Functional Expression of P2Y Receptors in WERI-Rb1 Retinoblastoma Cells

  • Kim, Na-Hyun;Park, Kyu-Sang;Sohn, Joon-Hyung;Yeh, Byung-Il;Ko, Chang-Mann;Kong, In-Deok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제15권1호
    • /
    • pp.61-66
    • /
    • 2011
  • P2Y receptors are metabotropic G-protein-coupled receptors, which are involved in many important biologic functions in the central nervous system including retina. Subtypes of P2Y receptors in retinal tissue vary according to the species and the cell types. We examined the molecular and pharmacologic profiles of P2Y purinoceptors in retinoblastoma cell, which has not been identified yet. To achieve this goal, we used $Ca^{2+}$ imaging technique and western blot analysis in WERI-Rb-1 cell, a human retinoblastoma cell line. ATP ($10\;{\mu}M$) elicited strong but transient $[Ca^{2+}]_i$ increase in a concentration dependent manner from more than 80% of the WERI-Rb-1 cells (n=46). Orders of potency of P2Y agonists in evoking $[Ca^{2+}]_i$ transients were 2MeS-ATP>ATP>>UTP=${\alpha}{\beta}$-MeATP, which was compatible with the subclass of $P2Y_1$ receptor. The $[Ca^{2+}]_i$ transients evoked by applications of 2MeS-ATP and/or ATP were also profoundly suppressed in the presence of $P2Y_1$ selective blocker (MRS 2179; $30\;{\mu}M$). $P2Y_1$ receptor expression in WERI-Rb-1 cells was also identified by using western blot. Taken together, $P2Y_1$ receptor is mainly expressed in a retinoblastoma cell, which elicits $Ca^{2+}$ release from internal $Ca^{2+}$ storage sites via the phospholipase C-mediated pathway. $P2Y_1$ receptor activation in retinoblastoma cell could be a useful model to investigate the role of purinergic $[Ca^{2+}]_i$ signaling in neural tissue as well as to find a novel therapeutic target to this lethal cancer.

Semi-Quantitative Analyses of Hippocampal Heat Shock Protein-70 Expression Based on the Duration of Ischemia and the Volume of Cerebral Infarction in Mice

  • Choi, Jong-Il;Kim, Sang-Dae;Kim, Se-Hoon;Lim, Dong-Jun;Ha, Sung-Kon
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권6호
    • /
    • pp.307-312
    • /
    • 2014
  • Objective : We investigated the expression of hippocampal heat shock protein 70 (HSP-70) infarction volume after different durations of experimental ischemic stroke in mice. Methods : Focal cerebral ischemia was induced in mice by occluding the middle cerebral artery with the modified intraluminal filament technique. Twenty-four hours after ischemia induction, both hippocampi were extracted for HSP-70 protein analyses. Slices from each hemisphere were stained with 2,3,5-triphenyltetrazolium chloride (2%), and infarction volumes were calculated. HSP-70 levels were evaluated using western blot and enzyme-linked immunosorbent assay (ELISA). HSP-70 subtype (hsp70.1, hspa1a, hspa1b) mRNA levels in the hippocampus were measured using reverse transcription-polymerase chain reaction (RT-PCR). Results : Cerebral infarctions were found ipsilateral to the occlusion in 10 mice exposed to transient ischemia (5 each in the 30-min and 60-min occlusion groups), whereas no focal infarctions were noted in any of the sham mice. The average infarct volumes of the 2 ischemic groups were $22.28{\pm}7.31mm^3$ [30-min group${\times}$standard deviation (SD)] and $38.06{\pm}9.53mm^3$ (60-min group${\times}$SD). Western blot analyses and ELISA showed that HSP-70 in hippocampal tissues increased in the infarction groups than in the sham group. However, differences in HSP-70 levels between the 2 infarction groups were statistically insignificant. Moreover, RT-PCR results demonstrated no relationship between the mRNA expression of HSP-70 subtypes and occlusion time or infarction volume. Conclusion : Our results indicated no significant difference in HSP-70 expression between the 30- and 60-min occlusion groups despite the statistical difference in infarction volumes. Furthermore, HSP-70 subtype mRNA expression was independent of both occlusion duration and cerebral infarction volume.

