• 제목/요약/키워드: Transient Simulation Method

검색결과 635건 처리시간 0.024초

Analysis of the effect of flow-induced crystallization on the stability of low-speed spinning using the linear stability method

  • Shin Dong Myeong;Lee Joo Sung;Jung Hyun Wook;Hyun Jae Chun
    • Korea-Australia Rheology Journal
    • /
    • 제17권2호
    • /
    • pp.63-69
    • /
    • 2005
  • The stability of low-speed spinning process exhibiting spinline flow-induced crystallization (FIC) with no neck-like spinline deformation has been investigated using the method of linear stability analysis. Effects of various process conditions such as fluid viscoelasticity and the spinline cooling on the spinning stability have been found closely related to the development of the spinline crystallinity. It also has been found that the FIC makes the system less stable or more unstable than no FIC cases when the spinline crystallinity reaches its maximum possible value, whereas the FIC generally stabilizes the system if the crystallinity doesn't reach its maximum value on the spinline. It is believed that the destabilizing effect of the FIC on low-speed spinning when the crystallinity is fully developed on the spinline is due to the reduction of the real spinning length available for deformation on the spinline. On the other hand, the increased spinline tension caused by the FIC when the maximum crystallinity is not reached on the spinline and thus no reduction in the spinning length occurs, makes the sensitivity of spinline variables to external disturbances smaller and hence stabilizes the system. These linear stability results are consistent with the findings by nonlinear transient simulation, as first reported by Lee et al. (2005b).

과도 다차원 2상 유동 해석을 위한 비정렬 격자계에서의 Semi-Implicit 수치 해법 개발 (The Semi-Implicit Numerical Scheme for Transient Two-Phase Flows on Unstructured Grids)

  • 조형규;박익규;윤한영;김종태;정재준
    • 에너지공학
    • /
    • 제17권4호
    • /
    • pp.218-226
    • /
    • 2008
  • 가압 경수로의 주요 기기에서 발생할 수 있는 과도 2상 유동(Two-phase flow) 현상에 대한 해석을 수행하기 위해 원자로 기기 열수력 해석 코드를 개발 중에 있다. 개발중인 기기 열수력 해석 코드는 지배 방정식으로 Two-phase, three-field model을 사용하고 있으며, 복잡한 기하학적 형상의 원자로 기기를 모사하기 위해 비정렬 격자계(Unstructured grid)를 활용하고 있다. 수치해석 기법으로는, 원자로 계통 해석코드 REIAP5가 사용 중이며 대부분의 원자로 내 2상 유동 조건에서 안정적이며 정확하다고 알려진 Semi-implicit 방법을 적용하였다. 그러나 기존의 Semi-implicit 방법은 1차원, 엇갈림격자(Staggered grid)에 대해 개발되었기 때문에 이를 다차원, 비정렬, 비엇갈림 격자(Non-staggered grid)에 적용하기 위해 기존의 Semi-implicit 방법을 수정하였다. 본 논문에서는 수정된 Semi-implicit 방법을 소개하고 이를 이용해 수행한 예비 계산결과를 수록하였다.

신경회로를 이용한 GMA 용접 공정에서의 용융지의 크기 제어 (Control of Weld Pool Size in GMA Welding Process Using Neural Networks)

  • 임태균;조형석;부광석
    • Journal of Welding and Joining
    • /
    • 제12권1호
    • /
    • pp.59-72
    • /
    • 1994
  • This paper presents an on-line quality monitoring and control method to obtain a uniform weld quality in gas metal arc welding (GMAW) processes. The geometrical parameters of the weld pool such as the top bead width and the penetration depth plus half back width are utilized to assess the integrity of the weld quality. Since a good quality weld is characterized by a relatively high depth-to-width ratio in its dimensions, the second geometrical parameter is regulated to a desired one. The monitoring variables are the surface temperatures measured at various points on the top surface of the weldment which are strongly related to the formation of the weld pool The relationship between the measured temperatures and the weld pool size is implemented on the multilayer perceptrons which are powerful for realization of complex mapping characteristics through training by samples. For on-line quality monitoring and control, it is prerequisite to estimate the weld pool sizes in the region of transient states. For this purpose, the time history of the surface temperatures is used as the input to the neural estimator. The control purpose is to obtain a uniform weld quality. In this research, the weld pool size is directly regulated to a desired one. The proposed controller is composed of a neural pool size estimator, a neural feedforward controller and a conventional feedback controller. The pool size estimator predicts the weld pool size under growing. The feedforward controller compensates for the nonlinear characteristics of the welding process. A series of simulation studies shows that the proposed control method improves the overall system response in the presence of changes in torch travel speed during GMA welding and guarantees the uniform weld quality.

