• 제목/요약/키워드: Transient Control Level

검색결과 161건 처리시간 0.03초

Static Synchronous Series Compensator(SSSC) 댐핑 제어 및 해석모형 (Damping Control Strategy and Analysis Model of Static Synchronous Series Compensator(SSSC))

  • 김학만;전영환;오태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.509-515
    • /
    • 2000
  • This paper addresses a damping control strategy of Static Synchronous Series Compensator(SSSC) and analysis model for stability study. The effect of injected voltage source generated by SSSC is modelled as equivalent load. This model is thought to be reasonable for the stability study because the dynamics of SSSC is very fast compared with that of power system. Damping controller of SSSC is based on Transient Energy Function method. The proposed control strategy is insensitive to the operating conditions like power flow level because control law depends on the phase angles. The proposed analysis model and control strategy was confirmed by WSCC 9 bus system and two area system. Especially, the robustness of proposed control strategy is demonstrated with respect to multiple operating conditions in two area system.

  • PDF

SMA 작동기를 이용한 유연외팔보의 능동진동제어 (Active Vibration Control of a Flexible Cantilever Beam Using SMA Actuators)

  • 최승복;정재천;황인수
    • 한국정밀공학회지
    • /
    • 제12권9호
    • /
    • pp.167-174
    • /
    • 1995
  • This paper experimentally demonstrates the feasibility of using shape memory alloy(SMA) actuators in controlling structural vibrations of a flexible cantilevered beam. The dynamic characteristics of the SMA actuator are identified and integrated with the beam dynamics. Three types of control schemes; constant amplitude controller(CAC), proportional amplitude controller (PAC) and sliding mode controller(SMC) are designed. The CAC and PAC are determined on the basis of physical phenomenon of the SMA actuator, while teh SMC is formulated in a mathematical manner. The proposed controllers are implemented and evaluated at various operating condirions by investigating the control level of suppression in transient vibration.

  • PDF

Effect of Sodium Hydrosulfite Solution on Agrobacterium-Mediated Chinese Cabbage Transformation and Transient Expression

  • Park Hee-Sung;Shin Dong-Il
    • Journal of Plant Biotechnology
    • /
    • 제7권4호
    • /
    • pp.219-223
    • /
    • 2005
  • We investigated chemical-wounding effect on Agrobacterium-mediated Chinese cabbage transformation via vacuum infiltration. Pre-germinated or germinating Chinese cabbage seeds were infiltrated with Agrobacterium tumefaciens LBA4404 cells carrying either GUS gene (pBI121) or hepatitis B virus surface antigen DNA (pBIHBsAg). Prior to agroinfiltration process, the seeds were soaked in sodium hydrosulfite (SHS) solution or just in sterile water as a control. Comparative transformation efficiency was determined by both of histochemistry and ELISA. We could demonstrate that SHS solution treatment especially to 1-day or 2-days old germinating seeds efficiently improved transformation process, and therefore, transient expression level. This strongly indicated that Agrobacterium infection could be facilitated indeed by SHS-causing wounds on Chinese cabbage seeds.

Harmonic Current Compensation based on Three-phase Three-level Shunt Active Filter using Fuzzy Logic Current Controller

  • Salim, Chennai;Benchouia, M.T.;Golea, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.595-604
    • /
    • 2011
  • A three-phase three-level shunt active filter controlled by fuzzy logic current controller which can compensate current harmonics generated by nonlinear loads is presented. Three-level inverters and fuzzy controllers have been successfully employed in several power electronic applications these past years. To improve the conventional pwm controller performance, a new control scheme based on fuzzy current controller is adopted for three-level (NPC) shunt active filter. The scheme is designed to improve compensation capability of APF by adjusting the current error using a fuzzy rule. The inverter current reference signals required to compensate harmonic currents use the synchronous reference detection method. This technique is easy to implement and achieves good results. To maintain the dc voltage across capacitor constant and reduce inverter losses, a proportional integral voltage controller is used. The simulation of global system control and power circuits is performed using Matlab-Simulink and SimPowerSystem toolbox. The results obtained in transient and steady states under various operating conditions show the effectiveness of the proposed shunt active filter based on fuzzy current controller compared to the conventional scheme.