가토 근위세뇨관 Basolateral Membrane Vesicle에서 Succinate 이동 특성 (Succinate Transport in Rabbit Renal Basolateral Membrane Vesicles)

  • 김용근;배혜란;임병용
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.307-318
    • /
    • 1988
  • 가토 신장 피질에서 Percoll density gradient방법으로 분리한 basolateral membrane vesicle (BLMV)에서 rapid filtration technique을 이용하여 succinate의 이동 특성을 관찰하였다. $Na^+$은 succinate의 이동을 증가시켜 "overshoot"현상을 보였으며 이러한 효과는 $K^+,{\;}Li^+,{\;}Rb^+,{\;}choline$과 같은 다른 양이온들에 의해 나타나지 않았다. $Na^+$농도변화에 따른 succinate의 이동율은 sigmoid모양을 보였고, $Na^+$에 대한 Hill coefficient는 2.0이었다. soccinate의 이동은 vesicle 내부가 음전압일 때 더욱 증가되었다. BLMV에서 succinate이동은 용액내 pH변화에 따라 영향을 받았으나 brush border membrane vesicle (BBMV)에서는 영향을 받지 않았다. 동력학적 분석결과 succinate의 Km값은 $15.5{\pm}0.94{\;}{\mu}M$이었고 Vmax는 $16.22{\pm}0.25{\;}n{\;}mole/mg{\;}protein/min$이었다. succinate의 이동은 $4{\sim}5$탄소를 가진 dicarboxylate들에 의해 강력하게 억제되었으나 monocarboxylate나 다른 유기음이온들에 의해 영향을 적게 받거나 받지 않았다. succinate의 이동은 DIDS, SITS, furosemide와 같은 음이온 이동 억제제와 harmaline과 같은 $Na^+$ 이동 억제제에 의해 억제되었다. 이들 결과들은 BLMV에서 succinate는 $Na^+$에 의존하여 이동하며 다른 Krebs cycle중간 산물들과 동일한 운반기전을 이용함을 가르킨다. 또한 BLMV에서 succinate의 이동은 그 기질특이성에 있어서 다른 연구자에 의해 보고된 BBMV에서 이동특성과 유사함을 보였다.

  • PDF

냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구 (Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern)

  • 이대혁;김호영
    • 터널과지하공간
    • /
    • 제12권3호
    • /
    • pp.142-151
    • /
    • 2002
  • 대전 식품냉동저장창고 파일럿 공동주위의 거리에 따른 비정상상태의 온도 분포를 산정하기 위해 Claesson(2001)의 해석해 및 Dirichlet과 Neuman 내부 경계조건을 갖는 수치모델들을 검토하였다. 온도 강하 단계동안 일정 표면 온도 경계조건에 기초하고 있는 Claesson의 해석해를 활용한 결과, 실제 암반에서의 온도 계측결과를 오차 평균 0.89$^{\circ}C$ 수준으로서 비교적 정확히 예측할 수 있었는데, $0^{\circ}C$근처의 실험실 암석 열물성을 입력하였고 현지 암반 조건을 표현하기 위한 특별한 물성 보정을 하지 않았다. 내부 공동 암반 벽면을 통한 열유속을 갖는 수치해석의 경우, 대류 열전달계수와 공동 내부 온도가 냉각시간에 따라 변화하기 때문에 경계조건을 가하기 어려운 단점을 극복하기 위해 새로운 경계조건 설정 기법을 제안하였다. 그 결과 오차 평균 1.58$^{\circ}C$의 수준으로서 온도 계측치와 부합하였다. 또한 공동 벽면에서 고정 온도 조건을 갖는 수치해와 비교하였다. 마지막으로 Claesson의 해석해 및 다양한 내부 경계조건을 갖는 수치모델을 활용하여, 공동 주변의 온도 분포를 정확히 예측할 수 있는 일련의 해석 단계 프로그램을 제안하였다.

심폐바이패스없이 시행하는 관상동맥우회술 (Off-Pump Coronary Artery Bypass Grafting)