  • PDF

아날로그-디지털 변환기의 정적 파라미터 테스트를 위한 내장 자체 테스트 방법 (A Built-in Self-Test of Static Parameters for Analog-to-Digital Converters)

  • 김인철;장재원;강성호
    • 대한전자공학회논문지SD
    • /
    • 제49권5호
    • /
    • pp.30-36
    • /
    • 2012
  • 본 논문은 천이 검출기를 이용하여 아날로그-디지털 변환기(ADC)의 정적 파라미터를 테스트 하는 내장 자체 테스트 방법을 제안한다. 제안하는 방법은 ADC의 정적 테스트에서 가장 널리 사용되는 히스토그램 방법을 대체할 수 있다. 입력되는 테스트 신호는 상향 램프 신호를 사용하며 오프셋, 게인, INL(Integral Non-Linearity), DNL(Differential Non-Linearity)과 같은 정적 파라미터를 테스트 할 수 있다. 제안하는 방법은 실제 테스트 환경에서 랜덤 노이즈에 의해 발생할 수 있는 천이 구간 문제를 해결할 수 있으며, 테스트 스펙으로 주어지는 오차 허용 범위의 다양한 경우에 대해서 효율적으로 테스트를 수행할 수 있다. 실험 결과는 제안하는 방법이 정적 테스트를 올바르게 수행하는 것과, 기존 방법에 비해 하드웨어 오버헤드가 줄어드는 것을 보여준다.

Modified Direct Torque Control using Algorithm Control of Stator Flux Estimation and Space Vector Modulation Based on Fuzzy Logic Control for Achieving High Performance from Induction Motors

  • Rashag, Hassan Farhan;Koh, S.P.;Abdalla, Ahmed N.;Tan, Nadia M.L.;Chong, K.H.
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.369-380
    • /
    • 2013
  • Direct torque control based on space vector modulation (SVM-DTC) protects the DTC transient merits. Furthermore, it creates better quality steady-state performance in a wide speed range. The modified method of DTC using SVM improves the electrical magnitudes of asynchronous machines, such as minimizing the stator current distortions, the stator flux with electromagnetic torque without ripple, the fast response of the rotor speed, and the constant switching frequency. In this paper, the proposed method is based on two new control strategies for direct torque control with space vector modulation. First, fuzzy logic control is used instead of the PI torque and a PI flux controller to minimizing the torque error and to achieve a constant switching frequency. The voltages in the direct and quadratic reference frame ($V_d$, $V_q$) are achieved by fuzzy logic control. In this scheme, the switching capability of the inverter is fully utilized, which improves the system performance. Second, the close loop of stator flux estimation based on the voltage model and a low pass filter is used to counteract the drawbacks in the open loop of the stator flux such as the problems saturation and dc drift. The response of this new control strategy is compared with DTC-SVM. The experimental and simulation results demonstrate that the proposed control topology outperforms the conventional DTC-SVM in terms of system robustness and eliminating the bad outcome of dc-offset.