채널 가감 파장분할다중(WDM)망에서 EDFA 이득의 빠른 과도 응답 제어 (A fast transient control of EDPA gain on channel add/drop WDM networks)

  • 박정문;이상헌;신서용;송성호
    • 한국통신학회논문지
    • /
    • 제30권4A호
    • /
    • pp.233-240
    • /
    • 2005
  • 본 논문에서는 파장분할다중(WDM)망에 적용된 어븀첨가 광섬유증폭기(EBFA)의 이득이 채널의 가감(add/drop)게 따라 변화하는 것을 EDFA의 3-레벨 모델을 기반으로 하는 비례-적분-미분 제어기(PID controller)가 적용된 새로운 외란관측기법을 통해 제어함으로써 이득회복시간을 $3\mu$sec 이하까지 단축시킬 수 있음을 보였다. $3\mu$sec이하의 이득회복 및 안정화 시간은 지금까지 발표된 것들 가운데 가장 빠른 것으로 종전에 2-레벨 EDFA 모델을 기반으로 하는 PI 제어기가 사용된 외란관측기법을 통해 얻었던 $250\mu$sec의 약 $1\%$, 그리고 현재 상용화되어 있는 WDM 망용 EDFA의 가장 빠른 이득회복시간인 $200\mu$sec의 $2\%$도 채 안되는 시간이다. 이러한 결과는 외란관측기의 파라미터와 PI 제어기의 제어 파라미터의 변화에 따른 시스템의 특성 변화를 분석하여 제어기를 최적함으로써 얻어 낼 수 있었으며, 이를 상용화에 적용할 경우, 향후 유동적(dynamic) WDM 망에서 매우 중요한 역할을 할 것으로 전망된다.

Performance Analysis of SSSC with Switching-level Simulation Model and Scaled Hardware Model

  • Han, Byung-Moon;Kim, Hee-Joong;Baek, Seung-Taek
    • Journal of Power Electronics
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 2001
  • This paper describes a switching-level simulation model and scaled hardware model for SSSC, which is useful for analyzing the dynamic interaction between the SSC and the power transmission system. A detailed simulation model with EMTP was developed to verity the SSSC operation with control system, and its increasing capability of power transmission through the line for a typical one-machine infinite-bus system. The simulation results of the developed model are compared with the experimental results froma scaled model fo 2KVA rating for evaluation the whole system operation.

  • PDF

Steady-State/Transient Performance Simulation of the Propulsion System for the Canard Rotor Wing UAV during Flight Mode Transition

  • Kong, Changduk;Kang, Myoungcheol;Ki, Jayoung
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.513-520
    • /
    • 2004
  • A steady-state/transient performance simulation model was newly developed for the propulsion system of the CRW (Canard Rotor Wing) type UAV (Unmanned Aerial Vehicle) during flight mode transition. The CRW type UAV has a new concept RPV (Remotely Piloted Vehicle) which can fly at two flight modes such as the take-off/landing and low speed forward flight mode using the rotary wing driven by engine bypass exhaust gas and the high speed forward flight mode using the stopped wing and main engine thrust. The propulsion system of the CRW type UAV consists of the main engine system and the duct system. The flight vehicle may generally select a proper type and specific engine with acceptable thrust level to meet the flight mission in the propulsion system design phase. In this study, a turbojet engine with one spool was selected by decision of the vehicle system designer, and the duct system is composed of main duct, rotor duct, master valve, rotor tip-jet nozzles, and variable area main nozzle. In order to establish the safe flight mode transition region of the propulsion system, steady-state and transient performance simulation should be needed. Using this simulation model, the optimal fuel flow schedules were obtained to keep the proper surge margin and the turbine inlet temperature limitation through steady-state and transient performance estimation. Furthermore, these analysis results will be used to the control optimization of the propulsion system, later. In the transient performance model, ICV (Inter-Component Volume) model was used. The performance analysis using the developed models was performed at various flight conditions and fuel flow schedules, and these results could set the safe flight mode transition region to satisfy the turbine inlet temperature overshoot limitation as well as the compressor surge margin. Because the engine performance simulation results without the duct system were well agreed with the engine manufacturer's data and the analysis results using a commercial program, it was confirmed that the validity of the proposed performance model was verified. However, the propulsion system performance model including the duct system will be compared with experimental measuring data, later.

