• 제목/요약/키워드: Transient Stability Analysis

검색결과 295건 처리시간 0.027초

과도 안정도 해석 프로그램을 위한 상정사고 스크리닝 모듈 개발 (Development of Contingency Screening Module for Transient Stability Analysis Program)

  • 황정희;김천회;장길수;이병준;권세혁;조윤성;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.335-337
    • /
    • 2005
  • The purpose of this work is to explain techniques achieved while developing a transient stability program which is suitable to Korean power system, and to add a module for contingency screening. It concentrates on the development of Contingency Screening Module. In this thesis, a fast contingency screening algorithm SIME(Single Machin Equivalent), which is one of the Hybrid methods for the transient stability assessment is used to develop the contingency screening module. The proposed module is applied to a KEPCO system, and simulation results obtained from the program are compared to those of commercial programs.

  • PDF

고유치감도를 이용한 과도안정도의 상정사고 해석법의 개발 (Contingency Analysis of Transient Stability Using Eigen-Sensitivity)

  • 심관식;남해곤;김용구;송성근;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1042-1045
    • /
    • 1999
  • This paper presents a new method for contingency selection of the transient stability. Contingency ranking in transient stability is done by estimating the change in the imaginary part of electro-mechanical oscillation mode, which represents modal synchronizing coefficient. And the change in the imaginary part is obtained by applying eigen-sensitivity theory of augmented matrix to linear system model. The Proposed algorithm was tested for New England System and compared the results with PSS/E dynamic simulation.

  • PDF

온라인 동적 안전도평가 시스템의 개발 (Development of On-line Dynamic Security Assessment System)

  • 남해곤;송성근;심관식;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.73-76
    • /
    • 2001
  • This paper presents a new systematic contingency selection, screening and ranking method for on-line transient security assessment. Transient stability of a particular generator is influenced most by fault near it. Fault at the transmission lines adjacent to the generators are selected as contingency. Two screening methods are developed using the sensitivity of modal synchronizing torque coefficient and computing an approximate critical clearing time(CCT) without time simulation. The first method, which considers only synchronizing power, may mislead in some cases since it does not consider the acceleration power. The approximate CCT method, which consider both the acceleration and deceleration power, worked well. Finally the Single Machine Equivalent(SIME) method is implemented using IPLAN of PSS/E for detailed stability analysis.

  • PDF

과도 안정도 해석을 위한 다기 계통 2축 모델을 이용한 확장 비반복 알고리즘 (Extended Noniterative Algorithm Using Multi-machine Two-Axis Model for Transient Stability Analysis)

  • 진원석;권용준;문영현;최병곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.125-127
    • /
    • 2003
  • The Conventional time-domain simulation of transient stability requires iterative calculation procedures to consider the saliency of generator. Recently, a non-iterative algorithm has successfully developed to take into account the generator saliency exactly with the use of $E_q'$-model. This study proposes an extended non-iterative algorithm by adopting the two-axis generator model. Given internal voltages and rotor angles of the generators, network voltages and generator currents can be directly calculated by solving a linear algebraic equation, which enables us to reduce the computation time remarkably.

  • PDF

계통안정화를 위한 SMES의 모델링과 적정위치 선정 (A Modeling and Optimal Site of SMES for Power System Stabilization)

  • 김정훈;임재윤;이종필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.494-501
    • /
    • 1999
  • In this research, ANN modeling method of SMES unit is developed for stability analysis, and the optimal site is selected to maximize stabilization effect of SMES unit. The ANN is trained by learning data which is obtained through the application of complex test function into the traditional mathematical mode. In order to verify the validity of proposed modeling method, fault data of sample power system is applied to both the traditional and the ANN models. When the response of traditional and proposed models are compared, the average error for the active and reactive power are 2.51[%], and 0.24[%], respectively. From the comparison, the relevance of proposed method is validated. For the transient stability analysis, an application method of the proposed model is presented, and the transient stability performance index, which describes system stabilization effect of SMES at disturbance, is also suggested, and optimal site selection method of SMES is presented. In the viewpoint of the voltage stability, system stabilization criterion of local bus is presented from P­V curve, and then optimal site which can maximize the voltage stabilization of the whole power system, is decided from the proposed voltage stability performance index.