  • 김기봉;임홍국;허재학;안혁;함병문
    • Journal of Chest Surgery
    • /
    • 제33권1호
    • /
    • pp.38-44
    • /
    • 2000
  • Background: We analyzed the result of the "Off-Pump" Coronary Artery Bypass grafting (OPCAB) performed to minimize inflammatory responses to cardiopulmonary bypass and myocardial ischemia during the aortic cross-clamp period. Material and Method : The preoperative diagnosis operative procedure mortality complication and postoperative course of the 50 patients who underwent OPCAB between January 1998 and September 1998 were analyzed. There were 34 males and 16 females with mean age of 60$\pm$9 years. Preoperative clinical diagnoses were unstable angina in 31(62%) stable angina in 16(32%) and clinical diagnoses were unstable angina in 31(62%) stable angina in 16(32%) and postinfarction angina in 3(6%) patients. Preoperative angiographic diagnoses were three-vessel disease in 25(50%) two-vessel disease in 5(10%) one-vessel disease in 7(14%) and left main disease in 13(26%) patients. There were elective operation in 37 cases and urgent operation in 13 cases. Result: The mean number of grafts was 3.2$\pm$1.2 per patient. Grafts used were unilateral internal thoracic artery in 43 greater saphenous vein in 37 radial artery in 7 bilateral internal thoracic arteries in 4 and right gastroepiploic artery in 2 cases Forty sequential anastomoses were performed in 18 cases. Vessels accessed were left anterior descending artery in 48 diagonal branch in 41 obtuse marginal branch in 30 right coronary artery in 24 posterior descending artery in 9 ramus intermedius in 5 and posterolateral branch in 5 anastomoses. Predischarge coronary angiography performed in 44 patients demonstrated the patency rate of 89.5%(128/143) Operative mortality was 2%(1/150) Postoperative complications were arrhythmia in 5 graft occlusion that needed reoperation in 4. perioperative myocardial infarction in 2 femoral artery thromboembolism developed after the application of IABP in 1 postoperative transient delirium in 1 peripheral compression neuropathy in 1 case. Sixteen patients(32%) were extubated at the operating room and the other patients were extubated at the mean 13$\pm$20 hours after the operation. Mean duration of stay in intensive care unit was 49$\pm$46 hours. Thirteen patients(26%) required blood transfusions perioperatively and the amount of perioperative blood transfusion was mean 0.70$\pm$1.36 pack/patient. Conclusion: OPCAB is suggested to be the ideal technique with less postoperative complication less hospitalization time and less cost.less cost.

  • PDF

습식 TCE 분해반응에서 CoO2/TiO2 촉매의 반응활성 및 표면화학적 구조 (On-stream Activity and Surface Chemical Structure of CoO2/TiO2 Catalysts for Continuous Wet TCE Oxidation)

  • 김문현;추광호
    • 한국환경과학회지
    • /
    • 제14권2호
    • /
    • pp.221-230
    • /
    • 2005
  • Catalytic wet oxidation of trichloroethylene (TCE) in water has been conducted using $TiO_2-supported$ cobalt oxides at $36^{\circ}C$ with a weight hourly space velocity of $7,500\;h^{-1}.\;5\%\;CoO_x/TiO_2$, prepared by using an incipient wetness technique, might be the most promising catalyst for the wet oxidation although it exhibited a transient behavior in time on-stream activity. Not only could the bare support be inactive for the wet decomposition reaction, but no TCE removal also occurred by the process of adsorption on $TiO_2$ surface. The catalytic activity was independent of all particle sizes used, thereby representing no mass transfer limitation in intraparticle diffusion. XPS spectra of both fresh and used Co surfaces gave different surface spectral features for each $CoO_x,\;Co\;2P_{3/2}$ binding energy for Co species in the fresh catalyst appeared at 781.3 eV, which is very similar to the chemical states of $CoTiO_x$ such as $CO_2TiO_4\;and\;CoTiO_3$. The used catalyst exhibited a 780.3-eV main peak with a satellite structure at 795.8 eV. Based on XPS spectra of reference Co compound, the TCE-exposed Co surfaces could be assigned to be in the form of mainly $Co_3O_4$. XRD patterns for $5\%\;CoO_x/TiO_2$ catalyst indicated that the phase structure of Co species in the catalyst even before reaction is quite comparable to the diffraction lines of external $Co_3O_4$ standard. A model structure of $CoO_x$ present predominantly on titania surfaces would be $Co_3O_4$, encapsulated in thin-film $CoTiO_x$ species consisting of $Co_2TiO_4$ and $CoTiO_3$, which may be active for the decomposition of TCE in a flow of water.

