• Title/Summary/Keyword: Transient behavior

Search Result 739, Processing Time 0.031 seconds

A Study on Initial Transient Behavior in Creep-Fatigue Crack Growth (크리프-피로 균열성장에서의 초기 천이거동에 대한 연구)

  • 백운봉;남승훈;윤기봉
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1722-1729
    • /
    • 1994
  • At early stage of creep-fatigue crack growth tests, initial transient behavior which implies high crack growth rate has been generally observed by some researchers. Since the influence of the initial transient crack growth behavior on the remaining life of components is significant, cause of it should be further studied. In this study, characteristics of the initial transient behavior of 1Cr-1Mo-0.25V steel is studied experimentally by performing creep-fatigue crack growth tests at $538^{\circ}C$ in air under trapezoidal waveshapes. It is verified that the cause of the initial transient behavior is not high ${(C_t)}_{avg}$ values due to the small scale creep condition at the early stage of test, but oxidation-dominated crack growth mechanism during the transient period which is different from the creep-dominated crack growth mechanism in steady crack growth period.

TRANSIENT ANALYSIS OF A QUEUEING SYSTEM WITH MARKOV-MODULATED BERNOULLI ARRIVALS AND OVERLOAD CONTROL

  • Choi, Doo-Il
    • Journal of applied mathematics & informatics
    • /
    • v.15 no.1_2
    • /
    • pp.405-414
    • /
    • 2004
  • This paper considers overload control in telecommunication networks. Markov-modulated Bernoulli process ( MMBP ) has been extensively used to model bursty traffics with time-correlation. Thus, we investigate the transient behavior of the queueing system MMBP/D/l/K queue with two thresholds. The model is analyzed recursively by using the generating function method. We obtain the transient queue length distribution and waiting time distribution at an arbitrary time. The transient behavior of the queueing system helps observing the temporary system behavior.

Step Response of RF Plasma in Carbon Tetrafluoride($CF_4$)

  • So, Soon-Youl;Akinori Oda;Hirotake Sugawara;Yosuke Sakai
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.930-933
    • /
    • 2000
  • To understand the behavior of electron, ions and radicals on radio-frequency non-equilibrium plasma, it is necessary to know the basic information about its fundamental properties and reactions. Especially, the transient response of radio-frequency plasma has an important means of controlling selective etch rates and investigating the stability of a plasma chemical process. In this paper, we present the results of periodic steady-state behavior and transient behavior carbon Tetrafluoride(CF$_4$) discharge at 0.2 Torr in a 2 cm gap parallel-plate. After the number densities of charged particles became steady-state, the applied voltage was increased or decreased in an instant and the transient behavior of charged particles and radicals was investigated from one steady-state to the next steady state.

  • PDF

Robust Stability and Transient Behavior of a Two-Degree-of-Freedom Servosystem (2자 유도 서보계의 강인한 안전성 및 과도특성)

  • 김영복
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.1
    • /
    • pp.59-66
    • /
    • 1996
  • This paper considers robust stability and transient behavior of the Two - Degree - of - Freedom(2DOF) servosystem. A class of uncertainties allowed in the plant model is obtained, to which the servosystem is robustly stable for any gain of the integral compensator. This result implies that if the plant uncertainty is the allowable set defined by the condition, a high - gain compensation can be carried out preserving stability to achieve a high - speed tracking response. The transient behavior attainable by the limit of the high - gain compensation is calculated using the singular perturbation approach.

  • PDF

Improvement of Steam Generator Model for DSNP with Two-Region Tube Bundle Model for CANDU Transient Simulation (2영역 튜브모텔을 고려한 CANDU 시뮬레이션용 DSNP 증기발생기 모델 개선)

  • Cheon, Im-Jae;Seung, Seo-Jae
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.135-140
    • /
    • 1994
  • An improved steam generator model has been developed for the DSNP simulation of normal operational transient behavior of CANDU nuclear power plant. For more realistic prediction of steam generator behavior during transient, tube bundle region is divided into two separate control volumes, subcooled region and saturated region, and the variation of thermal hydraulic properties in the control volume is accounted for more realistic estimates of outlet enthalpy of each control volume. Test results for typical CANDU operational transient case show reasonable transient behavior of steam generator with overall CANDU operation and improved operational characteristics of steam generator with power variation.

