• Title/Summary/Keyword: Transformer oil

Search Result 400, Processing Time 0.02 seconds

Natural Convection Heat Transfer from a Heated Fine Wire in Nanofluids (나노유체에 잠긴 가는 열선 주위의 자연대류 열전달)

  • Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.9
    • /
    • pp.807-813
    • /
    • 2007
  • Recent research on nanofluids under forced convection experiment shows that there is little relationship between convective heat transfer and thermal conductivity increase of nanofluids. This kind of new findings are totally different from the traditional theory of nanofluids, which says that the higher thermal conductivity is a prerequisite for convective heat transfer enhancement. To elucidate this controversial issue in a very comprehensible manner, simple natural convection experiment has been carried out for the water- and oil-based nanofluids. ($water-Al_2O_3$, transformer $oil-Al_2O_3$) Present research shows that there exists strong dependence between natural convection performance and thermal conductivity increase of nanofluids.

The Thermal Aging Characteristics of Cellulose Paper using Analysis for CO, $CO_2$ Gas and Furan Compounds (CO, $CO_2$ 가스와 Furan 함유량의 분석을 통한 셀룰로오스 절연지의 열 열화특성)

  • Kim, Jae-Hoon;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.499-504
    • /
    • 2009
  • The analysis for furan compound has provided a complementary technique to dissolved gas analysis(DGA) for monitoring transformers when total concentration of CO and $CO_2$ dissolved in oil only has been evaluated the aging of insulating paper. But, the analysis of furanic compounds by high performance liquid chromatography(HPLC) has been important more than DGA recently. Because it has been known that furanic components in transformer oil have come only from the decomposition of insulating paper. Therefore we have manufactured accelerating aging cell which was aged during 60 hours at 100, 150, 180 and $200^{\circ}C$, respectively, for investigating the characteristics of cellulose paper by thermal using analysis for CO, $CO_2$ and furan compound.

A Study on Deterioration Evaluation Method by Condition Monitoring and Diagnosis for Aging Oil-immersed Power Transformers (유입식 변압기의 상태진단을 통한 노후도 평가 방법)

  • Chang, Jeong-Ho;Lee, Sung-Hun;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.297-305
    • /
    • 2014
  • Nowadays new water supply projects have been on the decline as the water-power constructions have saturated, which means that the existing power equipment have slowly aged and they require more efforts to maintain the system performance. An effective asset management method of power equipment has become a great necessity from both economical and technical aspects. To be balanced, the asset management should look into all three parts: management, engineering, and information. The purpose of this paper is to study a Risk-Based Maintenance (RBM) matrix method through the deterioration evaluation algorithm for an efficient reliability assessment of oil-immersed power transformers by considering both asset management and technical evaluation. Make use of this result, the equipment will be decided to be replace or repair otherwise on service.

The Effect of Interface Activation Substances in Reduction Phenomena of Streaming Electrification for Transformer Oil (변압기유의 유동대전 감소현상에 미치는 계면활성제의 효과)

  • Kim, Yong-Woon;Lee, Duck-Chool;Watanabe, Shigeo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.48-51
    • /
    • 2000
  • The purpose of this study is to find the way to reduce the electrostatics by interface activation substances added in the insulating oil with concentration[ppm]. As results, The streaming current, surface tension and viscosity of the samples added nonionic and hermaphrodic substances are decreased but the conductivity is increased at higher point than the 1[ppm](c.m.c.), the other side the same phenomena of the samples added cationic and anionic substances are discovered at the 10[ppm].

  • PDF

A Study on Electrical Properties of Pressboard Insulating Paper (프레스 보드 절연지의 전기물성에 관한 연구)

  • Kim, G.Y.;Eom, S.W.;Ahn, M.S.;Kang, D.P.;Yun, M.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.35-38
    • /
    • 1993
  • Pressboard is used for insulation oil-immersed equipment such as transformer. It's low cost, good electrical properties when immersed in oil, ease of storage and installation, and general reliability have made it virtually a universal choice. This study has examined fabricating specimen and specimen characteristics of pressboard.