X-RAY ASTRONOMY EXPERIMENT ON THE INDIAN SATELLITE IRS-P3

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;SHAH M. R.;MCKERJEE K.;VARIA M. N.;YADAV J. S.;DEDHIA D. K.;MALKAR J. P.;SHAH P.;DAMLE S. V.;MARAR T. M. K.;SEETHA S.
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.429-432
    • /
    • 1996
  • An x-ray astronomy experiment consisting of three collimated proportional counters and an X-ray Sky Monitor (XSM) was flown aboard the Indian Satellite IRS-P3 launched on March 21, 1996 from SHAR range in India. The Satellite is in a circular orbit of 830 km altitude with an orbital inclination of $98^{\circ}$ and has three axis stabilized pointing capability. Each pointed-mode Proportional Counter (PPC) is a multilayer, multianode unit filled with P-10 gas ($90\%$ Ar + $10\%\;CH_4$) at 800 torr and having an aluminized mylar window of 25 micron thickness. The three PPCs are identical and have a field of view of $2^{\circ}{\times}2^{\circ}$ defined by silver coated aluminium honeycomb collimators. The total effective area of the three PPCs is about 1200 $cm^2$. The PPCs are sensitive in 2-20 keV band. The XSM consists of a pin-hole of 1 $cm^2$ area placed 16 cm above the anode plane of a 32 cm$\times$32 cm position sensitive proportional counter sensitive in 3-8 keV interval. The position of the x-ray events is determined by charge division technique using nichrome wires as anodes. The principal objective of this experiment is to carry out timing studies of x-ray pulsars, x-ray binaries and other rapidly varying x-ray sources. The XSM will be used to detect transient x-ray sources and monitor intensity of bright x-ray binaries. Observations of black-hole binary Cyg X-1 and few other binary sources were carried out in early May and July-August 1996 period. Details of the x-ray detector characteristics are presented and preliminary results from the observations are discussed.

  • PDF

노외 실험을 통한 가압경수형 핵연료 피복재의 항복거동연구 (Out-of-Pile Test for Yielding Behavior of PWR Fuel Cladding Material)

  • Yi, Jae-Kyung;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • 제19권1호
    • /
    • pp.22-33
    • /
    • 1987
  • 원자력 발전소에 있어서 정상가동 상태나 이상동작시에 핵연료 피복관의 건전성 확보와 연관하여 피복재의 항복거동은 중요한 문제이다. 급격한 출력상승 상황에서 이산화 우라늄 소결체와 피복관 사이의 노내 조사거동의 차이는 소결체와 피복관 사이에 Contact Pressure를 야기 시킨다. 만일 이 Contact Pressure가 Zircaloy 피복관의 Yield Pressure에 도달하면 피복관에는 영구변형이 일어난다. 이 변형은 원자로의 출력이 정상상태로 회복되더라도 존재하므로 소결체와 피복관 사이의 Gap을 증대시킨다. 이러한 상황을 묘사하기 위해 본 논문에서는 구리 Mandrel과 Zircaloy사이의 열팽창 차이를 이용하는 Mandrel 팽창 실험을 실행했다. 실험 결과 측정된 Zircaloy 피복관의 외경 팽창치와 본 논문에서 유도된 수학적 관계식들을 이용하여 온도에 따른 Zircaloy 피복관의 내부항복압력과 항복응력, 피복재의 항복에 따른 핵연료 소결체와 피복관 사이의 Gap 증대를 구하고, 항복 거동에 따른 온도의 영향을 보기 위해 항복과정의 활성화 에너지를 구했다. 본 실험과 분석에서 얻어진 이들 결과들은 다른 실험 결과들과 상당히 일치하였으며, 이것으로 볼 때 본 논문에서 유도된 관계식들과 Mandrel 팽창 실험이 Zircaloy 피복관의 항복거동과 Gap Expansion 측정에 신뢰성이 있음을 알 수 있었다.

  • PDF

골아세포내 $Ca^{2+}$ 활성도의 조절기전 (Mechanism of $Ca^{2+}$ Regulation in Osteoblast-like Cells)

