• 제목/요약/키워드: Transformer-less

검색결과 188건 처리시간 0.032초

154kV 방재형 난연 변압기 냉각특성에 관한 연구 (A Study on the Cooling Characteristic of a 154kV Less-Flammable Power Transformer)

  • 박정호;오원근;하영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.61-64
    • /
    • 2001
  • Demand for development of 154kV Less-Flammable Power transformer is now increasing greatly instead of a oil-immersed transformer for preventing disasters and Less-flammability of substations. The most important point in developing Less-flammable transformer is cooling system. This paper describes the study on cooling characteristic of Less-flammable transformer.

  • PDF

3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션 (3kW multi-string photovoltaic inverter design and simulation)

  • 이종인;유병규;유권종;김흥근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Transformer-Less Single-Phase Four-Level Inverter for PV System Applications

  • Yousofi-Darmian, Saeed;Barakati, Seyed Masoud
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1233-1242
    • /
    • 2014
  • A new inverter topology for single-phase photovoltaic (PV) systems is proposed in this study. The proposed inverter offers a four-level voltage in its output terminals. This feature results in easier filtering in comparison with other conventional two-level or three-level inverters. In addition, the proposed four-level inverter (PFLI) has a transformer-less topology, which decreases the size, weight, and cost of the entire system and increases the overall efficiency of the system. Although the inverter is transformer-less, it produces a negligible leakage ground current (LGC), which makes this inverter suitable for PV grid-connected applications. The performance of the proposed inverter is compared with that of a four-level neutral point clamped inverter (FLNPCI). Theoretical analysis and computer simulations verify that the PFLI topology is superior to FLNPCI in terms of efficiency and suitability for use in PV transformer-less systems.

LCD 백라이트용 트랜스포머 없는 냉음극관(CCFL) 구동 회로 (Transformer-less CCFL Driver for LCD Backlight)

  • 최은석;윤현기;문건우;윤명중;강문식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.81-83
    • /
    • 2006
  • The conventional cold cathode fluorescent lamp (CCFL) driver for LCD TV has a transformer for each lamp to step up the high sinusoidal waveform from the low input voltage. The transformer used in the conventional topology causes the driver to have bulky size and high cost. This paper proposes a new transformer-less CCFL driver for LCD backlight that is based on the parallel-loaded resonant inverter topology. This resonant topology enables the circuit to supply enough high voltage for CCFL without a transformer. Also, with current-balancing technique, this transformer-less inverter drives 16 CCFL lamps.

  • PDF

50% 미만 부하조건에서의 3상 몰드변압기 진동 측정과 분석 (The vibration detection and analysis of 3-phase cast resin transformer in less than 50% load conditions)

  • 송길목;방선배;김종민;김영석;최명일
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.992-997
    • /
    • 2012
  • In this paper, we were analyzed the vibration characteristics of the three-phase cast resin transformer using less than 50% of load in the field. Most of the cast resin transformer is less than 50% in the domestic field is used for load conditions. Consisting of a solid insulator cast resin transformer is generating lots of noise and vibration. In addition, because it is affected by Joule 's heat is used in light load conditions. As a results, the transformer vibrations at frequencies below about from 200Hz to 500Hz were detected. Vibration velocity depends on the load variations were found. Load up to approximately 20-30% in most cases the vibration velocity was found at 4,000 ${\mu}m/s$ or less, 8,000 ${\mu}m/s$ or more. Vibration frequency at light load conditions were generated at the 120Hz, 240Hz, 360Hz and 480Hz. At the load condition of from 10% to 20%, vibration velocity is higher than another. Most of the vibration velocity were identified at the 1,000 ${\mu}m/s$ or less. Using the vibration frequency and velocity measurements data, the load on the cast resin transformer analyzed the correlation of the burden. Therefore, this data could be found in the vibration characteristics of the light-load conditions. If the field measurements using the data perform diagnostics on the transformer, it's expected to be very effective.

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터 (Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise)

  • 이성호;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

Half-bridge 직렬공진 컨버터 적용 무접점 전원장치 효율특성 (Efficiency Characteristics of Half-bridge Series Resonant Converter for the Contact-less Power Supply)

  • 이현관;송환국;김은수;김윤호
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.884-891
    • /
    • 2007
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss and the high voltage gain characteristics for load variations in contact-less power supply (CPS). To consider these characteristics, in this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is presented, described and verified through theoretical analysis, computer simulation and experimental test of 2.5kW prototype.

60Hz 절연변압기가 없는 고주파링크방식 계통연계형 태양광발전시스템 고찰 (Study of 60Hz Transformer-less High Frequency Linked Grid-Connected Power Conditioners for Photovoltaic Power System)

  • 유권종;정영석;최주엽
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.563-569
    • /
    • 2002
  • 본 연구는 60Hz 절연변압기가 없는 형태의 고주파링크방식의 계통연계형 PCS(Power Conditioning System)를 개발하였다. 본 시스템은 고주파 DC-DC 컨버터, 고주파 절연변압기, 풀브리지 다이오드 정류기, DC filter, 저주파 인버터, LC 필터로 구성되어 있다. 고주파 DC-DC 컨버터는 20kHz의 bipolar PWM 펄스를 발생시키며, 이 펄스는 고주파 절연변압기를 통해 승압되고, 풀브리지 다이오드를 통해 정류된다. 마지막으로 저주파 인버터를 통해 정현파 전류가 계통에 유입되게 된다. 제안한 고주파링크방식의 시스템은 기존의 60Hz 절연변압기를 사용하는 시스템 보다 많은 스위칭 소자가 사용되지만, 60Hz 절연변압기를 생략함으로서 시스템의 소형경량화 및 저가화를 이룰 수 있었다.

최상부 유온 상승 특성을 이용한 100kVA 이하 유입식 배전용 변압기의 과부하 판정 기준 (Overload Criterion of Mineral-Oil-immersed Distribution Transformers Rated 100kVA and Less Using the Characteristics of Top-Oil Temperature Rising)

  • 윤상윤;김재철;박창호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.559-567
    • /
    • 2002
  • This paper presents the general recommendations for the overload criterions of mineral-oil-immersed distribution transformers rated 100kVA and less. For this purpose, we analyze the characteristics of top-oil temperature rising for mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea, In order to analyze the characteristics of top-oil temperature rising due to the distribution transformer loading, we performed experiments at KERI (Korea Electrical Research Institute) from December 2000 to May 2001. The restraint of ambient temperatures for the experiment results is solved using the results of foreign standards. Finally, we present the overload criterions of distribution transformer for summer and winter season, respectively.

A Study of the Grid Connected Transformer-less PV PC

  • Park Y.S.;Choi J.H.;Park G.W.;Yu G.J.;Jung Y.S.;Choi J.Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.524-527
    • /
    • 2003
  • This paper describes control of the grid connected transformer-less type photovoltaic(PV) power conditioning system. which is simpler and more efficient than conventional transformer type systems. With modeling and analysis of PV system, the validity of the control strategy was verified by simulations and experimental results.

  • PDF