• Title/Summary/Keyword: Transient characteristics

Search Result 1,782, Processing Time 0.029 seconds

A Fundamental Study on the Impulse Responses of Ground Rod Attendant upon Soil Discharges (토중방전을 수반하는 접지봉의 임펄스응답에 대한 기초적 연구)

  • Yoo, Yang-Woo;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.62-69
    • /
    • 2014
  • This paper deals with the fundamental characteristics of transient and conventional ground impedances associated with soil discharges when the lightning impulse voltage was applied to a small-sized ground rod. The potential rise responses of the test ground rod to impulse currents were observed. The current-voltage (I-V)curves, transient and conventional ground impedance curves were examined.. To analyze the transient behaviors of ground rod attendant upon soil discharges, the impulse responses of ground rod were compared with those of non-inductive resistor. As a consequence, the potential rise and impedance of ground rod were reduced and the currents dispersed into the earth were increased due to soil discharges near the ground rod. Soil discharges are classified into two regimes; ionization and breakdown phenomena. The potential rise and impulse impedance of ground rod are significantly decreased by breakdown processes in soil.

Development of Fast-Response $CO_2$ Analyzer and Analysis of Engine-out Emission during Transient Condition of SI engine (고속응답 $CO_2$ 분석기의 제작 및 이를 이용한 SI 엔진에서의 실시간 배기가스 분석에 관한 연구)

  • Song, Hyun-Soo;Min, Kyoung-Doug
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3079-3084
    • /
    • 2008
  • A fast response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of SI engine. The analyzer is based on the non-dispersive infrared absorption technique, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it has 18ms with a response to measure the $CO_2$ concentration. The fast response $CO_2$ analyzer was applied to single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for considering the engine-out $CO_2$ characteristic. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated and the transient behaviors on engine-out emission and performance will be improved.

  • PDF

Computer Simulation of an Automotive Air-Conditioning in a Transient Mode

  • Oh, Sang-Han;Won, Sung-Pil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.220-228
    • /
    • 2002
  • The cool-down performance after soaking is very important in an automotive air-conditioning system and is considered as a key design variable. Therefore, transient characteristics of each system component are essential to the preliminary design as well as steady-state performance. The objective of this study is to develop a computer simulation model and ostinato theoretically the transient performance of an automotive air-conditioning system. To do that, the mathematical modelling of each component, such as compressor, condenser, receiver/drier, expansion valve, and evaporator, is presented first of all. The basic balance equations about mass and energy are used in modelling. For detailed calculation, condenser and evaporator are divided into many sub-sections. Each sub-section is an elemental volume for modelling. In models of expansion valve and compressor, dynamic behaviors are not considered in this analysis, but the quasisteady state ones are just considered, such as the relation between mass flow rate and pressure drop in expansion device, polytropic process in compressor, etc. Also it is assumed that there are no heat loss and no pressure drop in discharge, liquid, and suction lines. The developed simulation model is validated by comparing with the laboratory test data of an automotive air-conditioning system. The overall time-tracing properties of each component agreed well with those of test data in this case.

Steady-state and Transient Performance Simulation and Limit Control for Compressor Surge and Turbine Over-temperature of Turboprop Engine (PT6A-62) (터보프롭 엔진(PT6A-62)의 동.정적 성능모사와 압축기 서지 및 터빈 자온 제어연구)

  • 공창덕;기자영;강명철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 2002
  • The steady-state and transient performance simulation program for a turboprop engine(PT6A-62) was developed. Specially this program included some algorithms, such as flat-rated behaviors in performance and limit control algorithms to prevent the compressor surge and the compressor-turbine inlet limit temperature overshoot. In order to minimize analysis errors, on interpolation method in component characteristics using matching errors and specific heat and specific heat ratio, which are functions of temperatures were used. The developed steady state performance analysis program can handle various conditions such as altitude, bleed extraction, inlet temperature and pressure and part throttle, and the transient performance analysis program incorporated a general mode for transient simulation and a control mode for prevention of the compressor surge and the turbine inlet limit temperature overshoot.

Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

A Study on the Performance Transient Phenomenon at the Interface of a Dual Thrust Rocket Motor with Two Kinds Propellant (이종 추진제를 적용한 이중추력 로켓모터 계면에서의 성능 과도 현상에 관한 연구)

  • Kim, Kyungmoo;Lee, Kiyeon;Kim, Jeongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.2
    • /
    • pp.79-87
    • /
    • 2021
  • In this study, we developed a method to predict/analyze the performance of a dual thrust rocket motor that has 2 kinds propellant charged in axial direction. When transitioning from the booster to the suspender stage, a transient phenomenon related to performance occurred at the interface. The causes and characteristics of the transient phenomenon were investigated by comparing them with the results of the combustion test. It was confirmed that the performance transient phenomenon is sensitively generated not only by the shape design between the propellants with different properties of the propellant, but also by errors in manufacturing due to the propellant curing shrinkage.

Transient Grounding Impedance Characteristics of a Concrete Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 콘크리트봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Kim, Jong-Uk;Lee, Kyu-Jin;Choi, Jong-Ki;Choi, Sun-Kyu;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The grounding impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A concrete rod electrode is one of the commonly used grounding electrodes in electric distribution systems. In this paper, the grounding impedance of concrete rods has been measured in frequency raging from 60[Hz] up to 100[kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

Characteristics of the Voltage Waveforms Caused by Human Electrostatic Discharges (인체에 의한 정전기 방전전압 파형의 특성)

  • 이복희;강성만;엄주홍;이태룡
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.113-120
    • /
    • 2002
  • This paper describes characteristics of transient voltage waveforms caused by human electrostatic discharges(ESDs). For purpose of achieving the statistics on the meaningful amplitude and initial slope for transient ESD voltage waveforms, transient voltages due to human ESDs in various conditions were observed. A voltage measuring system with a wide bandwidth from DC to 400[MHz] was employed. ESD voltage waveforms are approximately the same as ESD current waveforms. Also the simulated results, which are calculated by the reposed equivalent circuit, are closely similar to the measured voltage waveforms. ESD voltage waveforms are strongly dependent on the approach speed and material of intruder, a fast approach causes ESD voltage waveform with a steep rise time than for a slow approach. The voltage waveforms from dialect finger ESDs have a relatively long rise time of 10∼30[ns], but their peaks are low. On the other side ESD voltage waveforms causer by screwdriver with insulating handle have a steep slope with a very short, less than 1[ns] rise time, but their initial spikes are extremely high The obtained results in this work would be applied to solve ESD problems for low voltage and small current electronic devices.

Transient Grounding Impedance Characteristics of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems Using EDSA Program (EDSA 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Kim, Min-Sung;Choi, Jong-Kee;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.26-32
    • /
    • 2009
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A copper rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the grounding impedance of copper rods has been measured in frequency raging from 60[Hz] up to 100 [kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.

Transient Creep Analysis in Indentation Tests (압입시험의 천이 크리프 해석)

  • Lee, Jin-Haeng;Lee, Hyung-Yil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.81-90
    • /
    • 2012
  • The indentation test, which is one of the testing methods for evaluating the mechanical properties of materials, can be applied to the evaluation of creep properties. Many studies related to the indentation creep test, however, have just focused on the characteristics of the steady-state creep, so there are wide discrepancies between the uniaxial test and the indentation test. To obtain accurate creep properties, it is therefore important to consider the effects of transient creep. In the present work, the Ogbonna et al.'s work on the spherical indentation test including the transient creep was expanded and applied to the conical indentation creep test. The characteristics of the transient creep were analyzed via finite element simulations and compared with those obtained through spherical indentation. Other effects, such as elastic strain, indenter shape, contact area, and representative strain, which have not been considered properly in prior studies on the creep test, are also discussed.