  • PDF

WEDM 프로세스의 방전 안정성 향상을 위한 실시간 미세제어에 관한 연구 (A Study on the Real-time Micro Control of WEDM Process for the Improvement of Discharging Stability)

  • 권신;남성호;양민양
    • 한국정밀공학회지
    • /
    • 제22권4호
    • /
    • pp.27-36
    • /
    • 2005
  • Some studies have shown that unstable factors are inherent in WEDM process, causing the instability of the discharging pulse to reach about 40∼60% in normal machining. Transient stability is an important subject in WEDM process since there is a close relationship between stability and machining performance, such as the characteristics of a machined surface, machining speed and problem of instability like wire rupture phenomenon. Among the many machining parameters affecting WEDM machining state, three specific parameters (Vr, Ip, off time ) are major controllable variables that can be applied in transient stability control. And, this research investigates the implementation and analysis of real-time micro control of the discharging stability of WEDM (Wire Electric Discharge Machining) process.

신경회로망 부하모델을 이용한 과도안정도 해석기법 (A Method of Transient Stability Analysis Using ANN)

  • 이종필;임재윤;김성수;지평식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.329-331
    • /
    • 2006
  • Load models are important for improving the accuracy of stability analysis. Load characteristics are changed for voltage and frequency condition. In this research, ANN with LMBP learning rule is used to construct the load model. Characteristics of some residential loads are tested under various voltage and frequency conditions. Acquired data are used to construct load models by ANN. Constructed ANN load model are applied to transient stability analysis.

  • PDF

The nonlinear fuzzy intelligent theory for high-bypass-ratio two-spool unmixed-flow jet engines

  • C.C. Hung;T. Nguyen
    • Advances in aircraft and spacecraft science
    • /
    • 제10권4호
    • /
    • pp.369-391
    • /
    • 2023
  • In our research we have offered a solid solution for aeronautical analysis. which can guarantee the asymptotic stability of coupled nonlinear facilities. According to the theoretical solutions and methods presented, the engine of this aircraft is a small high-bypass turbofan engine. using the non-linear aero-motor control approach and this paper focuses on the power management function of the aero-motor control system. These include static controls and transient controls. A mathematical model of the high-bypass-ratio two-spool unmixed-flow aeroengine was developed through a set of nonlinear dynamic equations verified by experimental data. A single actuator using the displacement method is designed to maintain a certain level of thrust under steady-state conditions. and maintains repeatable performance during transient operation from the requested thrust phase to the next. A single controller can compensate for the effects of noise and harmonic noise at many performance points. And the dynamic performance of a single controller is satisfactory during the transient. for fairness Numerical and computer experiments are described in the perfection of the methods we offer in research.

과도 안정도를 고려한 주파수 계전 알고리즘 개발 (The development of frequency relaying algorithm considering a transient stability)

  • 이병현;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.282-283
    • /
    • 2006
  • A frequency relaying algorithm which is used system separation and load shedding to improve transient stability is proposed. The algorithm can trip the generator and shed load in the abnormal frequency condition. The computer simulations of load flow analysis is used to determine the amount of load to be shed in an under frequency condition. Furthermore dynamic brake energization in the simulation is performed for the control of overfrequency.

  • PDF

후면 덧쌓기에 따른 농업용 저수지 제체의 안정성 평가 (Safety evaluation of agricultural reservoir embankment according to backside extension)

  • 이달원;노재진
    • 농업과학연구
    • /
    • 제39권1호
    • /
    • pp.97-110
    • /
    • 2012
  • This study was carried out for safety evaluation, the practical application and improvement of design method of the agricultural reservoir embankment according to backside extension. Seepage analysis, slope stability analysis and finite element analysis were performed for steady state and transient conditions. Also, the pore water pressure, seepage quantity, safety factor and stress-strain behavior according to high water level and rapid drawdown were compared and analyzed. The pore water pressure at contact region between backside extension and old embankment was kept high after rapid drawdown. Therefore, backside extension is recommended that design method is required to be improved and reinforced more than the others raising embankment. The hydraulic gradients before and after backside extension showed high value at the base of the core, but they showed stable state at the upstream slope and downstream slope. The seepage quantity per 1 day and the leakage per 100 m for the steady state and transient conditions appeared to be safe against the piping. The safety factor of slope stability showed high at the steady state, and transient conditions did not show differences depending on the rapid drawdown. The safety factor was appeared high at the upstream slope before backside extension and downstream slope after extension. The excess pore water pressure for steady state and transient conditions showed negative(-) at the upstream slope, it was small at the downstream slope. The mean effective stress (p') showed high at the base of the core and to be wild distribution after the extension. The displacement after extension showed 0.02-0.06 m in the upstream slope, the maximum shear strain after extension was smaller than that before extension.