  • PDF

Real Time Control of an Induction Motor Using IMC Approach

  • Nghia, Duong Hoai;Nho, Nguyen Van;Bac, Nguyen Xuan;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.456-463
    • /
    • 2009
  • The paper presents a method for controlling induction motors using a nonlinear internal model control (IMC) approach. The process model and the inverse model are developed in the rotor flux coordinate. The main advantage of the proposed method is that it easily specifies the performance (steady state error, transient response, etc.) and the robustness of the controller by means of the IMC filters. Simulation results illustrate the effectiveness of the proposed method. Results on a real time system show that the control system has good performance and robustness against changes in motor parameters (rotor and stator resistances, rotor and stator inductances, rotor inertia).

Modeling and Direct Power Control Method of Vienna Rectifiers Using the Sliding Mode Control Approach

  • Ma, Hui;Xie, Yunxiang;Sun, Biaoguang;Mo, Lingjun
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.190-201
    • /
    • 2015
  • This paper uses the switching function approach to present a simple state model of the Vienna-type rectifier. The approach introduces the relationship between the DC-link neutral point voltage and the AC side phase currents. A novel direct power control (DPC) strategy, which is based on the sliding mode control (SMC) for Vienna I rectifiers, is developed using the proposed power model in the stationary ${\alpha}-{\beta}$ reference frames. The SMC-based DPC methodology directly regulates instantaneous active and reactive powers without transforming to a synchronous rotating coordinate reference frame or a tracking phase angle of grid voltage. Moreover, the required rectifier control voltages are directly calculated by utilizing the non-linear SMC scheme. Theoretically, active and reactive power flows are controlled without ripple or cross coupling. Furthermore, the fixed-switching frequency is obtained by employing the simplified space vector modulation (SVM). SVM solves the complicated designing problem of the AC harmonic filter. The simplified SVM is based on the simplification of the space vector diagram of a three-level converter into that of a two-level converter. The dwelling time calculation and switching sequence selection are easily implemented like those in the conventional two-level rectifier. Replacing the current control loops with power control loops simplifies the system design and enhances the transient performance. The simulation models in MATLAB/Simulink and the digital signal processor-controlled 1.5 kW Vienna-type rectifier are used to verify the fast responses and robustness of the proposed control scheme.

유전 알고리듬을 이용한 개선된 QFT의 루프 형성법 및 원전 증기발생기 수위제어계의 설계 (An improved Loop Shaping Approach of QFT using Genetic Algorithm and a Design of Steam Generator Water Level Control System in Nuclear Power Station)

  • 김주식;김민환;유정웅
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.106-113
    • /
    • 1998
  • 원자력발전소의 증기발생기 수위제어계는 과도상태뿐만 아니라 정상운전 시에도 제어계 설계에 사용된 모델링이나, 이론의 적용이 매우 어려운 계통이다. 따라서 기존의 제어방법으로는 안정성에 대한 의문이 제기되어 많은 연구가 이루어지고 있다. 이러한 문제점에 입각하여 본 연구에서는 유전 알고리즘을 이용한 개선된 루프 형성법을 제안하고 이 방법올 QFT에 적용하여 제어성능을 향상시킬 수 있는 제어계를 설계하였다. 그리고 시뮬레이션 결과로부터 안정성과 효과적인 제어성능을 얻었다.

  • PDF