised an operation algorithm in chectpoints to recover from transient faults as well as permanent faults. We also develop a Markov model for the optimization of the proposed checkpointing strategy. The probability of successful task execution within its deadline is derived from the Markov model. The optimal number of checkpoints is the checkpoints which makes the successful probability maximum.

Power Swing Detection Using rms Current Measurements

  • Taheri, Behrooz;Razavi, Farzad
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1831-1840
    • /
    • 2018
  • During a power swing, distance relays may mistakenly spread fault throughout the power grid, causing a great deal of damage. In some cases, such mistakes can cause global outages. For this reason, it is critical to make a distinction between power swings and faults in distance relays. In this paper, a new method is proposed based on RMS measurement to differentiate between faults and power swings. The proposed method was tested on two standard grids, demonstrating its capability in detecting a power swing and simultaneous fault with power swing. This method required no specific configurations, and was independent of grid type and zoning type of distance relays. This feature in practice allows the relay to be installed on any grid with any kind of coordination. In protective relays, the calculations applied to the microprocessor is of great importance. Distance relays are constantly calculating the current RMS values for protection purposes. This mitigates the computations in the microprocessor to detect power swings. The proposed method was able to differentiate between a fault and a power swing. Furthermore, it managed to detect faults occurring simultaneously with power swings.