비특이화 간접경계적분방정식방법을 이용한 2차원 수치수조 개발 및 적용 (Development and Application of Two-Dimensional Numerical Tank using Desingularized Indirect Boundary Integral Equation Method)

  • 오승훈;조석규;정동호;성홍근
    • 한국해양공학회지
    • /
    • 제32권6호
    • /
    • pp.447-457
    • /
    • 2018
  • In this study, a two-dimensional fully nonlinear transient wave numerical tank was developed using a desingularized indirect boundary integral equation method. The desingularized indirect boundary integral equation method is simpler and faster than the conventional boundary element method because special treatment is not required to compute the boundary integral. Numerical simulations were carried out in the time domain using the fourth order Runge-Kutta method. A mixed Eulerian-Lagrangian approach was adapted to reconstruct the free surface at each time step. A numerical damping zone was used to minimize the reflective wave in the downstream region. The interpolating method of a Gaussian radial basis function-type artificial neural network was used to calculate the gradient of the free surface elevation without element connectivity. The desingularized indirect boundary integral equation using an isolated point source and radial basis function has no need for information about the element connectivity and is a meshless method that is numerically more flexible. In order to validate the accuracy of the numerical wave tank based on the desingularized indirect boundary integral equation method and meshless technique, several numerical simulations were carried out. First, a comparison with numerical results according to the type of desingularized source was carried out and confirmed that continuous line sources can be replaced by simply isolated sources. In addition, a propagation simulation of a $2^{nd}$-order Stokes wave was carried out and compared with an analytical solution. Finally, simulations of propagating waves in shallow water and propagating waves over a submerged bar were also carried and compared with published data.

저궤도 지구관측위성 주탑재체 냉각유닛 설계와 열해석 (Design and Thermal Analysis of Focal Plane Assembly Cooling Unit of Earth Observation Camera)

  • 서정기;조희근;이덕규;이승훈;최해진;강석봉
    • 한국항공우주학회지
    • /
    • 제37권6호
    • /
    • pp.580-585
    • /
    • 2009
  • 본 논문은 항우연에서 개발 중인 위성 탑재카메라 FPA-CU(Focal Plane Assembly Cooling Unit) 의 개념설계 및 열설계에 대한 개략적인 내용을 기술하고 있다. FPA-CU은 국내 기술로 설계/제작되는 최초의 우주용 냉각유닛이다. FPA-CU에는 일반적인 히트파이프와 방열판을 이용한 냉각유닛과는 다르게 TBM(Thermal Buffer Mass)이 부착되어 있으므로 열적거동이 기존의 냉각유닛과 다르며, 설계에 있어 천이열전달 해석이 반드시 필요하다. 본 논문에서는 TBM의 용량산출 및 형상적 영향을 포함한 전체 냉각유닛 설계방법을 제시하고 전체 냉각유닛에 대한 열해석 결과를 기술하고 있다. 열해석 결과 냉각유닛의 요구조건을 잘 만족시킴을 알 수 있었으며, 최상단부 히트파이프가 비정상 작동하는 경우 FPA의 온도가 $3{\sim}4^{\circ}C$ 정도 상승함을 알 수 있었다. 본 연구를 통해 위성용 열제어 유닛 설계에 대한 국내 기술적 자립 가능성을 확인할 수 있었다.

분자동역학을 이용한 박막의 열경계저항 예측 및 실험적 검증 (Molecular Dynamics Simulation on the Thermal Boundary Resistance of a Thin-film and Experimental Validation)

  • 석명은;김윤영
    • 한국전산구조공학회논문집
    • /
    • 제32권2호
    • /
    • pp.103-108
    • /
    • 2019
  • 본 논문에서는 비평형 분자동역학 시뮬레이션 기법을 사용하여 알루미늄 박막과 실리콘 웨이퍼 간 열경계저항을 예측하였다. 실리콘의 끝 단 고온부에 열을 공급하고, 같은 양의 열을 알루미늄 끝 단 저온부에서 제거하여 경계면을 통한 열전달이 일어나도록 하였으며, 실리콘 내부와 알루미늄 내부의 선형 온도 변화를 계산함으로써 경계면에서의 온도 차이에 따른 열저항 값을 구하였다. 300K 온도에서 $5.13{\pm}0.17m^2{\cdot}K/GW$의 결과를 얻었으며, 이는 열유속 조건의 변화와 무관함을 확인하였다. 아울러, 펨토초 레이저 기반의 시간영역 열반사율 기법을 사용하여 열경계저항 값을 실험적으로 구하였으며, 시뮬레이션 결과와 비교 검증하였다. 전자빔 증착기를 사용하여 90nm 두께의 알루미늄 박막을 실리콘(100) 웨이퍼 표면에 증착하였으며, 유한차분법을 이용한 수치해석을 통해 열전도 방정식의 해를 구해 실험결과와 곡선맞춤 함으로써 열경계저항을 정량적으로 평가하고 나노스케일에서의 열전달 현상에 관한 특징을 살펴보았다.

