• Title/Summary/Keyword: Transient Magnetic Field

Search Result 101, Processing Time 0.021 seconds

Study on Prediction Method for ELF Transient Magnetic Field from Home Appliances (가전기기에서 발생되는 극저주파 과도자계 예측기법 연구)

  • Ju, Mun-No;Yang, Kwang-Ho;Myung, Sung-Ho;Min, Suk-Won
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.616-621
    • /
    • 2002
  • With biological effects by ELF (Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. Because the transient magnetic field induces higher current than the power frequency field inside living bodies, transient magnetic field exposure has been much focused. In this paper, it is shown that transient magnetic field from electric home appliances can be characterized as magnetic dipole moment. In this method, the dipole moment vector is assumed by allowing an uncertainty of 6dB in the estimated field. A parameter M that represents biological interaction was applied also. The proposed method was applied to 7 types of appliances (hair drier, heater, VDT, etc.) and their equivalent magnetic dipole moment and harmonic components were estimated. As the results, the useful data for quantifying magnetic field distribution around electric appliances were obtained.

Transient Response of Magnetic Field Integral Equation Using Laguerre Polynomials as Temporal Expansion Functions (라겐르 함수를 시간영역 전개함수로 이용한 자장 적분방정식의 과도 응답)

  • 정백호;정용식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.4
    • /
    • pp.185-191
    • /
    • 2003
  • In this Paper, we propose an accurate and stable solution of the transient electromagnetic response from three-dimensional arbitrarily shaped conducting objects by using a time domain magnetic field integral equation. This method does not utilize the conventional marching-on in time (MOT) solution. Instead we solve the time domain integral equation by expressing the transient behavior of the induced current in terms of temporal expansion functions with decaying exponential functions and Laguerre·polynomials. Since these temporal expansion functions converge to zero as time progresses, the transient response of the induced current does not have a late time oscillation and converges to zero unconditionally. To show the validity of the proposed method, we solve a time domain magnetic field integral equation for three closed conducting objects and compare the results of Mie solution and the inverse discrete Fourier transform (IDFT) of the solution obtained in the frequency domain.

Finite Element Analysis of the Transient Characteristics of a Superconducting A.C. Generator (유한요소법에 의한 초전도교류 발전기의 과도 특성 해석)

  • 한성진;배동진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.1
    • /
    • pp.24-30
    • /
    • 1991
  • This paper deals with the analysis of the transient characteristics of a superconducting a.c. generator(SCG) using Finite Element Method. Since the magnetic field induced by the field current and the armature currents are not sinusoidally distributed in a generator, the conventional equivalent circuit method, in general, uses the fundamental component only and is done in frequency domain. But the finite element analysis makes it possible to analyze the transient magnetic field distribution and the electrical characteristics of the double shields of SCG in time domain.

  • PDF

Estimation of Output Voltage and Magnetic Flux Density for a Wireless Charging System with Different Magnetic Core Properties

  • Park, Ji Hea;Kim, Sang Woo
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.105-110
    • /
    • 2013
  • The design model and key parameters of the material design for the control of induced magnetic flux at the near-field and efficient power transfer in a modified wireless power transfer (WPT) system with a large air gap of wireless electric vehicles were investigated through analytical simulations for magnetic vector and time-domain transient analysis. Higher saturation magnetic core with low core loss induced a stronger vertical magnetic field by the W-type primary coil in the WPT system with a gap of 20 cm at 20 kHz, which is shown from the vector potentials of the magnetic induction. The transient analysis shows that the higher magnetic fluxes through the pick-up cores lead to a linear increment of the alternating voltage with a sinusoidal waveform in the non-contact energy transfer system.

Study on the Recoil Operation of the Servomotor with PM Poles (PM형 제어용 Servo전동기의 Recoil동작에 관한 연구)

  • Se Hoon Chang
    • 전기의세계
    • /
    • v.21 no.4
    • /
    • pp.15-21
    • /
    • 1972
  • For the conventional DC machine, the armature MMF is negligible compared with field MMF except when the machine is under heavy load or transient conditions. During the motor starting or reversal, the transient armature current and corresponding MMF effect the flux density of each pole in the machine magnetic circuit. However, the circuit flux density is restored to normal values by the field winding MMF after the transient armature current dies in an electromagnetic DC motor. Permanent magnet servomotor have no field windings about the circuit poles to restore circuit flux density through the demagnetized part of each pole after the transient armature MMF dies, and portions of the magnetic circuit stay permanently demagnetized. Thus the problem of stabilizing a magnet pole piece under the influence of the transient armature current need attentions. This work present the recoil operation of the servomotor with PM poles in conjunctions with the influence of the armature reaction effect. The development of an analytical and quantatative study is presented for predicting the regime of the recoil operation under this condition.