  • PDF

A Dynamic Model of U-Tube Steam Generator for CANDU Simulation

  • Lim, Jae-Cheon;Seoungyon Cho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.213-218
    • /
    • 1996
  • A simulation model for the transient behavior of CANDU U-tube steam generator(UTSG) has been developed for application to the simulation of operational transient behavior of CANDU nuclear power plant. For application to CANDU UTSG. tile design characteristics of CANDU UTSG such as Wolsong Units, feedwater inlet near the tube sheet. is approximated. For realistic prediction of thermal hydraulic behavior of and tube bundle region is divided into two separate control volumes, subcooled region and saturated region. and the variation of thermal hydraulic properties within a control volume is considered. Test results for typical CANDU operational transient case show reasonable transient behavior of steam generator and considered to be applicable to the simulation of overall plant.

  • PDF

Development of dynamic behavior of the novel composite T-joints: Numerical and experimental

  • Mokhtari, Madjid;Shahravi, Morteza;Zabihpoor, Mahmood
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.3
    • /
    • pp.385-400
    • /
    • 2018
  • In this paper dynamic behavior (modal analysis and dynamic transient response) of a novel sandwich T-joint is numerically and experimentally investigated. An epoxy adhesive is selected for bonding purpose and making the step wise graded behavior of adhesive region. The effect of the step graded behavior of the adhesive zone on dynamic behavior of a sandwich T-joint is numerically studied. Finite element analysis (FEA) of the T-joints with carbon fiber reinforced polymer (CFRP) face-sheets is performed by ABAQUS 6.12-1 FEM code software. Modal analysis and dynamic half-sine transient response of the sandwich T-joint are presented in this paper. Two verification processes employed to verify the dynamic modeling of the manufactured sandwich panels and T-joint modeling. It has been shown that the step wise graded adhesive zone cases have changed the second natural frequency by about 5%. Also, it has been shown that the different arranges in the step wise graded adhesive zone significantly affect the maximum stresses due to transient dynamic loading by 1112% decrease in maximum peel stress and 691.9% decrease in maximum shear stress on the adhesive region.

Simplified Technique for 3-Dimensional Core T/H Model in CANDU6 Transient Simulation

  • Lim, J.C.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.113-116
    • /
    • 1995
  • Simplified approach has been adopted for the prediction of the thermal behavior of CANDU reactor core during power transients. Based on the assumption that the ratio of mass flow rate for each core channel does not vary during the transient, quasy-steady state analysis technique is applied with predicted core inlet boundary conditions(total mass flow rate and specific enthalpy). For restricted transient case, the presented method shows functionally reasonable estimation of core thermal behavior which could be implemented in the fast running reactor simulation program.

  • PDF

Unsteady Performance Analysis of a Simple Shaft Gas Turbine Cycle (단순 가스터빈 사이클 과도 성능해석)

  • Kim, Soo-Yong;Soudarev, B.
    • 연구논문집
    • /
    • s.30
    • /
    • pp.5-13
    • /
    • 2000
  • The computation scheme of simulating gas turbine transient behavior was developed. The basic principles of this scheme and main input data required are described. Calculation results are presented in terms of whole operating regime of the cycle. The influence of main initial parameters such as starting engine power, moment of inertia of the rotor, fuel supplying schedule etc. on performance characteristics of has turbine during transient operation is studied In addition, bleeding air influence on transient behavior was also considered For validation of the developed code, comparison of present calculation with that of measurement data of the experimental data for the range of operating period studied.

  • PDF

Evaluation of Transient Natural Circulation Behavior during Accident in Low Power /Shutdown Condition of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.458-463
    • /
    • 1997
  • A transient natural circulation behavior during a LOCA at hot-standby operation is evaluated for YGN Units 3/4. The plant initial condition is determined within the EOP limitation as suitable to hot-standby mode and the transient scenario is prepared as relevant to evaluation of transient natural circulation. A 0.4% cold leg break with loss of off-site power is calculated with RELAP5/MOD3.2, whose predictability has been verified for SBLOCA natural circulation test, S-NC-8B. Through one hour transient analysis, it is found that the plant has its own decay heat removal capability by natural circulation following a LOCA, at hot-standby mode. Additional calculation is performed to investigate an effect of HPSI flow on natural circulation.

  • PDF