• Title/Summary/Keyword: Transient

Search Result 8,392, Processing Time 0.043 seconds

Evaluation of Transient Natural Circulation Behavior during Accident in Low Power /Shutdown Condition of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.458-463
    • /
    • 1997
  • A transient natural circulation behavior during a LOCA at hot-standby operation is evaluated for YGN Units 3/4. The plant initial condition is determined within the EOP limitation as suitable to hot-standby mode and the transient scenario is prepared as relevant to evaluation of transient natural circulation. A 0.4% cold leg break with loss of off-site power is calculated with RELAP5/MOD3.2, whose predictability has been verified for SBLOCA natural circulation test, S-NC-8B. Through one hour transient analysis, it is found that the plant has its own decay heat removal capability by natural circulation following a LOCA, at hot-standby mode. Additional calculation is performed to investigate an effect of HPSI flow on natural circulation.

  • PDF

Transient Response Analysis of Rotating Blade Considering Friction Damping Effect of Elastically Restrained Root in Resonant Frequency Range (공진 주파수 영역에서 탄성지지단의 마찰감쇠효과를 고려한 회전 블레이드의 과도응답해석)

  • 윤경재
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.100-112
    • /
    • 2003
  • This paper presents the transient response analysis of a rotating blade in resonant frequency range. It is shown that the modeling is considered in elastic foundation and friction damping effect. The equations of motion are derived and transformed into a dimensionless form to investigate general phenomena. Numerical results show that the magnitude of friction damping to reduce maximum transient response in near the critical angular speed. The method can be applied to a number of examples of the practical rotating blade system to minimize transient response in resonant frequency range.

Application of Lyapunov Theory and Fuzzy Logic to Control Shunt FACTS Devices for Enhancing Transient Stability in Multimachine System

  • Kumkratug, P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.672-680
    • /
    • 2012
  • This paper proposes the control strategy of the shunt Flexible AC Transmission System (FACTS) devices to improve transient stability in multimachine power system. The multimachine power system has high nonlinear response after severe disturbance. The concept of Lyapunov energy function is applied to derive nonlinear control strategy and it was found that the time derivative of line voltage is not only can apply to control the shunt FACTS devices in multimachine system but also is locally measurable signal. The fuzzy logic control is also applied to overcome the uncertainty of various disturbances in multimachine power system. This paper presents the method of investigating the effect of the shunt FACTS devices on transient stability improvement. The proposed control strategy and the method of simulation are tested on the new England power system. It was found that the shunt FACTS devices based on the proposed nonlinear control strategy can improve transient stability of multimachine power system.

A Study on the Electromagnetic Transients in A Power System (전력계통의 전자과도현상에 관한 연구)

  • 김경철;강창원;이일무
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

Transient Phenomena Analysis of HVDC Submarine Cable (HVDC 해저케이블의 과도현상 해석)

  • Jang, Hwa-Youn;Jeong, Seok-San;An, Chun-Yong;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.490-491
    • /
    • 2011
  • This paper describes the EMTP/ATP Draw modeling HVDC submarine cable. HVDC submarine cables consist of conductor, lead sheath and amore. It is different from general cable which is composed with just conductor and aluminium sheath. Therefore, the transient characteristics are totally different between HVDC submarin cable and general cable. However, the study on HVDC cable modeling and Transient are insufficient. In this paper, characteristic and effectiveness of HVDC Submarine Cable through Transient analysis. Therefore it is evaluated that the application of HVDC Submarine cable at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

  • PDF

Transient Impedance of the Ground Grid and Deeply-driven Ground Rod (그리드접지와 심매설 접지전극의 과도임피던스)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Jeong, Dong-Cheol;Gil, Hyoung-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.240-243
    • /
    • 2005
  • This paper presents the transient behaviors of grounding system impedance against lighting impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current with various rise time were investigated. It was found that the transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system in the short time domain.

  • PDF

NUMERICAL STUDY OF TRANSIENT CONJUGATE HEAT TRANSFER IN A MICRO-CHANNEL SUBSTRATE (마이크로채널 기판에서 비정상 복합 열전달의 수치적 연구)

  • Lee, H.J.
    • Journal of computational fluids engineering
    • /
    • v.17 no.4
    • /
    • pp.87-92
    • /
    • 2012
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under pulsed heating was conducted. It was found that the time constant is not affected by the pulse heating magnitude at same operating condition. Furthermore, the time constant increases with low substrate thermal diffusivity, low Reynolds number, and large channel diameter. Since the time constant is a dominant parameter to characterize transient heat transfer, it should be considered for transient convective heat transfer coefficient.

Preventive Control for Transient Security with Generation Rescheduling Based on Rotor Trajectory Index

  • Verma, Kusum;Niazi, K.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.465-473
    • /
    • 2015
  • The increasing need to improve transient security assessment of existing or forecasted operating conditions of networks by power system operators is major concern of the power system security monitoring problem at the Energy Management Systems. This paper proposes a preventive control of transient stability with generation rescheduling based on rotor trajectory index obtained using time domain simulations. This index may help power engineers in making operational decision and to obtain a generation configuration with better transient security dispatch. The effectiveness of the proposed methodology is demonstrated on IEEE 39-bus New England system for a three phase fault at different loading conditions with single and multiple line outage cases.

A study on the Transient Torsional Vibrations of Four Stroke Marine Diesel Engines (선박용 4행정 디젤엔진의 과도 비틀림 진동에 관할 연구)

  • Lee, D.C.;Yu, J.D.;Jeon, H.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.44-50
    • /
    • 2002
  • Theoretical analysis on the transient torsional vibration was started from early 1960's for high power synchronous motor application. As for marine engineering, simulation and measuring techniques of transient torsional vibration have been steadily studied by manufacturer of flexible coupling and designer of four stroke marine diesel engine. In this paper, the simulation method of transient torsional vibration for four stroke marine diesel engine application using Newmark method is introduced.

  • PDF

Underwater Transient Signal Detection Using Higher-order Statistics and Wavelet Analysis (고차통계 기법과 웨이브렛을 이용한 수중 천이신호 탐지)

  • 조환래;오선택;오택환;나정열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.670-679
    • /
    • 2003
  • This paper deals with application of wavelet transform, which is known to be good for time-frequency analysis, in order to detect the underwater transient signals embedded in ambient noise. A new detector of acoustic transient signals is presented. It combines two detection tools: wavelet analysis and higher-order statistics. Using both techniques, the detection of the transient signal is possible in low signal to noise ratio condition. The proposed algorithm uses the wavelet transform of a partition of the signal on frequency domain, and then higher-order statistics tests the Gaussian nature of the segments.