• 제목/요약/키워드: Transient Operations

검색결과 129건 처리시간 0.027초

이중퀜치를 이용한 자속구속형 초전도한류기의 과도전류제한 특성 (Transient Current Limiting Characteristics of Flux-Lock Type SFCL Using Double Quench)

  • 최상재;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권2호
    • /
    • pp.96-100
    • /
    • 2017
  • In this paper, the flux-lock type superconducting fault current limiter (SFCL) using double quench was suggested and its transient current limiting characteristics were analyzed. The suggested flux-lock type SFCL using double quench consists of two magnetically coupled windings and two $high-T_{c}$ superconducting (HTSC) elements connected in series with each winding. To analyze the transient current limiting characteristics of the flux-lock type SFCL using double quench, the short-circuit tests according to the fault angles, which affect the transient component of the fault current right after the fault occurs, were executed. From the comparative analysis for the short-circuit tests at both $0^{\circ}$ and $90^{\circ}$ fault angles, the useful transient current limiting operations of the suggested flux-lock type SFCL through the double or the single quench occurrence were confirmed.

PARAMETRIC STUDIES ON THERMAL HYDRAULIC CHARACTERISTICS FOR TRANSIENT OPERATIONS OF AN INTEGRAL TYPE REACTOR

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Song, Chul-Hwa;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.185-194
    • /
    • 2006
  • Transient operations for an integral type reactor, SMART-P, have been experimentally investigated using a thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), in order to verify the system design and performance of the SMART-P, a pilot plant of SMART. The VISTA facility was subjected to various accident conditions such as feedwater increase and decrease, loss of coolant flow, and control rod withdrawal accidents in order to elucidate the thermal-hydraulic responses following such accidents and finally to verify the system design of the SMARTP. Full functional control logics have been implemented in the VISTA facility in order to control the required control action for an accident simulation. As one of the sensitivity tests to verify the PRHRS performance, the effects of the initial water level in the compensation tank are experimentally investigated. When the initial water level is 16%, the water is quickly drained and nitrogen gas is then introduced into the PRHR system, resulting in deterioration of the PRHRS performance. It is thus found that nitrogen ingression should be prevented to ensure stable PRHRS operation.

Cascaded Propagation and Reduction Techniques for Fault Binary Decision Diagram in Single-event Transient Analysis

  • Park, Jong Kang;Kim, Myoungha;Kim, Jong Tae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.65-78
    • /
    • 2017
  • Single Event Transient has a critical impact on highly integrated logic circuits which are currently common in various commercial and consumer electronic devices. Reliability against the soft and intermittent faults will become a key metric to evaluate such complex system on chip designs. Our previous work analyzing soft errors was focused on parallelizing and optimizing error propagation procedures for individual transient faults on logic and sequential cells. In this paper, we present a new propagation technique where a fault binary decision diagram (BDD) continues to merge every new fault generated from the subsequent logic gate traversal. BDD-based transient fault analysis has been known to provide the most accurate results that consider both electrical and logical properties for the given design. However, it suffers from a limitation in storing and handling BDDs that can be increased in size and operations by the exponential order. On the other hand, the proposed method requires only a visit to each logic gate traversal and unnecessary BDDs can be removed or reduced. This results in an approximately 20-200 fold speed increase while the existing parallelized procedure is only 3-4 times faster than the baseline algorithm.

시변성(時變性) 전계(電界) 측정용(測定用) 센서에 관한 연구 (A study on the sensor for measuring the transient electric fields)

  • 이복희;백용현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.318-321
    • /
    • 1991
  • For measuring the transient electromagnetic fields and related quantities created by disconnector operations in GIS, one needs the wide bandwidth sensors with simple transfer functions. This paper describes a new developed electric field sensor to measure the very fast transient electric fields and voltages, and the measuring principle, design and construction of planar electric field sensor are described. A calibration and/or correction technique of the sensor is investigated which enables an accurate determination of the sensor response to the time-changing electric fields. As a consequence, the low voltage calibrations certify that a rise time of 1.7 [ns] is achieved for the planar electric field sensor and a total bandwidth extending from several Hz to 200 MHz for the measuring system which presents the constant division ratio as a function of frequency.

  • PDF

An Adaptive Autoreclosure Scheme with Reference to Transient Stability for Transmission Lines

  • Heo, Jeong-Yong;Oh, Yun-Sik;Seo, Hun-Chul;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.795-803
    • /
    • 2015
  • Autoreclosure provides a means of improving power transmitting ability and system stability. Conventional reclosure adopts the fixed dead time interval strategy, where the reclosure is activated after a time delay to restore the system to normal as quickly as possible without regard to the system conditions. However, these simple techniques cannot provide optimal operating performance. This paper presents an adaptive autoreclosure algorithm including variable dead time, optimal reclosure, phase-by-phase reclosure and emergency extended equal-area criterion (EEEAC) algorithm in order to improve system stability. The reclosure algorithm performs the operations that are attuned to the power system conditions. The proposed adaptive reclosure algorithm is verified and tested using ATP/EMTP MODELS, and the simulation results show that the system oscillations are reduced and the transient stability is enhanced by employing the proposed adaptive reclosure algorithm.

