• Title/Summary/Keyword: Transformer Oil-paper

Search Result 235, Processing Time 0.03 seconds

Study on Dielectric Characteristics of the Environmental-friendly Pole Transformer using Vegetable Oil (식물성절연유를 사용한 친환경 주상변압기의 절연 특성 연구)

  • Kwag, Dong-Soon;Choi, Jae-Hyeong;Min, Chi-Hyun;Park, Tae-Soo;Kim, Sang-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.921-922
    • /
    • 2007
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

Monitoring method of transformer insulationg oil using pulsed-laser and photodiode (펄스레이저 및 광다이오드를 이용한 변압기 절연유의 절연감시법)

  • Cho, J.S.;Yang, D.M.;An, K.S.;Yoon, S.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2130-2132
    • /
    • 1999
  • This paper is research for the practicability of instrument which can apply to the transformer on the spot with the criteria of insulation oil with the method of measuring the volume of $H_2O$ in the insulation oil by playing insulation oil with the significant role for precaution diagnosis on breakdown of transformer among power system into Nd:YAG laser.

  • PDF

Research on Dielectric Characteristics of Environmental-Friendly Vegetable Insulation Oil for the Pole Transformer (주상변압기 적용을 위한 친환경 식물성절연유의 절연특성 연구)

  • Kwag, Dong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.81-85
    • /
    • 2010
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. The vegetable insulation oils are highly biodegradable, have negligible effect on the environment, human health and ecosystem. Therefore, to assure their safe use in electrical power systems, it may require some processing and modification to improve some of their physical, chemical, thermal and electrical properties. This paper provides a comparative results of the electrical breakdown properties of several vegetable insulation oils and mineral oil to use as dielectric fluid in environmental-friendly pole transformer. Also, the electrical breakdown property of the Nomex and kraft insulation papers in vegetable insulation oil is examined.

Diagnosis for Degradation of Transformer Oil by an Optical Fiber Sensor (광섬유 센서를 이용한 변압기 절연유의 열화 진단)

  • Yi, Sue-Muk;Kim, Tae-Young;Suh, Kwang-S.;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1563-1565
    • /
    • 2000
  • This paper presents the preliminary results on the application of optical fiber sensor(OFS) for the diagnosis of degradation in the transformer oil. An OFS system using a Mach-Zehnder interferometry technique was built to detect attenuation of acoustic signal produced by discharging. With increasing the number of discharging in the insulation oil, the attenuation of acoustic signal became greater. A strong correlation between electrical and acoustic signal intensities from discharge generated in the transformer oil was confirmed by the results reported here.

  • PDF

Development of Deterioration Detecting Sensor in Oil for Diagnosis of Oil-Filled Transformers (유입 변압기 진단을 위한 유중 열화 측정 센서의 개발)

  • Min, Kyeoung-Rae;Yoon, Yong-Han;Kim, Young-Chun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.128-130
    • /
    • 2000
  • This paper develops the deterioration detecting sensor in oil to monitor and diagnose oil-filled transformer more effectively. The on-line inspection of the oil-filled transformers used the temperature, the changes of the capacitance, the $tan{\delta}$ in oil. This sensor was designed based on the concentric cylindrical type so that it could be placed inside of the oil-filled transformer. And comparing to the existing system, it was proven to be appropriate. Establishment of the proposed sensor helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

A Study on Suggestion of Insulating Oil Ageing Degree in Pole-Transformer by Absorbance (흡광도법에 의한 주상변압기 절연유의 열화판정기준 설정에 관한 연구)

  • Lee, Dong-Zoon;Jung, Jong-Uk;Kim, Kyung-Hwa;Kwak, Hee-Ro;Yun, Yong-Ja
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1851-1853
    • /
    • 1996
  • In this paper the criteria for insulating oil condition of pole transformer were suggested by applying the UV-Visible spectrophotometric method. Ageing of insulating oil caused the change in absorbances of oil os well os the deterioration of electrical properties of oil. By comparing the electrical properties such as $tan{\delta}$ and breakdown voltage with the UV-Visible absorbances of oil, criteria for absorbance values determining oil condition were established. This UV-Visible spectrophotometric method might be applied in ageing analysis of oil and be expected to replace the current method.

  • PDF

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

Analysis of the polychlorinated biphenyls in transformer oils using peak matching method (피크패턴법을 이용한 절연유 중 PCBs 분석)

  • Shin, Sun Kyoung;Kim, Hye-Jin;Chung, David;Jeon, Tae Wan;Kim, Jin Kyoung;Park, Seok Un;Chung, Young Hee;Chung, Il Rok
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.410-418
    • /
    • 2005
  • PCBs had numerous uses such as hydraulic fluid, heat exchange fluid, sealant, lubricant, and carbonless copy paper. They are most likely found in electric utilities, power stations, industrial facilities, electronic manufacturing plants, petrochemical plants, railroad systems, electric equipment repair facilities, mining sites (active or abandoned), and military camps. Due to its outstanding chemical and thermal stabilities and electrical insulation properties, the commercial and industrial products of PCBs, such as Aroclors, Kaneclors, Clophens, Phenaclors etc., had been widely used as thermal oil and transformer oil from 1930s until the 1970s. The transformer oils were analyzed as a main source of polychlorinated biphenyls (PCBs) emission into the environment. Qualitative estimation of oil extracts as carried out with Aroclor 1242, 1248, 1254, 1260. The transformer oils contained the pure and mixed of Aroclor 1242, Aroclor 1254, and Aroclor 1260. Also, commercial screening kit of 20 ppm and 50 ppm were applied to the transformer oil samples.

A Study of Coupled Electromagnetic-Thermal Field Analysis for Temperature Rise Prediction of Power Transformer (전력용 변압기의 온도상승 예측을 위한 전자계-열계 결합해석기법 연구)

  • Ahn, Hyun-Mo;Kim, Min-Soo;Song, Jae-Sung;Hahn, Sung-Chin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1838-1845
    • /
    • 2011
  • This paper deals with coupled electromagnetic-thermal field analysis for thermal fluid analysis of oil immersed power transformer. Electric power losses are calculated from electromagnetic field analysis and are used as input source of thermal field analysis based on computational fluid dynamics(CFD). Particularly, In order to accurately predict the temperature rise in oil immersed power transformer, the thermal problem should be coupled with the electromagnetic problem. Moreover, to reduce analysis region, the heat transfer coefficient is applied to boundary surface of the power transformer model. The coupling method results are compared with the experimental values for verifying the validity of the analysis. The predicted temperature rises show good agreements with the experimental values.