  • 박미정
    • Journal of Korean Biological Nursing Science
    • /
    • 제1권1호
    • /
    • pp.25-41
    • /
    • 1999
  • Physiological activity of osteoblast including bone formation is known to be closely related to the increase of intracellular $Ca^{2+}$ activity($[Ca^{2+}]_i$) in osteoblast. $Ca^{2+}$ is an important intracellular messenger in diverse cellular functions, and regulation of its level is mediated by the transmembrane $Ca^{2+}$ movement via $Ca^{2+}$ channels, $Na^+-Ca^{2+}$ exchange, and by intracellular $Ca^{2+}$ movement through the intracellular stores. The purpose of this study is to investigate how the intracellular $Ca^{2+}$ is regulated in osteoblast-like cells(OLCs) by measuring $Ca^{2+}$ activity with cell imaging technique. OLCs were isolated from femur and tibia of neonatal rats, and cultured for 7 days. Cultured OLCs were loaded with a $Ca^{2+}$-sensitive fluorescent dye, Fura-2, and fluorescence images were monitored with a cooled CCD camera. The images were processed and analyzed with an image analyzing software. The results were as follows. (1) $[Ca^{2+}]_i$ of OLC decreased as the $Ca^{2+}$ concentration in the superfusing Tyrode solution was lowered. When $Na^+$ concentration in the superfusing solution was decreased, $[Ca^{2+}]_i$ increased.. These suggest that $Ca^{2+}$ flux occurs via the $Na^+-Ca^{2+}$ exchange mechanism. (2) When $Na^+$ in the superfusing solution was removed. a transient $Ca^{2+}$, increase($Ca^{2+}$ spike) was occasionally observed. However, $Ca^{2+}$ spike was not observed after adding 1 ${\mu}M$ thapsigargin. This implies that the generation of $Ca^{2+}$ spike is mediated by the release of $Ca^{2+}$ from endoplasmic reticulum(ER). (3) As the $Ca^{2+}$ concentration in the superfusing solution was raised, the frequency of 0mM $Na^+$-induced $Ca^{2+}$ spike increased, suggesting that $Ca^{2+}$-induced $Ca^{2+}$ release(CICR) mechanism exists. (4) After $[Ca^{2+}]_i$ was decreased with the superfusion of $Ca^{2+}$-free solution containing thapsigargin, the recovery of $[Ca^{2+}]_i$ with reperfusion of 2.5mM $Ca^{2+}$ solution transiently exceeded the control level, suggesting that the depletion of $Ca^{2+}$ in ER induces $Ca^{2+}$ influx from extracellular medium via store-operated $Ca^{2+}$ influx(SOCI) mechanism. (5) $[Ca^{2+}]_i$ was not affected by the superfusion of 25mM $K^+$ Tyrode solution. These results suggest that intracellular $Ca^{2+}$ activity in osteoblast is regulated by transmembrane $Ca^{2+}$ flux via $Na^+-Ca^{2+}$ exchange, $Ca^{2+}$ release from the internal store (ER) via $Ca^{2+}$-induced $Ca^{2+}$ release, and store-operated $Ca^{2+}$ influx across the cell membrane.

  • PDF

Direct Pars Repair Surgery Using Two Different Surgical Methods : Pedicle Screw with Universal Hook System and Direct Pars Screw Fixation in Symptomatic Lumbar Spondylosis Patients

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Rathi, Nitesh Kumar;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권1호
    • /
    • pp.14-19
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the clinical and radiological outcome in symptomatic lumbar spondylolysis patients who underwent a direct pars repair surgery using two different surgical methods; pedicle screw with universal hook system (PSUH) and direct pars screw fixation (DPSF), and compared the results between two different treated groups. Methods : Forty-seven consecutive patients (PSUH; 23, DPSF; 15) with symptomatic lumbar spondylolysis who underwent a direct pars repair surgery were included. The average follow-up period was 37 months in the PSUH group, and 28 months in the DPSF group. The clinical outcome was measured using visual analogue pain scale (VAS) and Oswestry disability index (ODI). The length of operation time, the amount of blood loss, the duration of hospital stay, surgical complications, and fusion status were also assessed. Results : When compared to the DPSF group, the average preoperative VAS and ODI score of the PSUH group were less decreased at the last follow-up; (the PSUH group; back VAS : 4.9 vs. 3.0, leg VAS : 6.8 vs. 2.2, ODI : 50.6% vs. 24.6%, the DPSF group; back VAS : 5.7 vs. 1.1, leg VAS : 6.1 vs. 1.2, ODI : 57.4% vs. 18.2%). The average operation time was 174.9 minutes in the PSUH group, and 141.7 minutes in the DPSF group. The average blood loss during operation was 468.8 cc in the PSUH group, and 298.8 cc in the DPSF group. The average hospital stay after operation was 8.9 days in the PSUH group, and 7 days in the DPSF group. In the PSUH group, there was one case of a screw misplacement requiring revision surgery. In the DPSF group, one patient suffered from transient leg pain. The successful bone fusion rate was 78.3% in the PSUH group, and 93.3% in the DPSF group. Conclusion : The present study suggests that the technique using direct pars screw would be more effective than the method using pedicle screw with lamina hook system, in terms of decreased operation time, amount of blood loss, hospital stay, and increased fusion success rate, as well as better clinical outcome.