On-line Training of Neural Network for Monitoring Plant Transients

  • Varde, P.V.;Moon, B.S.;Han, J.B.
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 춘계 학술대회 학술발표 논문집
    • /
    • pp.129-133
    • /
    • 2003
  • The work described in this paper deals with the proposed application of an Artificial Neural Network Model for the Advanced Pressurized Water Reactor APR-1400 transient identification. The approach adopted for testing the network take note of the expectation which should be fulfilled by a network for real-time application, like testing with data in on-line mode and use of actual or real-life patterns for training. The recall test performed demonstrates that use of neural network for transient identification is indeed an attractive preposition.

  • PDF

송전선로의 과도 안정도를 고려한 적응 자동재폐로 기법 (An Adaptive Autoreclosure Scheme with Reference to Transient Stability for Transmission Lines)

  • 허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.698-704
    • /
    • 2003
  • Autoreclosure provides a mean of improving power transmitting ability and system stability. The conventional reclosure adopts the fixed dead time interval strategy, that is, the reclosure is activated after a time delay to restore the system to normal as quickly as possible without regard to the system conditions, however, these simple techniques cannot give the optimal operating performance. For this reason, various adaptive reclosure algorithms have been proposed recently, This paper presents an adaptive autoreclosure algorithm including the variable dead time, optimal reclosure, sequential reclosure and emergency extended equal-area criterion (EEAC) algorithm in order to improve the system stability. The reclosure algorithm performs out the operations that are attuned to the power system conditions. The proposed adaptive reclosure algorithm is verified and tested by using EMTP MODELS, and the simulation results show that the system oscillations are reduced and the transient stability is enhanced by employing the proposed adaptive reclosure algorithm.

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of a Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.24-30
    • /
    • 2000
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seen that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stress predictions.

  • PDF

ELT(Emergency Locator Transmitter) 운용을 위한 낙하 충격 및 추락생존성 시험에 대한 수치 해석적 연구 (Numerical Study of Drop/impact test and Shock/impact Survivability Test for ELT(Emergency Locator Transmitter) Operations)

  • 정도희;백종진
    • 한국항공우주학회지
    • /
    • 제36권12호
    • /
    • pp.1229-1235
    • /
    • 2008
  • 비상위치송신기(ELT)는 무수한 조난시의 응급구조에 큰 역할을 해왔다. 비행사, 항해사 그리고 지상 사용자들은 세상 어디에서든지 비상시에 조난신호를 위성에 송신이 가능한 장치를 갖추고 있는 것이다. 이 논문에서는 비상위치송신기의 본체를 낙하충격에 대하여 MSC/Dytran을 이용하여 해석하였다. 그리고 그 결과를 Karas' Example 이론 결과에 비교하였다. 또한, 추락생존성 시험에 대해 MSC/Nastran을 이용해 해석하였다. 비상위치송신기의 충격조건하에 과도응답해석을 하였다.

Senning 및 Mustard 수술후 장기 성적 (Late Results of the Senning and Mustard Operations for TGA in Children)

  • 서경필
    • Journal of Chest Surgery
    • /
    • 제22권1호
    • /
    • pp.32-41
    • /
    • 1989
  • We scrutinized the 64 cases of TGA and Taussig-Bing anomaly who underwent Senning and Mustard operations from Jan. 1981 to May 1988. The ratio of male to female was 45; 19, and the age at operation varied from 2 months to 18 years [mean 18.9*32.9 months]. The in-hospital mortality was in 24 cases [37.5%] and the major causes were myocardial failure and congestive heart failure associated with arrhythmias. The risk factors for hospital mortality were complex TGA, prolonged bypass time and high postoperative CVP. In addition, mortality increased during the first year the procedure was used. Late mortality occurred in 6 cases and the major causes was congestive heart failure, and there was not any significant risk factor noted in late mortality. Early arrhythmia developed in 37.5%, all of which were transient and self limited and 7 cases of early mortality were related to the arrhythmias. Late arrhythmias developed in 8 cases, but 7 cases were transient. One case died with junctional tachycardia. Of significance the one case that died late by arrhythmia had a similar junctional tachycardia in the early postoperative period. The survival rate in all cases disregarding initial in-hospital mortality 1YSR 89.8% and 5YSR 84.3%, but because of short duration of follow up this is not significant. We concluded that early hospital mortality could be decreased by operating at an earlier age and by adjusting the appropriate operation method.

  • PDF