• 제목/요약/키워드: Transformer leakage inductance

검색결과 158건 처리시간 0.027초

두 개의 인덕터를 갖는 PV-MIC용 준공진 부스트 컨버터 (Quasi-resonant Two-Inductor boost converter for PV-MIC)

  • 박승원;김재형;김준구;류동균;김태훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.188-189
    • /
    • 2010
  • This paper proposed a new zero-voltage switching(ZVS) Two-Inductor boost converter. The conventional Two-Inductor boost converter has defect. When the switch is turned off, the high voltage spike is occurred in the switch by leakage inductance and switch parasitic capacitor. To solve this problem, the parallel resonant capacitor is added to the conventional Two-Inductor boost converter. Using quasi-resonant between parallel resonant capacitance and leakage inductance, the switches is operated soft switching. A reduction of transformer turn ratio is achieved by the voltage doubler rectifier.

  • PDF

고주파 트랜스포머의 권선배열에 기법 따른 손실해석 (Power Loss Analysis according to Winding Array Method of High Frequency Transformer)

  • 윤신용;김일남
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.15-19
    • /
    • 2005
  • This paper analyzed the power loss characteristics according to winding thickness and winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM tool. The ferrite core model for analysis be used the EE10 type of TDK cop.. Transformer model objected flyback transformer type applied to flyback converter/inverter. Therefore, analysis results of loss were obtained from inner parameters of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

80-MW 클라이스트론 부하용 200-MW 펄스 트랜스포머의 성능시험 (Performance Test of 200-MW Pulse Transformer for 80-MW Klystron Load)

  • 장성덕;오종석;손윤규;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2167-2169
    • /
    • 1999
  • A pulse transformer producing pulses with the peak power of 200-MW (400 kV 500 A at load side with $4.4{\mu}s$ flat-top) is required to drive the 80-MW pulsed klystron in the PLS linac. We have designed and manufactured the high power pulse transformer with 1 : 17 turn ratio. Its primary functions are to match the impedance of klystron tube to the modulators, and to provide step-up of the voltage. To obtain a fast rise time of the pulse voltage. Low leakage inductance and low distributed capacitance design is very important. In this paper, we discuss the equivalent circuit analysis of the pulse transformer, and present the full power performance test results of pulse transformer.

  • PDF

새로운 형상의 평면변압기를 이용한 LLC 공진컨버터 (LLC Resonant Converter Using A Novel Planar Transformer)

  • 이승민;노영재;강철하;장상호;김은수;정봉근;이광호
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.627-637
    • /
    • 2011
  • 본 논문은 새로운 형상을 가지는 평면 변압기를 적용한 200W급 공진컨버터에 대한 내용이다. 제안된 평면변압기는 기존 누설인덕턴스가 작은 평면변압기와 달리 누설인덕턴스가 조정이 가능하여 원하는 공진 특성을 얻을 수 있는 특징을 가지는 저가형 고집적화에 용이한 변압기이다. 본 논문에서는 제안된 평면변압기를 적용하여 200W급 전원장치에 적용하여 실험하였으며, 실험결과와 이론적인 해석에 대해 서술하였다.

변압기용 권선의 전자장 해석 (Electromagnetic Analysis of Transformer windings)

  • 박찬배;김우석;한송엽;최경달;주형길;홍계원
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.225-228
    • /
    • 2002
  • This paper presents electro-magnetic analysis of IMVA High T$_{c}$ Superconductivity transformer designed conceptually. A winding type of this transformer is a double pancake type, and a transformer of solenoidal winding type is selected to be compared with it. Both transformers have the same sizes and the same turns. Results of the analysis are compared with results of solenoidal winding. And, in this paper, leakage inductances are calculated too. There are a lot of methods to calculate inductance including Neumann Formula, Energy conservation and so on. In this paper, Energy conservation method are selected.d.

  • PDF

제안된 평면변압기를 이용한 LLC 공진컨버터 (LLC Resonant Converter using Proposed Planar Transformer)

  • 이승민;김은수;정봉근;이재삼;김유선;허동영
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.121-128
    • /
    • 2012
  • In this paper, a new planar transformer with a novel core configuration that can regulate the leakage inductance is proposed and described in detail. In order to design the slim size power system for flat panel TV, Two planar transformers applied to LLC resonant converter are connected in series at primary and in parallel by the center-tap winding at secondary. In this paper, a 300W low profile LLC resonant converter was built and tested to verify the proposed planar transformer.

권선형상에 따른 유도전력공급장치 특성해석 (The analysis of IPT transformer by winding structures)

  • 한경희;이병송;권삼영;박현준;이형우;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1259-1260
    • /
    • 2007
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the electric railway vehicle system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The inductive power of secondary part is related to amount of linked flux to secondary part by the length of air-gap, which is expected by such a system parameter as mutual inductance. This paper will study for the transfer characteristic of power from input to output and equation including mutual inductance. And also, effect of leakage inductance variation of inductive power collector according to structure of winding was considered.

  • PDF

무접점 베터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Series Resonant Converter for Non-Contact Battery Charger)

  • 김창균;유정식;박종후;조보형;서동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2508-2511
    • /
    • 1999
  • A non-contact battery charger which transfers energy using magnetic field without any electrical contacts is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the non-contact transformer and ZVS operation can reduce switching losses. In this paper. analysis and design procedure of half-bridge series resonant converter with non-contact transformer is presented. Input voltage is 85VAC ${\sim}$ 270VAC, output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method for calculating the secondary current of the transformer to control battery charging current in constant current charging mode which is required for litium-ion battery is proposed and the performance is verified from experiments.

  • PDF

비접촉식 배터리 충전 장치용 Half-Bridge 직렬 공진 컨버터 분석 및 설계 (Analysis and Design of Half-Bridge Resonant Converter for Non-Contact Battery Charger)

  • 김창균;서동현;유정식;박종후;조보형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.265-271
    • /
    • 2000
  • A non-contact battery charger for cellular phone is designed using half-bridge series resonant converter. This converter utilizes series resonance to reduce the undesirable effect of large leakage inductance of the detachable transformer and ZVS operation can reduce switching loss and switching noise. In this paper, analysis and design procedure of half-bridge series resonant converter with detachable transformer is presented. The input voltage is 85VAC∼270VAC, and the output voltage and current is 4.1V and 800mA, respectively. Furthermore, a method of calculating the secondary current of the transformer to control the battery charging current in the constant current charging mode is proposed. The performance of the charger is verified through experiments.

  • PDF

Analysis and Design of a Bidirectional Cycloconverter-Type High Frequency Link Inverter with Natural Commutated Phase Angle Control

  • Salam, Zainal;Lim, Nge Chee;Ayo, Shahrin Md.
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.677-687
    • /
    • 2011
  • In this paper a cycloconverter-type high frequency transformer link inverter with a reduced switch count is analyzed and designed. The proposed topology consists of an H-bridge inverter at the transformer's primary side and a cycloconverter with three bidirectional switches at the secondary. All of the switches of the cycloconverter operate in non-resonant zero voltage and zero current switching modes. To overcome a high voltage surge problem resulting from the transformer leakage inductance, phase angle control based on natural commutation is employed. The effectiveness of the proposed inverter is verified by constructing s 750W prototype. Experimentally, the inverter is able to supply a near sinusoidal output voltage with a total harmonic distortion of less than 1%. For comparison, a PSpice simulation of the inverter is also carried out. It was found that the experimental results are in very close agreement with the simulation.