  • PDF

Properties of transient horizontal magnetic fields and their implication to the origin of quiet-Sun magnetism

  • Ishikawa, Ryohko
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.84.1-84.1
    • /
    • 2012
  • Recent spectropolarimetric observations with high spatial resolution and high polarization sensitivity have provided us with new insight to better understand the quiet-Sun magnetism. This talk is concerned with the ubiquitous transient horizontal magnetic fields in the quiet-Sun, as revealed by the Solar Optical Telescope (SOT) on board Hinode satellite. Exploiting the SOT data with careful treatment of photon noise, we reveal the enigmatic properties of these horizontal magnetic fields such as lifetime, size, position in terms of granular structure, occurrence rate, three-dimensional structure, total magnetic flux, field strength distribution, relationship with the meso- and super-granulations and so on. Based on these observational consequences, we conjecture that the local dynamo process, which takes place in a relatively shallow layer with the granular size, produces these transient horizontal magnetic fields and that these horizontal magnetic fields contribute to the considerable amount of quiet-Sun magnetic fields. We also estimate the magnetic energy flux carried by these horizontal magnetic fields based on the statistical data, and find that the total magnetic energy is comparable to the total chromospheric and coronal energy loss, implying their important role for the chromospheric heating and dynamism.

  • PDF

Measurement of Magnetic Field Generated by the Operations of Electric Appliance (전기기구의 운전에 의하여 발생되는 자계의 측정)

  • 이복희;길경석;박형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1001-1009
    • /
    • 1994
  • The present paper deals with a new developed sensor for measuring the time-varying magnetic fields and describes the experimental results of trasient magnetic field that takes place during the operations of electric appliance. The operation principle of the self-integrating magnetic field sensor by using coaxial cable is analyzed and a calibration investigation is carried out. The frequency bandwidth of the magnetic field measurement system is from 40 Hz to about 300 kHz. The magnetic field induced by the starting and/or operation of electric appliance mainly includes the odd harmonics such as the third, the fifth and the seventh harmonics. The magnetic field intensity caused during the operation of ultrasonic washer is inversely proportional to distance, this correspodns to induction component. As a result, it was known that the odd harmonics of magnetic field in the desing of electromagnetic shield employed for protecting electronic circuit and control devices have to be considered.

  • PDF

Analysis of Transient Scattering from 3-Dimensional Arbitrarily Shaped Conducting Structures Using Magnetic Field Integral Equation (자장 적분방정식을 이용한 3 차원 임의 형태 도체 구조의 지연 산란 해석)

  • 정백호;김채영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.379-387
    • /
    • 2002
  • In this paper, we present a procedure to obtain the transient scattering response from three-dimensional arbitrarily shaped and closed conducting bodies using time-domain magnetic field integral equation (TD-MFIE) with triangular patch functions. This approach results in accurate and comparably stable transient responses from conducting scatterers. Detailed mathematical steps are included, and several numerical results are presented and compared with results from a time-domain electric field integral equation (TD-EFIE) and the inverse courier transform solution of the frequency domain results.

Transient Analysis of Electromagnetic Scattering From Dielectric Objects Using Time-Domain Magnetic Field Integral Equation (시간영역 자장 적분방정식을 이용한 유전체의 전자파 산란 과도해석)

  • 서정훈;정백호;한상호;안현수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.412-417
    • /
    • 2003
  • In this Paper, we propose a time-domain magnetic field integral equation (TD-MFIE) formulation for analyzing the transient electromagnetic response from three-dimensional (3-D) dielectric bodies. The solution method in this paper is based on the Galerkin's method that involves separate spatial and temporal testing procedures. Triangular patch basis functions are used for spatial expansion and testing functions for arbitrarily shaped 3-D dielectric structures. The time-domain unknown coefficients of the equivalent electric and magnetic currents are approximated tv a set of orthonormal basis function that is derived from the Laguerre polynomials. These basis functions are also used for the temporal testing. Numerical results computed by the proposed method are presented and compared.

The Role of Magnetic Topology in the Heating of Active Region Coronal Loops

  • Lee, Jin-Yi;Barnes, Graham;Leka, K.D.;Reeves, Katharine K.;Korreck, K.E.;Golub, L.;Deluca, E.E.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.86.2-86.2
    • /
    • 2011
  • We investigate the evolution of coronal loop emission in the context of the coronal magnetic field topology. New modeling techniques allow us to investigate the magnetic field structure and energy release in active regions (ARs). Using these models and high-resolution multi-wavelength coronal observations from the Transition Region and Coronal Explorer and the X-ray Telescope on Hinode, we are able to establish a relationship between the light curves of coronal loops and their associated magnetic topologies for NOAA AR 10963. We examine loops that show both transient and steady emission, and we find that loops that show many transient brightenings are located in domains associated with a high number of separators. This topology provides an environment for continual impulsive heating events through magnetic reconnection at the separators. A loop with relatively constant X-ray and EUV emission, on the other hand, is located in domains that are not associated with separators. This result implies that larger-scale magnetic field reconnections are not involved in heating plasma in these regions, and the heating in these loops must come from another mechanism, such as smallscale reconnections (i.e., nanoflares) or wave heating. Additionally, we find that loops that undergo repeated transient brightenings are associated with separators that have enhanced free energy. In contrast, we find one case of an isolated transient brightening that seems to be associated with separators with a smaller free energy.

  • PDF