  • PDF

A Fault Diagnosis Method of Oil-Filled Power Transformers Using IEC Code based Neuro-Fuzzy Model (IEC 코드 기반의 뉴로-퍼지모델을 이용한 유입변압기 고장진단 기법)

  • Seo, Myeong-Seok;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • It has been proven that the dissolved gas analysis (DGA) is the most effective and convenient method to diagnose the transformers. The DGA is a simple, inexpensive, and non intrusive technique. Among the various diagnosis methods, IEC 60599 has been widely used in transformer in service. But this method cannot offer accurate diagnosis for all the faults. This paper proposes a fault diagnosis method of oil-filled power transformers using IEC code based neuro-fuzzy model. The proposed method proceeds two steps. First, IEC 60599 method is applied to diagnosis. If IEC code can't determine the fault type, neuro-fuzzy model is applied to effectively classify the fault type. To demonstrate the validity of the proposed method, experiment is performed and its results are illustrated.

Breakdown Characteristic of Transformer Oil Depending on Tip Radius (침전극 곡률 반경에 따른 절연유의 절연파괴 특성)

  • Lee, J.S.;Jeong, S.H.;Lee, H.K.;Lim, K.J.;Kim, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1478-1480
    • /
    • 1997
  • We investigated the breakdown characteristic of mineral oil according to applied voltage and tip radius. In this experiment, electrode system was point-plane geometry. The tip radius of needle was 5, 10, 20 and $25{\mu}m$, respectively. Applied voltage was AC and DC. We measured breakdown voltage for each tip radius with increasing electrode gap, 2mm to 10mm. Under nonuniform electric field, breakdown strength was higher when needle was negative than when needle was positive. Because it is polarity effects due to space charge. And the more sharp tip radius, whether we applied AC or DC, the higher breakdown strength. As tip radius increase, breakdown strength decreases exponentially.

  • PDF

Ultrasonic-detection characteristics of optical-fiber sensor for insulation diagnosis (절연진단용 광섬유 센서의 초음파 검출특성)

  • Lee, S.H.;Sim, S.H.;Lee, K.S.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.183-186
    • /
    • 2002
  • It is well known that a discharge in oil is the source of various physical and chemical phenomena. One of them is ultra-sonic wave, and its detection is a useful method to the diagnosis of the transformer insulation condition. Conventionally, ultra-sonic waves are detected by Piezo-electric trans-ducer(PZT), and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test of the ultrasonic-detecting ability was performed for both of PZT and fiber-optic sensor. Discharge test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and showed time-delay characteristics. We analyzed the data with frequency domain and wavelet transform.

  • PDF

Disposal of Polychlorinated Biphenyls(PCBs) by a Combined Chemical with Thermal Treatment (화학 및 열적 처리를 이용한 폴리염화바이페닐(PCB)의 제거)

  • Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.286-293
    • /
    • 1999
  • A comnprehensive process which combines chemical with thermal treatment by controlled counterflow oxidation has been developed for disposal of PCBs in transformer oil. PCBs which not completely removed by chemical treatment, after being filtered with appropriate adsorbent during the oil circulations, was thermally treated. Destruction efficiencies of better than 99.99% was obtained, with no measurable formation of PCDDs (polychlorinated dibenzo-p-dioxins) or PCDFs (polychlorinated dibenzofurans). The combination also permits high recovery of oil and inorganic supports from scrap power transformers. The process is environmentally benign, easy to use and less capital intensive than other available technologies.

  • PDF

Research of Tan$\delta$ Measurement on Pole Transformers using DSP (DSP를 이용한 주상변압기 유전정접 측정기법 연구)

  • 김재철;이보호;김언석;최도혁;이수길
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.110-118
    • /
    • 1997
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformers by using digital signal processor. After applying voltage to the condenser which is in¬stalled in a transformer, acquiring source voltage and current of condenser and using cross-correla¬tion techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross -correlation techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with Schering bridge on degraded insulating oil. The result showed that this measuring tech¬nique can be used as diagnostic method on the pole transformers.

  • PDF