물-기체 2상 유동 해석을 위한 Semi-Implicit 방법의 대류항에 대한 이차정확도 확장 (IMPLEMENTATION OF A SECOND-ORDER INTERPOLATION SCHEME FOR THE CONVECTIVE TERMS OF A SEMI-IMPLICIT TWO-PHASE FLOW ANALYSIS SOLVER)

  • 조형규;이희동;박익규;정재준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.290-297
    • /
    • 2009
  • 가압 경수로의 주요 기기에서 발생할 수 있는 과도 2상 유동(Two-phase flow) 현상에 대한 해석을 수행하기 위해 원자로 기기 열수력 해석 코드를 개발 중에 있다. 개발 중인 기기 열수력 해석 코드는 지배 방정식으로 Two-phase, three-field model을 사용하고 있으며, 복잡한 기하학적 형상의 원자로 기기를 모사하기 위해 비정렬 격자계(Unstructured grid)를 활용하고 있다. 수치해석 기법으로는, 원자로 계통 해석코드 RELAP5가 사용 중이며 대부분의 원자로 내 2상 유동 조건에서 안정적이며 정확하다고 알려진 Semi-implicit 방법을 적용하였다. 그러나 기존의 Semi-implicit 방법은 1차원, 엇갈림격자(Staggered grid)에 대해 개발되었기 때문에, 이를 다차원, 비정렬, 비엇갈림 격자(Non-staggered grid)에 적용하기 위해 기존의 Semi-implicit 방법을 수정하였다. 본 논문에서는 Semi-implicit 방법의 대류항을 이차정확도를 갖도록 확장하였으며, 이차정확도에 의한 수치확산의 감소를 평가하기 위해 수행된 수치시험의 결과를 기술하였다. 이차정확도 및 일차정확도로 계산된 값을 해석해 또는 격자 수렴성 시험을 통해 평가해 본 결과, 이차정확도 계산시 수치 확산의 감소 확인하였다.

  • PDF

수력발전설비의 안전도 평가를 위한 수충격 해석 모형 개발 (Development of Water Hammer Simulation Model for Safety Assessment of Hydroelectric Power Plant)

  • 남명준;이재영;정우영
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.760-767
    • /
    • 2020
  • 발전용 수력플랜트 분야는 기후변화 및 에너지 확보를 고려해 향후 지속적인 성장이 전망된다. 수력발전설비는 항상 수충격에 의한 위험에 노출되어 있고, 이에 대한 안정성 확보는 매우 중요하다. 수충격 현상은 밸브의 개도 조정이나 펌프와 터빈의 기동 및 정지 시 관로설비 전반에 걸쳐 발생하며, 예기치 못한 긴급 상황 시에는 더욱 현저하게 나타난다. 이와 같은 수충격에 대한 발전설비의 안정성 검토를 위해 본 연구에서는 수충격 발생 메커니즘을 반영된 특성선법을 적용한 수치해석기법(MOC-FDM: Method of Characteristic-Finite Dimensional Method, 이하 MOC-FDM)을 이용하여 전산수치 모형을 개발하였다. 개발모형은 발전설비의 주요시설인 저수지, 관로, 밸브, 펌프 등 경계조건을 반영하였고 가상시나리오 case를 적용하여 개발모형을 이용한 수치모의를 수행하였다. 개발모형 해석결과의 검증을 위해 발전설비의 주요 지점에서의 해석결과를 각각 제시하였다. 각 case 별 수충격 현상이 양호하게 재현되었으며, 상용모델의 수치해석결과와 비교분석 결과가 거의 유사하게 나타나 개발모형의 신뢰성을 확인하였다. 본 연구에서 제시된 전산수치 모델은 수력발전설비의 운영 중 발생할 수 있는 비정상상태의 유체 거동을 정교하게 예측함으로써 설비의 안정성 검토를 위한 유용한 도구로 활용될 수 있을 것으로 판단된다.